RSS 36-I2-D-ST

Manufactured by:
SCHMERSAL
Schmersal

C0e7b083b743bea2d6b7814c425a867884e0101e medium
Nuova Elva code
101216956
Availability
Send request for quotation

Features

  • Repeated individual coding with RFID technology

  • Coding level "High" according to ISO 14119

  • 1 x connector socket M12, 8-pole

  • Actuation from side

  • Thermoplastic enclosure

  • RFID-technology for needs-based protection against tampering

  • Misaligned actuation possible

  • 27 mm x 108.2 mm x 35 mm

  • High repeat accuracy of the switching points

  • 2 short-circuit proof PNP safety outputs

  • Integral cross-short, wire-breakage and external voltage monitoring of the safety cables up to the control cabinet

  • Teaching of the individual coding of a RST actuator through a simple routine during start-up (as -I1). A protected coding process enables teaching a new actuator in case of maintenance.

Specifications

Ambient Temperature-25 °C
CertificationsCULus
Enclosure MaterialGlass-fibre Reinforced Thermoplastic
StandardEN 62061
Weight80 g

Approval - Standards

CertificatesTÜV | cULus | ECOLAB | EAC | FCC | IC

General data

StandardsIEC 60947-5-3
general informationIndividual coding, multiple teaching
Time to readiness, maximum2,000 ms
Reaction time, maximum100 ms
Duration of risk, maximum200 ms
Coding level according to ISO 14119High
Active principleRFID
Housing construction formBlock
Installation conditions (mechanical)not flush
Sensor topologySensor for series wiring
Enclosure materialPlastic, glass-fibre reinforced thermoplastic, self-extinguishing
Active areaGlass-fibre, reinforced thermoplastic
Gross weight80 g

General data - Features

Diagnostic outputYes
Short circuit detectionYes
Short-circuit recognitionYes
Safety functionsYes
CascadableYes
Integral System Diagnostics, statusYes
Number of LEDs3
Number of semi-conductor outputs with signaling function1
Number of fail-safe digital outputs2

Safety appraisal

StandardsEN ISO 13849-1 | IEC 60947-5-3 | EN 62061 | IEC 61508
Performance level, up toe
Control category to EN138494
PFH-value2.70 x 10⁻¹⁰ /h
Safety Integrity Level (SIL), suitable for applications in3
Mission Time20 Year(s)

Mechanical data

Actuating panelslateral
Active arealateral
Hysteresis (Switch distance), maximum2 mm
Repeat accuracy R R0.5 mm
Note (Repeat accuracyAxial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 8 mm (e.g. mounting tolerance or due to guard door sagging). The axial misalignment (y) is max. ± 18 mm (see figure: Operating principle). Minimum clearance between two sensor systems 100 mm.
MountingA screw length of 25 mm is sufficient for sensor mounting and for side mounting of the actuators. 30 mm long screws are recommended when the actuator is mounted upright and/or when the sealing discs are used.

Mechanical data - Switching distances according IEC 60947-5-3

Switch distance12 mm
Ensured switch distance "ON" S10 mm
Ensured switch distance "OFF" S20 mm

Mechanical data - Connection technique

Terminal ConnectorConnector M12, 8-pole
NoteThe cable section of the interconnecting cable must be observed! Cable length and cable section alter the voltage drop depending on the output current

Mechanical data - Dimensions

Length of sensor22 mm
Width of sensor106.3 mm
Height of sensor25 mm

Ambient conditions

Degree of protectionIP65 to EN 60529 | IP67 to EN 60529 | IP69 to EN 60529
Ambient temperature, minimum-25 °C
Protection ratingIII
Ambient temperature, maximum+70 °C
Storage and transport temperature, minimum-25 °C
Storage and transport temperature, maximum+85 °C
Material temperature resistance of the cable (in motion), minimum-10 °C
Material temperature resistance of the cable (at rest), minimum-30 °C
Material temperature resistance (long-term), maximum+105 °C
Resistance to vibrations to EN 60068-2-610 … 55 Hz, amplitude 1 mm
Restistance to shock30 g / 11 ms

Ambient conditions - Insulation value

Rated insulation voltage U32 VDC
Rated impulse withstand voltage U0.8 kV
Overvoltage categoryIII
Degree of pollution to VDE 01003

Electrical data

Voltage typeDC (direct current)
No-load supply current I100 mA
Rated operating voltage24 VDC −15 % / +10 %
Rated operating voltage, minimum20.4 VDC
Rated operating voltage, maximum26.4 VDC
Operating current600 mA
Required rated short-circuit current to EN 60947-5-1100 A
Switching frequency, approx.1 Hz

Electrical data - Fail-safe digital outputs

Rated operating current (safety outputs)250 mA
Output current, (fail-safe output), maximum0.25 A
Versionsp-type
Voltage drop U1 V
Current leakage I0.5 mA
Voltage, Utilisation category DC-1224 VDC
Current, Utilisation category DC-120.25 A
Voltage, Utilisation category DC-1324 VDC
Current, Utilisation category DC-130.25 A

Electrical data - Diagnostic output

Versionsp-type
Voltage drop U2 V
Voltage, Utilisation category DC-1224 VDC
Current, Utilisation category DC-120.05 A
Voltage, Utilisation category DC-1324 VDC
Current, Utilisation category DC-130.05 A

Electrical data - Electromagnetic compatibility (EMC)

Interfering radiationIEC 61000-6-4
EMC ratingIEC 60947-3

Status indication

Note (LED switching conditions display)LED yellow: Operating condition | LED green: Supply voltage | LED red: Fault

Pin assignment

PIN 1A1 Ue Brown
PIN 2X1 Safety input 1 White
PIN 3A2 GND Blue
PIN 4Y1 Safety output 1 Black
PIN 5OUT Diagnostic output OUT Grey
PIN 6X2 Safety input 2 violet
PIN 7Y2 Safety output 2 red
PIN 8IN without function Pink

Scope of delivery

Included in deliveryActuators must be ordered separately.

Accessory

Recommendation (actuator)RST 36-1 | RST 36-1-R
Recommended safety switchgearPROTECT PSC1 | SRB-E-301ST | SRB-E-201LC

Docs


Frequently bought together


Other SCHMERSAL items

Request a quote