FO converters - PSI-MOS-PROFIB/FO 850 E - 2708274
- Manufactured by:
- PHOENIX CONTACT
- Price (VAT excluded)
- € 1050.76
- Nuova Elva code
- 2708274
- Manufacturer code
- 2708274
- Availability
- Send request for quotation
FO converter with integrated optical diagnostics, alarm contact, for PROFIBUS up to 12 Mbps, terminal device with one FO interface (BFOC), 850 nm, for PCF/fiberglass cable (multimode)
Features
Connections can be plugged in using a COMBICON screw terminal block
Can be combined with the PSI copper repeater in a modular way using DIN rail connectors
Supply voltage and data signals routed through via DIN rail connectors
Automatic data rate detection or fixed data rate setting via DIP switches
High-quality electrical isolation between all interfaces (PROFIBUS // fiber optic ports // power supply // DIN rail connector)
Redundant power supply possible by means of optional system power supply unit
Approved for use in zone 2
Integrated optical diagnostics for continuous monitoring of fiber optic paths
Intrinsically safe fiber optic interface (Ex op is) for direct connection to devices in zone 1
Floating switch contact for leading alarm generation in relation to critical fiber optic paths
Suitable for all data rates up to 12 Mbps
Bit retiming for any cascading depth
Shipbuilding approval in accordance with DNV GL
cULus Listed
EAC
cULus Recognized
DNV GL
UL Listed
cUL Listed
UL Recognized
cUL Recognized
Specifications
Depth | 106 mm |
---|---|
Height | 99 mm |
Width | 35 mm |
Conformance/approvals | |
Designation | CE |
Identification | CE-compliant |
Designation | EAC |
Identification | EAC |
Identification | II 3 G Ex nA nC IIC T4 Gc X |
Additional text | Please follow the special installation instructions in the documentation! |
Designation | ATEX |
Identification | II (2) G [Ex op is Gb] IIC |
Identification | II (2) D [Ex op is Db] IIIC |
Certificate | PTB 06 ATEX 2042 U |
Designation | UL, USA/Canada |
Identification | Class I, Zone 2, AEx nc IIC T5 |
Identification | Class I, Zone 2, Ex nC nL IIC T5 X |
Identification | Class I, Div. 2, Groups A, B, C, D |
Designation | PTB |
Designation | PROFIBUS approval |
Additional text | PROFIBUS-Center Netherlands |
Designation | Corrosive gas test |
Identification | ISA-S71.04-1985 G3 Harsh Group A |
Designation | Shipbuilding |
Identification | DNV GL |
Temperature | B |
Humidity | A |
Vibration | A |
EMC | B |
Enclosure | Required protection according to the Rules shall be provided upon installation on board |
Interfaces | |
Interface 1 | PROFIBUS acc. to IEC 61158, RS-485 2-wire, half duplex, automatic control |
Interface | PROFIBUS |
Operating mode | Semi-duplex |
Connection method | D-SUB-9 female connector |
File format/coding | UART (11 Bit, NRZ) |
Data direction switching | Automatic control |
Transmission medium | Copper |
Transmission length | ≤ 1200 m (depending on the data rate, with shielded, twisted pair data cable) |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 14 |
Serial transmission speed | ≤ 12 Mbps |
Ambient conditions | |
Noise immunity | EN 61000-6-2:2005 |
Ambient temperature (operation) | -20 °C - 60 °C |
Ambient temperature (storage/transport) | -40 °C - 85 °C |
Permissible humidity (operation) | 30 % - 95 % (non-condensing) |
Altitude | ≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation) |
Degree of protection | IP20 |
Optical interface FO | |
No. of channels | 1 |
Transmit capacity, minimum | -4.2 dBm (200/230 µm) |
Transmit capacity, minimum | -17.8 dBm (50/125 µm) |
Transmit capacity, minimum | -14.6 dBm (62,5/125 µm) |
Minimum receiver sensitivity | -30 dBm (50/125 µm) |
Overrange receiver | -3 dBm (200/230 µm) |
Wavelength | 850 nm |
Transmission length incl. 3 dB system reserve | 2600 m (with F-G 50/125 2.5 dB/km) |
Transmission length incl. 3 dB system reserve | 3300 m (with F-G 62,5/125 3.0 dB/km) |
Transmission length incl. 3 dB system reserve | 800 m (With F-K 200/230 10 dB/km with quick mounting connector) |
Transmission medium | PCF fiber |
Transmission medium | Multi-mode fiberglass |
Transmission protocol | Protocol-transparent to the RS-485 interface |
Connection method | B-FOC (ST®) |
Environmental Product Compliance | |
REACh SVHC | Lead 7439-92-1 |
China RoHS | Environmentally Friendly Use Period = 50 years |
China RoHS | For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration' |
Standards and Regulations | |
Noise immunity | EN 61000-6-2:2005 |
Free from substances that could impair the application of coating | according to P-VW 3.10.7 57 65 0 VW-AUDI-Seat central standard |
Connection in acc. with standard | CUL |
Standards/regulations | EN 61000-4-2 |
Contact discharge | ± 6 kV |
Standards/regulations | EN 61000-4-3 |
Standards/regulations | EN 61000-4-4 |
Comments | Criterion B |
Standards/regulations | EN 61000-4-5 |
Signal | ± 1 kV |
Standards/regulations | EN 55011 |
Standards/regulations | EN 61000-4-6 |
Shock | 15g in all directions in acc. with IEC 60068-2-27 |
Vibration (operation) | in acc. with IEC 60068-2-6: 5g, 150 Hz |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Type of test | Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 |
Test result | 5g, 10...150 Hz, 2.5 h, in XYZ direction |
Type of test | Shock in acc. with EN 60068-2-27/IEC 60068-2-27 |
Test result | 15g, 11 ms period, half-sine shock pulse |
Noise emission | EN 55011 |
Dimensions | |
Width | 35 mm |
Height | 99 mm |
Depth | 106 mm |
Digital outputs | |
Output name | Relay output |
Output description | Alarm output |
Number of outputs | 1 |
Maximum switching voltage | 60 V DC |
Maximum switching voltage | 42 V AC |
Limiting continuous current | 0.46 A |
Power supply | |
Nominal supply voltage | 24 V DC (With UL approval) |
Supply voltage range | 18 V DC - 30 V DC |
Max. current consumption | 130 mA |
Typical current consumption | 120 mA (24 V DC) |
Connection method | COMBICON plug-in screw terminal block |
Note | |
Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |