AF09-30-10-13 100-250V50/60HZ-DC Contactor
- Manufactured by:
- ABB instrumentation
- Nuova Elva code
- 1SBL137001R1310
- Manufacturer code
- 1SBL137001R1310
- Availability
- Send request for quotation
The AF09-30-10-13 is a 3 pole - 690 V IEC or 600 UL contactor with 1 built-in auxiliary contact and screw terminals, controlling motors up to 4 kW / 400 V AC (AC-3) or 5 hp / 480 V UL and switching power circuits up to 25 A (AC-1) or 25 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
Specifications
Ordering | |
---|---|
Minimum Order Quantity | 1 piece |
Customs Tariff Number | 85364900 |
Dimensions | |
Product Net Width | 45 mm |
Product Net Depth / Length | 77 mm |
Product Net Height | 86 mm |
Product Net Weight | 0.27 kg |
Technical | |
Standards | IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14 |
Rated Operational Voltage | Auxiliary Circuit 690 VMain Circuit 690 V |
Rated Frequency (f) | Auxiliary Circuit 50 / 60 HzMain Circuit 50 / 60 Hz |
Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors q = 40 °C 35 Aacc. to IEC 60947-5-1, q = 40 °C 16 A |
Rated Operational Current AC-1 (Ie) | (690 V) 40 °C 25(690 V) 60 °C 25 A(690 V) 70 °C 22 |
Rated Operational Current AC-3 (Ie) | (415 V) 60 °C 9 A(440 V) 60 °C 9 A(500 V) 60 °C 9.5 A(690 V) 60 °C 7 A(380 / 400 V) 60 °C 9 A(220 / 230 / 240 V) 60 °C 9 A |
Rated Operational Power AC-3 (Pe) | (400 V) 4 kW(415 V) 4 kW(440 V) 4 kW(500 V) 5.5 kW(690 V) 5.5 kW(380 / 400 V) 4 kW(220 / 230 / 240 V) 2.2 kW |
Rated Operational Current AC-15 (Ie) | (500 V) 2 A(690 V) 2 A(24 / 127 V) 6 A(220 / 240 V) 4 A(400 / 440 V) 3 A |
Rated Short-time Withstand Current (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 Afor 0.1 s 140 Afor 1 s 100 A |
Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A |
Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour(AC-15) 1200 cycles per hour(AC-2 / AC-4) 300 cycles per hour(AC-3) 1200 cycles per hour(DC-13) 900 cycles per hour |
Rated Operational Current DC-13 (Ie) | (24 V) 6 A / 144 W(48 V) 2.8 A / 134 W(72 V) 1 A / 72 W(110 V) 0.55 A / 60 W(125 V) 0.55 A / 69 W(220 V) 0.27 A / 60 W(250 V) 0.27 A / 68 W(400 V) 0.15 A / 60 W(500 V) 0.13 A / 65 W(600 V) 0.1 A / 60 W |
Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 Vacc. to UL/CSA 600 V |
Rated Impulse Withstand Voltage (Uimp) | 6 kV |
Maximum Mechanical Switching Frequency | 3600 cycles per hour |
Rated Control Circuit Voltage (Uc) | 50 Hz 100 ... 250 V50 Hz / 60 Hz 100 ... 250 V60 Hz 100 ... 250 VDC Operation 100 ... 250 V |
Operate Time | Between Coil De-energization and NC Contact Closing 13 ... 98 msBetween Coil De-energization and NO Contact Opening 11 ... 95 msBetween Coil Energization and NC Contact Opening 38 ... 90 msBetween Coil Energization and NO Contact Closing 40 ... 95 ms |
Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.75 ... 6 mm²Flexible with Insulated Ferrule 1x 0.75 ... 4 mm²Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²Rigid 1/2x 1 ... 6 mm² |
Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Rigid 1/2x 1 ... 2.5 mm² |
Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²Rigid 1/2x 1 ... 2.5 mm² |
Wire Stripping Length | Auxiliary Circuit 10 mmControl Circuit 10 mmMain Circuit 10 mm |
Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 |
Terminal Type | Screw Terminals |
Number of Main Contacts NO | 3 |
Number of Main Contacts NC | 0 |
Number of Auxiliary Contacts NO | 1 |
Number of Auxiliary Contacts NC | 0 |
Technical UL/CSA | |
General Use Rating UL/CSA | (600 V AC) 25 A |
Horsepower Rating UL/CSA | (120 V AC) Single Phase 3/4 hp(200 ... 208 V AC) Three Phase 2 hp(220 ... 240 V AC) Three Phase 2 hp(240 V AC) Single Phase 1-1/2 hp(440 ... 480 V AC) Three Phase 5 hp(550 ... 600 V AC) Three Phase 7-1/2 hp |
Tightening Torque UL/CSA | Auxiliary Circuit 11 IAControl Circuit 11 IAMain Circuit 13 IA |
Environmental | |
Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 °CClose to Contactor without Thermal O/L Relay -40 ... +70 °CClose to Contactor for Storage -60 ... +80 °CNear Contactor for Operation in Free Air -40 ... +70 °C |
Climatic Withstand | Category B according to IEC 60947-1 Annex Q |
Maximum Operating Altitude Permissible | 3000 m |
Resistance to Vibrations acc. to IEC 60068-2-6 | 5 ... 300 Hz 4 g closed position / 2 g open position |
Resistance to Shock acc. to IEC 60068-2-27 | Closed, Shock Direction: B1 25 K40Open, Shock Direction: B1 5 K40Shock Direction: A 30 K40Shock Direction: B2 15 K40Shock Direction: C1 25 K40Shock Direction: C2 25 K40 |
RoHS Status | Following EU Directive 2011/65/EU |
Container Information | |
Package Level 1 Units | box 1 piece |
Package Level 1 Width | 87 mm |
Package Level 1 Depth / Length | 79 mm |
Package Level 1 Height | 47 mm |
Package Level 1 Gross Weight | 0.27 kg |
Package Level 1 EAN | 3471523110038 |
Package Level 2 Units | box 27 piece |
Package Level 2 Width | 250 mm |
Package Level 2 Depth / Length | 300 mm |
Package Level 2 Height | 315 mm |
Package Level 2 Gross Weight | 7.29 kg |
Package Level 3 Units | 1296 piece |
Classifications | |
Object Classification Code | Q |
ETIM 4 | EC000066 - Magnet contactor, AC-switching |
ETIM 5 | EC000066 - Magnet contactor, AC-switching |
eClass | V11.0 : 27371003 |
E-Number (Finland) | 3706201 |
E-Number (Sweden) | 3210009 |