Relay Module - PLC-RSC- 24DC/21-21 - 2967060
- Manufactured by:
- PHOENIX CONTACT
PLC relay, consisting of base terminal block PLC-BSC.../21 with screw connection and pluggable miniature relay with power contact, for assembly on DIN rail NS 35/7.5, 2 PDT, input voltage 24 V DC
Features
Slim design
Efficient connection to system cabling using V8 adapter
RT III sealed relay
Safe isolation according to DIN EN 50178 between coil and contact
Integrated input circuit and interference suppression circuit
Functional plug-in bridges
cULus Listed
RC FRT
cULus Recognized
EAC
PRS
DNV GL
UL Listed
cUL Listed
UL Recognized
cUL Recognized
Specifications
Depth | 94 mm |
---|---|
Height | 80 mm |
Strip Length | 8 mm |
Width | 14 mm |
Environmental Product Compliance | |
REACh SVHC | Lead 7439-92-1 |
China RoHS | Environmentally Friendly Use Period = 50 years |
China RoHS | For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration' |
Dimensions | |
Width | 14 mm |
Height | 80 mm |
Depth | 94 mm |
Contact side | |
Contact type | 2 PDT |
Type of switch contact | Single contact |
Contact material | AgNi |
Maximum switching voltage | 250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...) |
Minimum switching voltage | 5 V AC/DC (at 10 mA) |
Min. switching current | 10 mA (At 5 V) |
Maximum inrush current | 15 A (300 ms) |
Limiting continuous current | 6 A |
Interrupting rating (ohmic load) max. | 140 W (at 24 V DC) |
Interrupting rating (ohmic load) max. | 85 W (at 48 V DC) |
Interrupting rating (ohmic load) max. | 60 W (at 60 V DC) |
Interrupting rating (ohmic load) max. | 44 W (at 110 V DC) |
Interrupting rating (ohmic load) max. | 60 W (at 220 V DC) |
Interrupting rating (ohmic load) max. | 1500 VA (for 250 V AC) |
Switching capacity | 2 A (at 24 V, DC13) |
Switching capacity | 3 A (at 24 V, AC15) |
Switching capacity | 3 A (at 120 V, AC15) |
Switching capacity | 0.2 A (at 250 V, DC13) |
Switching capacity | 3 A (at 250 V, AC15) |
Connection data | |
Connection name | Coil side |
Connection method | Screw connection |
Stripping length | 8 mm |
Screw thread | M3 |
Conductor cross section solid | 0.14 mm² - 2.5 mm² |
Conductor cross section flexible | 0.14 mm² - 2.5 mm² |
Conductor cross section flexible | 0.2 mm² - 2.5 mm² (Single ferrule) |
Conductor cross section flexible | 2x 0.5 mm² - 1.5 mm² (TWIN ferrule) |
Conductor cross section AWG | 26 - 14 |
Connection data 2 | |
Connection name | Contact side |
Connection method | Screw connection |
Stripping length | 8 mm |
Screw thread | M3 |
Conductor cross section solid | 0.14 mm² - 2.5 mm² |
Conductor cross section flexible | 0.14 mm² - 2.5 mm² |
Conductor cross section flexible | 0.2 mm² - 2.5 mm² (Single ferrule) |
Conductor cross section flexible | 2x 0.5 mm² - 1.5 mm² (TWIN ferrule) |
Conductor cross section AWG | 26 - 14 |
Coil side | |
Typical input current at UN | 18 mA |
Typical response time | 8 ms |
Typical release time | 10 ms |
Protective circuit | Reverse polarity protection Polarity protection diode |
Protective circuit | Free-wheeling diode Damping diode |
Operating voltage display | Yellow LED |
Power dissipation for nominal condition | 0.43 W |
Nominal input voltage UN | 24 V DC |
Standards and Regulations | |
Connection in acc. with standard | CUL |
Designation | Standards/regulations |
Standards/regulations | IEC 60664 |
Standards/regulations | EN 50178 |
Rated surge voltage | 6 kV |
Insulation | Safe isolation: Control side / contact side |
Pollution degree | 2 |
Overvoltage category | III |
Ambient conditions | |
Ambient temperature (operation) | -40 °C - 60 °C |
Ambient temperature (storage/transport) | -40 °C - 85 °C |
Degree of protection | RT III (Relay) |
Degree of protection | IP20 (Relay base) |
Note | |
Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |