XT4N 160 TMD 20-300 3p F F
- Manufactured by:
- ABB
C.BREAKER TMAX XT4N 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 20-300 A
Specifications
Ordering | |
---|---|
EAN | 8015644019730 |
Minimum Order Quantity | 1 piece |
Customs Tariff Number | 85362090 |
Dimensions | |
Product Net Width | 105 mm |
Product Net Height | 160 mm |
Product Net Depth / Length | 82.5 mm |
Product Net Weight | 2.05 kg |
Container Information | |
Package Level 1 Depth / Length | 168 mm |
Package Level 1 Gross Weight | 2.5 kg |
Package Level 1 EAN | 8015644019730 |
Package Level 1 Units | 1 piece |
Package Level 1 Width | 145 mm |
Package Level 1 Height | 210 mm |
Additional Information | |
Circuit Breaker Type to be Associated | Power Distribution |
Current Type | AC/DC |
Electrical Durability | 120 cycles per hour8000 cycle |
Mechanical Durability | Nr. Operations 240 cycles per hourNr. Operations 25000 cycle |
Number of Poles | 3 |
Opening Time | CB with SOR 15 msCB with UVR 15 ms |
Order Multiple | 1 piece |
Product Main Type | SACE Tmax XT |
Product Name | Moulded Case Circuit Breaker |
Product Type | CB |
Rated Current (In) | 20 A |
Rated Frequency (f) | 50 / 60 Hz |
Rated Voltage (Ur) | 690 V |
Rated Impulse Withstand Voltage (Uimp) | 8 kV |
Rated Instantaneous Short-Circuit Current Setting (Ii) | 300 A |
Rated Insulation Voltage (Ui) | 1000 V |
Rated Operational Voltage | 690 V AC500 V DC |
Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 65 kA(230 V AC) 65 kA(240 V AC) 65 kA(380 V AC) 36 kA(415 V AC) 36 kA(440 V AC) 36 kA(500 V AC) 30 kA(525 V AC) 20 kA(690 V AC) 10 kA(250 V DC) 2 Poles in Series 36 kA(500 V DC) 2 Poles in Series 36 kA(500 V DC) 3 Poles in Series 36 kA |
Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 65 kA(230 V AC) 65 kA(240 V AC) 65 kA(380 V AC) 36 kA(415 V AC) 36 kA(440 V AC) 36 kA(500 V AC) 30 kA(525 V AC) 20 kA(690 V AC) 10 kA(250 V DC) 2 Poles in Series 36 kA(500 V DC) 2 Poles in Series 36 kA(500 V DC) 3 Poles in Series 36 kA |
Rated Uninterrupted Current (Iu) | 160 A |
Release Type | TM |
Setting Range | 14...20 A |
Standards | IEC |
Sub-type | XT4 |
Terminal Connection Type | Fixed Circuit-Breakers |
Version | F |
Classifications | |
ETIM 4 | EC000228 - Power circuit-breaker for trafo/generator/installation prot. |
ETIM 5 | EC000228 - Power circuit-breaker for trafo/generator/installation prot. |
ETIM 6 | EC000228 - Power circuit-breaker for trafo/generator/installation prot. |
ETIM 7 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
Object Classification Code | Q |
UNSPSC | 39120000 |
WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |