Distributed I/O device - FLM DI 16 M12 - 2736835
- Manufactured by:
- PHOENIX CONTACT
The local bus device has digital inputs. Functions: 16 digital inputs, 3 ms filter time, 500 kbaud/2 Mbaud selection, channel-specific diagnostics, short-circuit and overload protection, 1.2 A nominal current, M12 fast connection technology.
Features
Flexible power supply concept
Diagnostic and status indicators
SPEEDCON fast locking system
Short-circuit and overload protection
Consistent connection via M12 connectors
EAC
cULus Recognized
UL Recognized
cUL Recognized
Specifications
Depth | 50 mm |
---|---|
Height | 178 mm |
Width | 70 mm |
Dimensions | |
Width | 70 mm |
Height | 178 mm |
Depth | 50 mm |
Drill hole spacing | 168 mm |
Digital inputs | |
Input name | Digital inputs |
Description of the input | IEC 61131-2 type 1 |
Connection method | M12 connector |
Connection technology | 2, 3, 4-wire |
Number of inputs | 16 |
Protective circuit | Reverse polarity protection |
Nominal input voltage UIN | 24 V DC |
Filter time | 3 ms |
Input voltage | 24 V DC |
Input voltage range "0" signal | -30 V DC - 5 V DC |
Input voltage range "1" signal | 13 V DC - 30 V DC |
Delay at signal change from 0 to 1 | 3.1 ms |
Delay at signal change from 1 to 0 | 4.1 ms |
Interfaces | |
Designation | Fieldline local bus |
Connection method | M12 connector, B-coded |
Designation connection point | Copper cable |
Transmission speed | 500 kbps / 2 Mbps |
Number of positions | 5 |
Electrical isolation | |
Test section | To I/O 500 V AC |
Ambient conditions | |
Air pressure (storage/transport) | 70 kPa - 106 kPa (up to 3000 m above sea level) |
Degree of protection | IP65/IP67 |
Ambient temperature (operation) | -25 °C - 60 °C |
Ambient temperature (storage/transport) | -25 °C - 85 °C |
Permissible humidity (storage/transport) | 95 % |
Air pressure (operation) | 80 kPa - 106 kPa (up to 2000 m above sea level) |
Fieldline potentials | |
Voltage supply UL | 24 V DC |
Power supply at UL | max. 4 A |
Current consumption from UL | max. 50 mA (At 2 Mbaud) |
Current consumption from UL | typ. 40 mA (At 2 Mbaud) |
Current consumption from UL | max. 50 mA (At 500 kBaud) |
Current consumption from UL | typ. 35 mA (At 500 kBaud) |
Voltage supply US | 24 V DC |
Power supply at US | max. 4 A |
Current consumption from US | typ. 5 mA (plus power supply for sensors) |
Current consumption from US | max. 1.2 A |
Environmental Product Compliance | |
REACh SVHC | Lead 7439-92-1 |
China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
China RoHS | No hazardous substances above threshold values |
Power supply for module electronics | |
Connection method | M12 connector |
Designation | UL |
Supply voltage | 24 V DC |
Supply voltage range | 18 V DC - 30 V DC (including ripple) |
Standards and Regulations | |
Connection in acc. with standard | CUL |
Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
Note | |
Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |