GAF185-10-11 20-60V DC Contactor

Manufactured by:
ABB
Abb

57ce5c78f6a1c04c13cee275ee7d069429924206 medium
Nuova Elva code
GAF185101124
Manufacturer code
1SFL497025R7211
Availability
Standard lead time: 13 days

A 3-pole Contactor suitable for DC-1 applications where all three poles must be connected in series in a 1-pole configuration up to max 1000 VDC. Operated with wide control voltage range 20-60 V, DC

Specifications

Classifications

Object Classification CodeQ
ETIM 4EC002552 - Power contactor, DC switching
ETIM 5EC002552 - Power contactor, DC switching
ETIM 6EC002552 - Power contactor, DC switching
ETIM 7EC002552 - Power contactor, DC switching
UNSPSC39121529
IDEA Granular Category Code (IGCC)4755 >> Contactors

Container Information

Package Level 1 Height167 mm
Package Level 1 Gross Weight3.6 kg
Package Level 1 EAN7320500383766
Package Level 1 Unitsbox 1 piece
Package Level 1 Width178 mm
Package Level 1 Depth / Length232 mm

Technical UL/CSA

Maximum Operating Voltage UL/CSAMain Circuit 600 V
General Use Rating UL/CSA(1000 V DC) 250 A(440 V DC) 250 A(600 V DC) 250 A

Environmental

Ambient Air TemperatureOperation -40 ... +70 °CStorage -40 ... +70 °C
Maximum Operating Altitude Permissible3000 m
Resistance to Shock acc. to IEC 60068-2-27Shock Direction: A 5 K40Shock Direction: B1 5 K40Shock Direction: B2 5 K40Shock Direction: C1 5 K40Shock Direction: C2 5 K40
RoHS StatusFollowing EU Directive 2011/65/EU

Technical

Number of Main Contacts NO1
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC1
Rated Operational VoltageMain Circuit 1000 V
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors q = 40 °C 275 A
Rated Operational Current DC-1 (Ie)(1000 V) 3 Poles in Series, 40 °C 275 A(1000 V) 3 Poles in Series, 55 °C 250 A(1000 V) 3 Poles in Series, 70 °C 180 A(220 V) 3 Poles in Series, 40 °C 275 A(220 V) 3 Poles in Series, 55 °C 250 A(220 V) 3 Poles in Series, 70 °C 180 A(400 V) 3 Poles in Series, 40 °C 275 A(400 V) 3 Poles in Series, 55 °C 250 A(400 V) 3 Poles in Series, 70 °C 180 A(600 V) 3 Poles in Series, 40 °C 275 A(600 V) 3 Poles in Series, 55 °C 250 A(600 V) 3 Poles in Series, 70 °C 180 A
Rated Insulation Voltage (Ui)acc. to UL/CSA 1000 V
Rated Impulse Withstand Voltage (Uimp)Main Circuit 8 kV
Mechanical Durability5 million
Maximum Mechanical Switching Frequency300 cycles per hour
Coil Operating Limits(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)DC Operation 20 ... 60 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 12 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 12 V·AHolding at Max. Rated Control Circuit Voltage DC 3.5 WPull-in at Max. Rated Control Circuit Voltage 50 Hz 430 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 430 V·APull-in at Max. Rated Control Circuit Voltage DC 500 W
Connecting Capacity Main CircuitBar 24 mmRigid Al-Cable 25 ... 150 m²Rigid Cu-Cable 6 ... 185 m²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1x 0.75 ... 2.5Flexible with Insulated Ferrule 2x 0.75 ... 2.5Flexible 2x0.75 ... 2.5 m²Solid 2 x 1 ... 4 m²Stranded 2 x 1 .... 4 m²
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal TypeMain Circuit: Bars

Dimensions

Product Net Width111.5 mm
Product Net Depth / Length160 mm
Product Net Height196 mm
Product Net Weight3 kg

Ordering

Minimum Order Quantity1 piece
Customs Tariff Number85364900

Docs