Relay Module - PLC-RSC- 24DC/ 1- 1/ACT - 2967109

Manufactured by:
PHOENIX CONTACT
Phoenix%20contact

463c09cc67eb65896f571acf8f1f8ad09118ee3e medium
Price (VAT excluded)
€ 19.16
Nuova Elva code
2967109
Manufacturer code
2967109
Availability
Send request for quotation

PLC-INTERFACE for output functions, consisting of PLC-BSC.../ACT basic terminal block with screw connection and plug-in miniature relay with power contact, for mounting on DIN rail NS 35/7,5, 2 N/O contacts (1-1), input voltage 24 V DC

Features

  • Actuator connected directly to relay module

  • Efficient connection to system cabling using V8 adapter

  • No need for additional modular terminal blocks

  • Time savings of up to 60 %

  • Relay modules with safe isolation according to DIN EN 50178 between coil and contact

  • Space savings of up to 80 %

  • Functional plug-in bridges

  • cULus Listed

  • cULus Recognized

  • EAC

  • PRS

  • DNV GL

  • UL Listed

  • cUL Listed

  • UL Recognized

  • cUL Recognized

Specifications

Depth94 mm
Height80 mm
Strip Length8 mm
Width14 mm

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 50 years
China RoHSFor details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration'

Dimensions

Width14 mm
Height80 mm
Depth94 mm

Contact side

Contact type2 N/O contacts
Type of switch contactSingle contact
Contact materialAgNi
Maximum switching voltage250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...)
Minimum switching voltage5 V AC/DC
Min. switching current10 mA
Maximum inrush current8 A
Limiting continuous current6 A
Interrupting rating (ohmic load) max.140 W (at 24 V DC)
Interrupting rating (ohmic load) max.85 W (at 48 V DC)
Interrupting rating (ohmic load) max.60 W (at 60 V DC)
Interrupting rating (ohmic load) max.40 W (at 110 V DC)
Interrupting rating (ohmic load) max.60 W (at 220 V DC)
Interrupting rating (ohmic load) max.1500 VA (for 250 V AC)
Switching capacity2 A (at 24 V, DC13)
Switching capacity0.2 A (at 250 V, DC13)
Switching capacity3 A (at 24 V, AC15)
Switching capacity3 A (at 120 V, AC15)
Switching capacity3 A (at 250 V, AC15)

Connection data

Connection nameCoil side
Connection methodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section solid0.14 mm² - 2.5 mm²
Conductor cross section flexible0.14 mm² - 2.5 mm²
Conductor cross section flexible0.2 mm² - 2.5 mm² (Single ferrule)
Conductor cross section flexible2x 0.5 mm² - 1.5 mm² (TWIN ferrule)
Conductor cross section AWG26 - 14

Connection data 2

Connection nameContact side
Connection methodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section solid0.14 mm² - 2.5 mm²
Conductor cross section flexible0.14 mm² - 2.5 mm²
Conductor cross section flexible0.2 mm² - 2.5 mm² (Single ferrule)
Conductor cross section flexible2x 0.5 mm² - 1.5 mm² (TWIN ferrule)
Conductor cross section AWG26 - 14

Coil side

Typical input current at UN18 mA
Typical response time8 ms
Typical release time10 ms
Protective circuitReverse polarity protection Polarity protection diode
Protective circuitFree-wheeling diode Damping diode
Operating voltage displayYellow LED
Power dissipation for nominal condition0.43 W
Nominal input voltage UN24 V DC

Standards and Regulations

Connection in acc. with standardCUL
DesignationStandards/regulations
Standards/regulationsIEC 60664
Standards/regulationsEN 50178
InsulationBasic insulation
Pollution degree3
Overvoltage categoryIII

Ambient conditions

Ambient temperature (operation)-40 °C - 60 °C
Ambient temperature (storage/transport)-40 °C - 85 °C
Degree of protectionRT III (Relay)
Degree of protectionIP20 (Relay base)

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Frequently bought together


Other PHOENIX CONTACT items

Request a quote