Distributed I/O device - FLS PB M12 DI 8 M12 - 2736123
- Manufactured by:
- PHOENIX CONTACT
The stand-alone device for PROFIBUS has 8 digital inputs. The M12 connection is established using fast connection technology. The 24 V DC supply is protected against short circuit and overload. The nominal current of the device is 600 mA.
Features
Flexible power supply concept
Diagnostic and status indicators
SPEEDCON fast locking system
Short-circuit and overload protection
Consistent connection via M12 connectors
Directly accessible address encoding switch
cULus Recognized
PROFIBUS
EAC
UL Recognized
cUL Recognized
Specifications
Depth | 44.5 mm |
---|---|
Height | 161 mm |
Width | 60 mm |
Standards and Regulations | |
Mechanical tests | Shock in acc. with EN 60068-2-27/IEC 60068-2-27 Load 30g, half sine wave, positive and negative per direction |
Mechanical tests | Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g in each space direction |
Connection in acc. with standard | CUL |
Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
Environmental Product Compliance | |
REACh SVHC | Lead 7439-92-1 |
China RoHS | Environmentally Friendly Use Period = 50 years |
China RoHS | For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration' |
Dimensions | |
Width | 60 mm |
Height | 161 mm |
Depth | 44.5 mm |
Drill hole spacing | 151 mm |
Digital inputs | |
Input name | Digital inputs |
Description of the input | IEC 61131-2 type 1 |
Connection method | M12 connector |
Connection technology | 2, 3, 4-wire |
Number of inputs | 8 |
Protective circuit | Reverse polarity protection |
Nominal input voltage UIN | 24 V DC |
Filter time | 3 ms |
Input voltage | 24 V DC |
Input voltage range "0" signal | -30 V DC - 5 V DC |
Input voltage range "1" signal | 13 V DC - 30 V DC |
Interfaces | |
Designation | PROFIBUS DP |
Connection method | 2x M12 connectors, B-coded |
Designation connection point | Copper cable |
Transmission speed | 9.6 kbps - 12 Mbps (Automatic baud rate detection) |
Transmission physics | PROFIBUS-DP-compliant copper cable |
Address area assignment | 1 - 99, can be set |
Number of positions | 5 |
Ambient conditions | |
Air pressure (operation) | 80 kPa - 106 kPa (up to 2000 m above sea level) |
Air pressure (storage/transport) | 70 kPa - 106 kPa (up to 3000 m above sea level) |
Degree of protection | IP65/IP67 |
Ambient temperature (operation) | -25 °C - 60 °C |
Ambient temperature (storage/transport) | -25 °C - 85 °C |
Permissible humidity (storage/transport) | 95 % |
Fieldline potentials | |
Voltage supply UL | 24 V DC |
Power supply at UL | max. 4 A |
Current consumption from UL | typ. 35 mA |
Current consumption from UL | max. 100 mA |
Voltage supply US | 24 V DC |
Power supply at US | max. 4 A |
Current consumption from US | typ. 5 mA (plus sensor current) |
Current consumption from US | max. 700 mA |
Power supply for module electronics | |
Connection method | M12 connector, (A-coded) |
Designation | UL |
Supply voltage | 24 V DC |
Supply voltage range | 18 V DC - 30 V DC (including ripple) |
Electrical isolation | |
Test section | 24 V supply (bus logics) / Bus connection |
Test section | 24 V supply (bus logics) / FE 500 V AC 50 Hz 1 min. |
Test section | 24 V supply (bus logics) / Digital inputs (sensor supply) 500 V AC 50 Hz 1 min. |
Test section | Bus connection / FE 500 V AC 50 Hz 1 min. |
Test section | Bus connection / Digital inputs (sensor supply) 500 V AC 50 Hz 1 min. |
Test section | FE / Digital inputs (sensor supply) 500 V AC 50 Hz 1 min. |
Note | |
Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |