Ex i measuring transducer repeater power supply, 2-channel; HART-transparent. Supplies Ex i 2-conductor measuring transducers and transmits the 4…20 mA signal from the Ex area to the safe area. 5-way electrical isolation, screw connection, up to SIL 3, PL.
Features
2-channel
4 mA ... 20 mA input, intrinsically safe, [Ex ia], powered
Output 4 mA ... 20 mA, active
HART-compatible
Error indication according to NAMUR NE 43
Up to SIL 3 according to IEC/EN 61508
5-way electrical isolation
Power supply possible via DIN rail connector
Installation in Ex zone 2 permitted
Plug-in connection terminal blocks, screw connection technology, with integrated sockets for HART communicators
Housing width: 12.5 mm
Minimal power dissipation
High transmission accuracy
cULus Listed
EAC Ex
Functional Safety
IECEx
ATEX
KC-s
UL Listed
cUL Listed
Specifications
Depth | 113.7 mm |
---|---|
Height | 112.5 mm |
Strip Length | 7 mm |
Width | 12.5 mm |
Ambient conditions | |
Noise immunity | EN 61000-6-2 When being exposed to interference, there may be minimal deviations. |
Ambient temperature (operation) | -20 °C - 60 °C (Any mounting position) |
Ambient temperature (storage/transport) | -40 °C - 80 °C |
Maximum altitude | ≤ 2000 m |
Permissible humidity (operation) | 10 % - 95 % (non-condensing) |
Degree of protection | IP20 (not assessed by UL) |
Output data | |
Signal output | Current output |
Current output signal | 4 mA - 20 mA (active) |
Transmission Behavior | 1:1 to input signal |
Load/output load current output | ≤ 450 Ω (20 mA) |
Load/output load current output | ≤ 375 Ω (24 mA) |
Output behavior in the event of an error | < 3.6 mA (In the event of cable break at the input (as per NE 43)) |
Output behavior in the event of an error | > 22.5 mA (In the event of cable short circuit at the input (as per NE 43)) |
Standards and Regulations | |
Electromagnetic compatibility | Conformance with EMC directive |
Noise emission | EN 61000-6-4 |
Conformance | CE-compliant, additionally EN 61326 |
ATEX | II (1) G [Ex ia Ga] IIC |
ATEX | II (1) D [Ex ia Da] IIIC |
ATEX | II 3(1) G Ex nA [ia Ga] IIC T4 Gc |
IECEx | [Ex ia Ga] IIC |
IECEx | [Ex ia Da] IIIC |
IECEx | Ex nA [ia Ga] IIC T4 Gc |
UL, USA/Canada | Class I Div 2; IS for Class I, II, III Div 1 |
DNV GL-Temperature | B |
DNV GL-Humidity | B |
DNV GL-Vibration | A |
DNV GL-EMC | A |
DNV GL-Enclosure | Required protection according to the Rules shall be provided upon installation on board |
Group | IIC |
Group | IIB |
Environmental Product Compliance | |
REACh SVHC | Lead 7439-92-1 |
China RoHS | Environmentally Friendly Use Period = 50 years |
China RoHS | For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration' |
Dimensions | |
Width | 12.5 mm |
Height | 112.5 mm |
Depth | 113.7 mm |
Safety data | |
Max. external capacitance Co | 510 nF |
Max. external capacitance Co | 660 nF |
Max. external inductivity Lo | 100 µH |
Safety-related maximum voltage Um | 253 V AC (125 V DC) |
Max. output voltage Uo | 25.2 V |
Max. output current Io | 93 mA |
Max. output power Po | 587 mW |
Group | IIC |
Max. external inductivity Lo | 2 mH |
Max. external capacitance Co | 107 nF |
Max. external capacitance Co | 49 nF |
Additional text | mixed circuit |
Max. external inductivity Lo | 1 mH |
Max. external capacitance Co | 63 nF |
Max. external inductivity Lo | 500 µH |
Max. external capacitance Co | 80 nF |
Max. external inductivity Lo | 200 µH |
Group | IIB |
Max. external inductivity Lo | 4 mH |
Max. external capacitance Co | 820 nF |
Additional text | simple circuit |
Max. external capacitance Co | 370 nF |
Max. external capacitance Co | 430 nF |
Connection data | |
Connection method | Screw connection |
Stripping length | 7 mm |
Screw thread | M3 |
Conductor cross section solid | 0.2 mm² - 2.5 mm² |
Conductor cross section flexible | 0.2 mm² - 2.5 mm² |
Conductor cross section AWG | 24 - 14 |
Torque | 0.5 Nm - 0.6 Nm |
Connection data 2 | |
Connection name | Test socket |
Max. diameter | 2.3 mm |
Input data | |
Signal input | Intrinsically safe |
Current input signal | 4 mA - 20 mA |
Transmitter supply voltage | > 16 V (20 mA) |
Underload/overload signal range | 0 mA - 24 mA |
Power supply | |
Nominal supply voltage | 24 V DC |
Supply voltage range | 19.2 V DC - 30 V DC (24 V DC -20%...+25%) |
Max. current consumption | < 100 mA (24 V / 20 mA) |
Power dissipation | < 1.4 W (at 24 V DC / 20 mA) |
Data communication (bypass) | |
HART function | Yes |
Protocols supported | HART |
Note | |
Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |