Enclosed Switch

Manufactured by:
OMRON
Omron

255ef5630b78345da0ec9a20b34f84e42409f53d medium
Price (VAT excluded)
€ 29.89
Nuova Elva code
D4MC2000
Manufacturer code
D4MC-2000
Availability
Standard lead time: 5 days

Standard sensitivity, IP67, Snap action, Self-reset mechanism, Single-Pole, Double-Throw type, SPDT, Hinge roller lever

Features

  • Electrical durability curve

Specifications

Amperage15 A
Frequency60 Hz
Number of Poles1

Ratings / Performance

Shape/StructureEnclosed Limit switches
Ratings (AC): Non-Inductive loadRated voltage: 125 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO)
Ratings (AC): Non-Inductive loadRated voltage: 250 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 2.5 A(NC) 1.25 A(NO)
Ratings (AC): Non-Inductive loadRated voltage: 480 VAC / Resistive load: 3 A(NC) 3 A(NO) / Lamp load: 1.5 A(NC) 0.75 A(NO)
Ratings (AC): Inductive loadRated voltage: 125 VAC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 5 A(NC) 2.5 A(NO)
Ratings (AC): Inductive loadRated voltage: 250 VAC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 3 A(NC) 1.5 A(NO)
Ratings (AC): Inductive loadRated voltage: 480 VAC / Inductive load: 2.5 A(NC) 2.5 A(NO) / Motor load: 1.5 A(NC) 0.75 A(NO)
Ratings (DC): Non-Inductive loadRated voltage: 8 VDC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO)
Ratings (DC): Non-Inductive loadRated voltage: 14 VDC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO)
Ratings (DC): Non-Inductive loadRated voltage: 30 VDC / Resistive load: 6 A(NC) 6 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO)
Ratings (DC): Non-Inductive loadRated voltage: 125 VDC / Resistive load: 0.5 A(NC) 0.5 A(NO) / Lamp load: 0.4 A(NC) 0.4 A(NO)
Service lifeGeneral type
Ratings (DC): Non-Inductive loadRated voltage: 250 VDC / Resistive load: 0.25 A(NC) 0.25 A(NO) / Lamp load: 0.2 A(NC) 0.2 A(NO)
Ratings (DC): Inductive loadRated voltage: 8 VDC / Inductive load: 6 A(NC) 6 A(NO) / Motor load: 5 A(NC) 2.5 A(NO)
Ratings (DC): Inductive loadRated voltage: 14 VDC / Inductive load: 6 A(NC) 6 A(NO) / Motor load: 5 A(NC) 2.5 A(NO)
Ratings (DC): Inductive loadRated voltage: 30 VDC / Inductive load: 5 A(NC) 5 A(NO) / Motor load: 5 A(NC) 2.5 A(NO)
Ratings (DC): Inductive loadRated voltage: 125 VDC / Inductive load: 0.05 A(NC) 0.05 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO)
Ratings (DC): Inductive loadRated voltage: 250 VDC / Inductive load: 0.03 A(NC) 0.03 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO)
Inrush currentNC: 30 A
Inrush currentNO: 15 A
Ambient temperatureOperating: -10 to 80 °C
Ambient humidityOperating: 35 to 95%
Operating mechanismSnap action
Permissible operating speed0.05 mm/s to 0.5 m/s
Permissible operating frequency (Mechanically)120 operations / 1 minute Max.
Permissible operating frequency (Electrically)20 operations / 1 minute Max.
Contact resistance15 mOhm Max. (Initial value)
Contact resistance(Measuring method is contact resistance meter.)
Insulation resistanceBetween each terminal of the same polarities: 100 MΩ
Insulation resistanceBetween live-metallic part and ground: 100 MΩ
Insulation resistanceBetween each terminal and non-live-metallic part: 100 MΩ
Insulation resistance(at 500 VDC Megger)
Dielectric strengthBetween each terminal of the same polarities: 1000 V
ActuatorHinge roller lever
Dielectric strengthBetween live-metallic part and ground: 2000 V
Dielectric strengthBetween each terminal and non-live-metallic part: 2000 V
Dielectric strength(50/60 Hz for 1 min)
Durability (Mechanically)10,000,000 operations Min. (No load)
Durability (Mechanically)(Temperature, Humidity conditions: 20 +/- 2 CEL, 65 +/- 5 %RH)
Durability (Electrically)500,000 operations Min. (Resistive load 10 A at 125 VAC) * When operate the actuator with the specified value of the Over Travel. (Resistive load 10 A at 125 VAC)
Durability (Electrically)(Temperature, Humidity conditions: 20 +/- 2 CEL, 65 +/- 5 %RH)
Vibration resistance (Malfunction)Vibration frequency range: 10 to 55 Hz, Double amplitude: 1.5 mm, Contact opening: 1 ms Max. at the free position and the total travel position.
Shock resistance (Destruction)1,000 m/s2
Shock resistance (Malfunction)Contact opening is 1 ms Max. at the free position and the total travel position at 100 m/s2.
Frequency50/60 Hz
Degree of protectionIEC60529 (JEM): IP67
Mounting specificationSide mounting
Weight88g
Operating Force (OF)Standard value Max. 1.96 N
Release Force (RF)Standard value Min. 0.39 N
Over-Travel (OT)Standard value 5 mm Min.
Movement Differential (MD)Standard value 3 mm Max.
Operating Position (OP)Standard value 40 +/- 1 mm
Free Position (FP)Standard value 51 mm Max.
Switching mechanismSelf-reset mechanism
Contact configurationSingle-Pole, Double-Throw type
Contact formSPDT
LoadGeneral load

Docs


Frequently bought together


Other OMRON items

Request a quote