Standard sensitivity, IP67, Snap action, Self-reset mechanism, Single-Pole, Double-Throw type, SPDT, Hinge roller lever
Features
Electrical durability curve
Specifications
Amperage | 15 A |
---|---|
Frequency | 60 Hz |
Number of Poles | 1 |
Ratings / Performance | |
Shape/Structure | Enclosed Limit switches |
Ratings (AC): Non-Inductive load | Rated voltage: 125 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO) |
Ratings (AC): Non-Inductive load | Rated voltage: 250 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 2.5 A(NC) 1.25 A(NO) |
Ratings (AC): Non-Inductive load | Rated voltage: 480 VAC / Resistive load: 3 A(NC) 3 A(NO) / Lamp load: 1.5 A(NC) 0.75 A(NO) |
Ratings (AC): Inductive load | Rated voltage: 125 VAC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 5 A(NC) 2.5 A(NO) |
Ratings (AC): Inductive load | Rated voltage: 250 VAC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 3 A(NC) 1.5 A(NO) |
Ratings (AC): Inductive load | Rated voltage: 480 VAC / Inductive load: 2.5 A(NC) 2.5 A(NO) / Motor load: 1.5 A(NC) 0.75 A(NO) |
Ratings (DC): Non-Inductive load | Rated voltage: 8 VDC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO) |
Ratings (DC): Non-Inductive load | Rated voltage: 14 VDC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO) |
Ratings (DC): Non-Inductive load | Rated voltage: 30 VDC / Resistive load: 6 A(NC) 6 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO) |
Ratings (DC): Non-Inductive load | Rated voltage: 125 VDC / Resistive load: 0.5 A(NC) 0.5 A(NO) / Lamp load: 0.4 A(NC) 0.4 A(NO) |
Service life | General type |
Ratings (DC): Non-Inductive load | Rated voltage: 250 VDC / Resistive load: 0.25 A(NC) 0.25 A(NO) / Lamp load: 0.2 A(NC) 0.2 A(NO) |
Ratings (DC): Inductive load | Rated voltage: 8 VDC / Inductive load: 6 A(NC) 6 A(NO) / Motor load: 5 A(NC) 2.5 A(NO) |
Ratings (DC): Inductive load | Rated voltage: 14 VDC / Inductive load: 6 A(NC) 6 A(NO) / Motor load: 5 A(NC) 2.5 A(NO) |
Ratings (DC): Inductive load | Rated voltage: 30 VDC / Inductive load: 5 A(NC) 5 A(NO) / Motor load: 5 A(NC) 2.5 A(NO) |
Ratings (DC): Inductive load | Rated voltage: 125 VDC / Inductive load: 0.05 A(NC) 0.05 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO) |
Ratings (DC): Inductive load | Rated voltage: 250 VDC / Inductive load: 0.03 A(NC) 0.03 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO) |
Inrush current | NC: 30 A |
Inrush current | NO: 15 A |
Ambient temperature | Operating: -10 to 80 °C |
Ambient humidity | Operating: 35 to 95% |
Operating mechanism | Snap action |
Permissible operating speed | 0.05 mm/s to 0.5 m/s |
Permissible operating frequency (Mechanically) | 120 operations / 1 minute Max. |
Permissible operating frequency (Electrically) | 20 operations / 1 minute Max. |
Contact resistance | 15 mOhm Max. (Initial value) |
Contact resistance | (Measuring method is contact resistance meter.) |
Insulation resistance | Between each terminal of the same polarities: 100 MΩ |
Insulation resistance | Between live-metallic part and ground: 100 MΩ |
Insulation resistance | Between each terminal and non-live-metallic part: 100 MΩ |
Insulation resistance | (at 500 VDC Megger) |
Dielectric strength | Between each terminal of the same polarities: 1000 V |
Actuator | Hinge roller lever |
Dielectric strength | Between live-metallic part and ground: 2000 V |
Dielectric strength | Between each terminal and non-live-metallic part: 2000 V |
Dielectric strength | (50/60 Hz for 1 min) |
Durability (Mechanically) | 10,000,000 operations Min. (No load) |
Durability (Mechanically) | (Temperature, Humidity conditions: 20 +/- 2 CEL, 65 +/- 5 %RH) |
Durability (Electrically) | 500,000 operations Min. (Resistive load 10 A at 125 VAC) * When operate the actuator with the specified value of the Over Travel. (Resistive load 10 A at 125 VAC) |
Durability (Electrically) | (Temperature, Humidity conditions: 20 +/- 2 CEL, 65 +/- 5 %RH) |
Vibration resistance (Malfunction) | Vibration frequency range: 10 to 55 Hz, Double amplitude: 1.5 mm, Contact opening: 1 ms Max. at the free position and the total travel position. |
Shock resistance (Destruction) | 1,000 m/s2 |
Shock resistance (Malfunction) | Contact opening is 1 ms Max. at the free position and the total travel position at 100 m/s2. |
Frequency | 50/60 Hz |
Degree of protection | IEC60529 (JEM): IP67 |
Mounting specification | Side mounting |
Weight | 88g |
Operating Force (OF) | Standard value Max. 1.96 N |
Release Force (RF) | Standard value Min. 0.39 N |
Over-Travel (OT) | Standard value 5 mm Min. |
Movement Differential (MD) | Standard value 3 mm Max. |
Operating Position (OP) | Standard value 40 +/- 1 mm |
Free Position (FP) | Standard value 51 mm Max. |
Switching mechanism | Self-reset mechanism |
Contact configuration | Single-Pole, Double-Throw type |
Contact form | SPDT |
Load | General load |