Power supply unit 2866747

Manufactured by:
PHOENIX CONTACT
Phoenix contact

D88e7354451921ad1cd2376f39a4b10e7188e93c medium
Price (VAT excluded)
€ 183.56
Nuova Elva code
2866747
Manufacturer code
2866747
Availability
Send request for quotation

Primary-switched QUINT POWER power supply for DIN rail mounting with SFB (Selective Fuse Breaking) Technology, input: 1-phase, output: 24 V DC/3.5 A

Features

  • Reliable starting of difficult loads with the static POWER BOOST power reserve with up to 1.5 times the nominal current permanently

  • Fast tripping of standard circuit breakers with dynamic power reserve SFB (selective fuse breaking) technology with up to 6 times the nominal current for 12 ms

  • For superior system availability

  • Preventive function monitoring

  • cULus Listed

  • cULus Listed

  • SEMI F47

  • EAC

  • cULus Recognized

  • EAC

  • LR

  • RINA

  • NK

  • DeviceNet

  • DNV GL

  • IECEE CB Scheme

  • ABS

  • CSA

  • UL Listed

  • cUL Listed

  • UL Listed

  • cUL Listed

  • UL Recognized

  • cUL Recognized

  • BV

Specifications

Height130 mm
Operating Temperature-25 °C
Protection RatingIP20
Width32 mm

Output data

Nominal output voltage24 V DC ±1 %
Setting range of the output voltage (U<sub>Set</sub>)18 V DC - 29.5 V DC (> 24 V DC, constant capacity restricted)
Nominal output current (I<sub>N</sub>)3.5 A (-25 °C - 60 °C, UOUT = 24 V DC)
POWER BOOST (I<sub>Boost</sub>)4 A (-25°C - 40°C permanent, UOUT = 24 V DC )
Selective Fuse Breaking (I<sub>SFB</sub>)15 A (12 ms)
Derating60 °C - 70 °C (2.5%/K)
Connection in parallelYes, for redundancy and increased capacity
Connection in seriesyes
Feedback resistancemax. 35 V DC
Protection against surge voltage on the output< 35 V DC
Control deviation< 1 % (change in load, static 10 % - 90 %)
Control deviation< 2 % (change in load, dynamic 10 % - 90 %)
Control deviation< 0.1 % (change in input voltage ±10 %)
Residual ripple< 50 mVPP (with nominal values)
Output power84 W
Typical response time< 0.05 s
Maximum power dissipation in no-load condition3.5 W
Power loss nominal load max.11 W

Standards and Regulations

Frequency range1.4 GHz - 2 GHz
Test field strength3 V/m (Test Level 2)
Standards/regulationsEN 61000-4-4
CommentsCriterion B
Standards/regulationsEN 61000-6-3
Standards/regulationsEN 61000-4-6
Frequency range0.15 MHz - 80 MHz
Voltage10 V (Test Level 3)
Low Voltage DirectiveConformance with LV directive 2006/95/EC
Standard - Electrical safetyIEC 60950-1/VDE 0805 (SELV)
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)
Standard – Safety extra-low voltageIEC 60950-1 (SELV) and EN 60204-1 (PELV)
Standard - Safe isolationDIN VDE 0100-410
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipmentEN 50178
Standard – Limitation of mains harmonic currentsEN 61000-3-2
Standard - Equipment safetyBG (design tested)
Standard - Approval for medical useIEC 60601-1, 2 x MOOP
Shipbuilding approvalDNV GL (EMC A), ABS, LR, RINA, NK, BV
UL approvalsUL Listed UL 508
UL approvalsUL/C-UL Recognized UL 60950-1
UL approvalsUL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
DeviceNet approvalDeviceNet™ Power Supply Conformance Tested
Shock18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation)< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
Vibration (operation)15 Hz - 150 Hz, 2.3g, 90 min.
Approval - requirement of the semiconductor industry with regard to mains voltage dipsSEMI F47-0706 Compliance Certificate
Information technology equipment - safety (CB scheme)CB Scheme
Rail applicationsEN 50121-4
Overvoltage category (EN 62477-1)III
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Noise emissionEN 55011 (EN 55022)
Noise immunityEN 61000-6-2:2005
Connection in acc. with standardCSA
Standards/regulationsEN 61000-4-2
Contact discharge4 kV (Test Level 2)
Standards/regulationsEN 61000-4-3
Frequency range80 MHz - 1 GHz
Test field strength10 V/m (Test Level 3)

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 25;
China RoHSFor details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Dimensions

Width32 mm
Height130 mm
Depth125 mm
Width with alternative assembly122 mm
Height with alternative assembly130 mm
Depth with alternative assembly35 mm

Input data

Nominal input voltage range100 V AC - 240 V AC
Input voltage range85 V AC - 264 V AC
Input voltage range90 V DC - 350 V DC
Dielectric strength maximum300 V AC
AC frequency range45 Hz - 65 Hz
Frequency range DC0 Hz
Discharge current to PE< 3.5 mA
Current consumption1.4 A (120 V AC)
Current consumption0.8 A (230 V AC)
Current consumption0.9 A (110 V DC)
Current consumption0.4 A (220 V DC)
Nominal power consumption180 VA
Inrush surge current< 20 A (typical)
Mains bufferingtyp. 20 ms (120 V AC)
Mains bufferingtyp. 80 ms (230 V AC)
Input fuse5 A (slow-blow, internal)
Choice of suitable circuit breakers6 A - 20 A (AC: Characteristics B, C, D, K)
Type of protectionTransient surge protection
Protective circuit/componentVaristor

Connection data, input

Connection methodPluggable screw connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.20
Conductor cross section AWG max.12
Stripping length7 mm
Screw threadM3

Connection data, output

Connection methodPluggable screw connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.20
Conductor cross section AWG max.12
Stripping length7 mm
Screw threadM3

Ambient conditions

Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Climatic class3K3 (in acc. with EN 60721)
Degree of pollution2
Installation height5000 m
Degree of protectionIP20
Ambient temperature (operation)-25 °C - 70 °C (> 60 °C Derating: 2.5 %/K)
Ambient temperature (storage/transport)-40 °C - 85 °C

Connection data for signaling

Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.20
Conductor cross section AWG max.12
Screw threadM3

Frequently bought together


Other PHOENIX CONTACT items

Request a quote