AZM400Z-ST-I2-1P2P-T
- Manufactured by:
- SCHMERSAL
- Price (VAT excluded)
- € 579.49
- Nuova Elva code
- 103003841
- Manufacturer code
- 103003841
- Availability
- Send request for quotation
Features
Repeated individual coding with RFID technology
Coding level "High" according to ISO 14119
Connector M12, 8-pole
Guard locking monitored
1 Diagnostic output
Emergency exit
Bistable, motor-driven system
Clamping force 10.000
Release possible against lateral forces up to 300 N
PL e / cat. 4 / SIL 3 for interlocking and guard locking function
Two-channel input signal of the guard locking function
Operation on P/P- and P/N-switching outputs
High tolerance to door misalignment
Specifications
Ambient Temperature | -20 °C |
---|---|
Certifications | CULus |
Enclosure Material | Light Alloy Die-casting |
Standard | EN ISO 13849-1 |
Weight | 846 g |
Approval - Standards | |
Certificates | TÜV | cULus | EAC | FCC | IC |
General data | |
Standards | IEC 60947-5-1 | EN ISO 13849-1 | IEC 61508 | EN ISO 14119 |
general information | Individual coding, multiple teaching |
Coding level according to ISO 14119 | High |
Active principle | Magnetic field | RFID |
Enclosure material | Light alloy die-casting |
Gross weight | 846 g |
Time to readiness, maximum | 1,500 ms |
Reaction time, maximum | 100 ms |
General data - Features | |
Guard locking monitored | Yes |
Emergency exit | Yes |
Short circuit detection | Yes |
Short-circuit recognition | Yes |
Safety functions | Yes |
Integral System Diagnostics, status | Yes |
Number of diagnostic signals | 1 |
Number of safety contacts | 2 |
Safety appraisal | |
Standards | IEC 61508 | EN ISO 13849-1 |
Safety appraisal - Interlocking | |
Performance level, up to | e |
Control category | 4 |
PFH-value | 1.00 x 10⁻⁹ /h |
PFD value | 9.00 x 10⁻⁵ |
Safety Integrity Level (SIL), suitable for applications in | 3 |
Mission Time | 20 Year(s) |
Safety appraisal - Guard locking | |
Performance level, up to | e |
Control category | 4 |
PFH-value | 1.80 x 10⁻⁹ /h |
PFD value | 1.60 x 10⁻⁴ |
Safety Integrity Level (SIL), suitable for applications in | 3 |
Mission Time | 20 Year(s) |
Mechanical data | |
Interlocking principle | bistable |
Mechanical life, minimum | 1,000,000 Operations |
Note (Mechanical lifetime) | Which have a lateral force Ftrans = 100 N: 100.000 operations |
Minimum distance devices | 30 mm |
Clamping force in accordance with EN ISO 14119 F | 10,000 N |
Clamping force, maximum F | 13,000 N |
Lateral force at bolt return, maximal (against locked door) | 300 N |
Note (Lateral force at bolt return) | Does not apply to emergency exit, Bowden cable and manual release |
Tightening torque of the screw | 8 Nm |
Mechanical data - Connection technique | |
Terminal Connector | Connector M12, 8-pole |
Mechanical data - Dimensions | |
Length of sensor | 65.3 mm |
Width of sensor | 77.8 mm |
Height of sensor | 166.7 mm |
Ambient conditions | |
Degree of protection | IP66 to EN 60529 | IP67 to EN 60529 |
Ambient temperature, minimum | -20 °C |
Ambient temperature, maximum | +55 °C |
Storage and transport temperature, minimum | -40 °C |
Storage and transport temperature, maximum | +85 °C |
Resistance to vibrations to EN 60068-2-6 | 10 … 150 Hz, amplitude 0.35 mm |
Restistance to shock | 30 g / 11 ms |
Protection rating | III |
Ambient conditions - Insulation value | |
Rated insulation voltage U | 32 VDC |
Rated impulse withstand voltage U | 0.8 kV |
Overvoltage category | III |
Degree of pollution to VDE 0100 | 3 |
Electrical data | |
Operating Current | 100 mA |
Current consumption, maximum | 600 mA |
Open / close cycle (Motor), minimum | 3 |
Minimal average cycle time (with continuous operation) | 20 s |
Current consumption at 24V, minimum | 10 mA |
Current consumption at 24V, maximum | 15 mA |
No-load supply current I | 100 mA |
Rated operating voltage | 24 VDC |
Operating current | 50 mA |
Required rated short-circuit current to EN 60947-5-1 | 100 A |
Switching frequency, approx. | 0.3 Hz |
Electrical data - Control inputs | |
Switching thresholds of the control inputs | −3 V … 5 V (Low) | 15 V … 30 V (High) |
Allowable discrepancy time (input), maximum | 10 s |
Classification ZVEI CB24I, Sink | C0 |
Classification ZVEI CB24I, Source | C1 | C2 | C3 |
Electrical data - Fail-safe digital inputs | |
Classification ZVEI CB24I, Sink | C1 |
Electrical data - Fail-safe digital outputs | |
Rated operating current (safety outputs) | 250 mA |
Voltage drop U | 2 V |
Current leakage I | 1.5 mA |
Voltage, Utilisation category DC-12 | 24 VDC |
Current, Utilisation category DC-12 | 0.25 A |
Voltage, Utilisation category DC-13 | 24 VDC |
Current, Utilisation category DC-13 | 0.25 A |
Classification ZVEI CB24I, Source | C2 |
Classification ZVEI CB24I, Sink | C1 | C2 |
Electrical data - Diagnostic output | |
Versions | short-circuit proof, p-type |
Voltage drop U | 2 V |
Voltage, Utilisation category DC-12 | 24 VDC |
Current, Utilisation category DC-12 | 0.05 A |
Voltage, Utilisation category DC-13 | 24 VDC |
Current, Utilisation category DC-13 | 0.05 A |
Status indication | |
Note (LED switching conditions display) | Operating condition: LED green | Error / functional defect: LED red | Supply voltage UB: LED green |
Pin assignment | |
PIN 1 | A1 Supply voltage UB |
PIN 2 | X2 Safety input 2 |
PIN 3 | A2 GND |
PIN 4 | Y1 Safety output 1 |
PIN 5 | OUT Diagnostic output |
PIN 6 | E3 Control input 3 |
PIN 7 | Y2 Safety output 2 |
PIN 8 | E2 Control input 2 |
Scope of delivery | |
Included in delivery | Actuators must be ordered separately. |
Delivery scope of Mounting material | 2 x M6 (10.9) |
Accessory | |
Recommendation (actuator) | AZM400-B1 |