AF52-30-00-13 100-250V50/60HZ-DC Contactor

Manufactured by:
ABB
Abb

9a8e57dfe5bfacd779e442f3bfbd196f5cbacb89 medium
Nuova Elva code
AF52300013
Manufacturer code
1SBL367001R1300
Availability
Send request for quotation

The AF52-30-00-13 is a 3 pole - 690 V IEC or 600 UL contactor with screw terminals, controlling motors up to 22 kW / 400 V AC (AC-3) or 40 hp / 480 V UL and switching power circuits up to 100 A (AC-1) or 80 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.

Specifications

Ordering

Minimum Order Quantity1 piece
Customs Tariff Number85364900

Dimensions

Product Net Width55 mm
Product Net Depth / Length111 mm
Product Net Height125.5 mm
Product Net Weight0.95 kg

Technical

Rated Operational VoltageMain Circuit 690 V
Rated Frequency (f)Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors q = 40 °C 105 A
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 100(690 V) 60 °C 80 A(690 V) 70 °C 70
Rated Operational Current AC-3 (Ie)(415 V) 60 °C 53 A(440 V) 60 °C 53 A(500 V) 60 °C 45 A(690 V) 60 °C 35 A(380 / 400 V) 60 °C 53 A(220 / 230 / 240 V) 60 °C 53 A
Rated Operational Power AC-3 (Pe)(400 V) 22 kW(415 V) 30 kW(440 V) 30 kW(500 V) 30 kW(690 V) 30 kW(380 / 400 V) 22 kW(220 / 230 / 240 V) 15 kW
Rated Short-time Withstand Current (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 Afor 1 s -empty- A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A
Maximum Electrical Switching Frequency(AC-1) 600 cycles per hour(AC-2 / AC-4) 150 cycles per hour(AC-3) 1200 cycles per hour
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 Vacc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)6 kV
Maximum Mechanical Switching Frequency3600 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 100 ... 250 V50 Hz / 60 Hz 100 ... 250 V60 Hz 100 ... 250 VDC Operation 100 ... 250 V
Operate TimeBetween Coil De-energization and NC Contact Closing 19 ... 105 msBetween Coil De-energization and NO Contact Opening 17 ... 100 msBetween Coil Energization and NC Contact Opening 38 ... 95 msBetween Coil Energization and NO Contact Closing 42 ... 100 ms
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 4 ... 35 mm²Flexible with Insulated Ferrule 1/2x 4 ... 35 mm²Rigid 1/2x 6 ... 3 5 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²Rigid 1/2x 1 ... 2.5 mm²
Wire Stripping LengthMain Circuit 16 mm
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Terminal TypeScrew Terminals
Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO0
Number of Auxiliary Contacts NC0

Technical UL/CSA

General Use Rating UL/CSA(600 V AC) 80 A
Horsepower Rating UL/CSA(120 V AC) Single Phase 3 hp(200 ... 208 V AC) Three Phase 15 hp(220 ... 240 V AC) Three Phase 20 hp(240 V AC) Single Phase 10 hp(440 ... 480 V AC) Three Phase 40 hp(550 ... 600 V AC) Three Phase 50 hp
Tightening Torque UL/CSAControl Circuit 11 IAMain Circuit 35 IA

Environmental

Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay -25 ... +60 °CClose to Contactor without Thermal O/L Relay -40 ... +70 °CClose to Contactor for Storage -60 ... +80 °C
Climatic WithstandCategory B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible3000 m
Resistance to Vibrations acc. to IEC 60068-2-65 ... 300 Hz 3 g closed position / 3 g open position
Resistance to Shock acc. to IEC 60068-2-27Closed, Shock Direction: A 25 K40Closed, Shock Direction: B1 25 K40Closed, Shock Direction: B2 15 K40Closed, Shock Direction: C1 25 K40Closed, Shock Direction: C2 25 K40Open, Shock Direction: B1 5 K40
RoHS StatusFollowing EU Directive 2011/65/EU

Container Information

Package Level 1 Unitsbox 1 piece
Package Level 1 Width150 mm
Package Level 1 Depth / Length150 mm
Package Level 1 Height97 mm
Package Level 1 Gross Weight1.05 kg
Package Level 1 EAN3471523132337
Package Level 2 Unitsbox 10 piece
Package Level 2 Width250 mm
Package Level 2 Depth / Length300 mm
Package Level 2 Height300 mm
Package Level 2 Gross Weight10.5 kg
Package Level 3 Units240 piece

Classifications

Object Classification CodeQ
ETIM 4EC000066 - Magnet contactor, AC-switching
ETIM 5EC000066 - Magnet contactor, AC-switching
eClassV11.0 : 27371003
E-Number (Finland)3707016
E-Number (Sweden)3210039

Docs


Frequently bought together


Other ABB items

Request a quote