NF22E-14 250-500V50/60HZ-DC Contactor Relay
- Manufactured by:
- ABB
NF contactor relays are used for switching auxiliary and control circuits. NF contactor relays include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...500 V 50/60 Hz or 20...500 V DC. NF contactor relays can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. NF contactor relays have built-in surge protection and do not require additional surge suppressors. - Poles: 4-pole contactor relays (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1 and including the "Mechanically Linked" symbol on the contactor relay side) - Control Circuit: AC or DC operated - Accessories: a wide range of Accessories is available.
Specifications
Ordering | |
---|---|
Minimum Order Quantity | 1 piece |
Customs Tariff Number | 85364900 |
Dimensions | |
Product Net Width | 45 mm |
Product Net Depth / Length | 77 mm |
Product Net Height | 86 mm |
Product Net Weight | 0.31 kg |
Technical | |
Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz |
Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-5-1, q = 40 °C 16 A |
Rated Operational Current AC-15 (Ie) | (500 V) 2 A(690 V) 2 A(24 / 127 V) 6 A(220 / 240 V) 4 A(400 / 440 V) 3 A |
Rated Short-time Withstand Current (Icw) | for 0.1 s 140 Afor 1 s 100 A |
Maximum Electrical Switching Frequency | (AC-15) 1200 cycles per hour(DC-13) 900 cycles per hour |
Rated Operational Current DC-13 (Ie) | (24 V) 6 A / 144 W(48 V) 2.8 A / 134 W(72 V) 1 A / 72 W(110 V) 0.55 A / 60 W(125 V) 0.55 A / 69 W(220 V) 0.27 A / 60 W(250 V) 0.27 A / 68 W(400 V) 0.15 A / 60 W(500 V) 0.13 A / 65 W(600 V) 0.1 A / 60 W |
Rated Insulation Voltage (Ui) | acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 Vacc. to UL/CSA 600 V |
Rated Impulse Withstand Voltage (Uimp) | 6 kV |
Maximum Mechanical Switching Frequency | 6000 cycles per hour |
Rated Control Circuit Voltage (Uc) | 50 Hz 250 ... 500 V50 Hz / 60 Hz 250 ... 500 V60 Hz 250 ... 500 VDC Operation 250 ... 500 V |
Operate Time | Between Coil De-energization and NC Contact Closing 13 ... 98 msBetween Coil De-energization and NO Contact Opening 11 ... 95 msBetween Coil Energization and NC Contact Opening 38 ... 90 msBetween Coil Energization and NO Contact Closing 40 ... 95 ms |
Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Rigid 1/2x 1 ... 2.5 mm² |
Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²Rigid 1/2x 1 ... 2.5 mm² |
Wire Stripping Length | Auxiliary Circuit 10 mmControl Circuit 10 mm |
Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
Terminal Type | Screw Terminals |
Number of Auxiliary Contacts NO | 2 |
Number of Auxiliary Contacts NC | 2 |
Standards | IEC 60947-5-1 and EN 60947-5-1, UL 508, CSA C22.2 N°14 |
Rated Operational Voltage | Auxiliary Circuit 690 VMain Circuit 690 V |
Technical UL/CSA | |
Tightening Torque UL/CSA | Auxiliary Circuit 11 IAControl Circuit 11 IA |
Environmental | |
Ambient Air Temperature | Close to Contactor for Storage -60 ... +80 °CNear Contactor for Operation in Free Air -40 ... +70 °C |
Climatic Withstand | Category B according to IEC 60947-1 Annex Q |
Maximum Operating Altitude Permissible | 3000 m |
Resistance to Vibrations acc. to IEC 60068-2-6 | 5 ... 300 Hz 4 g closed position / 2 g open position |
Resistance to Shock acc. to IEC 60068-2-27 | Closed, Shock Direction: B1 25 K40Open, Shock Direction: B1 5 K40Shock Direction: A 30 K40Shock Direction: B2 15 K40Shock Direction: C1 25 K40Shock Direction: C2 25 K40 |
RoHS Status | Following EU Directive 2011/65/EU |
Container Information | |
Package Level 1 Units | box 1 piece |
Package Level 1 Width | 87 mm |
Package Level 1 Depth / Length | 79 mm |
Package Level 1 Height | 47 mm |
Package Level 1 Gross Weight | 0.31 kg |
Package Level 1 EAN | 3471523100145 |
Package Level 2 Units | box 27 piece |
Package Level 2 Width | 250 mm |
Package Level 2 Depth / Length | 300 mm |
Package Level 2 Height | 315 mm |
Package Level 2 Gross Weight | 16.74 kg |
Package Level 3 Units | 1296 piece |
Classifications | |
Object Classification Code | K |
ETIM 4 | EC000196 - Contactor relay |
ETIM 5 | EC000196 - Contactor relay |
eClass | V11.0 : 27371003 |
E-Number (Finland) | 3706402 |
E-Number (Sweden) | 3211449 |