AES1337
- Manufactured by:
- SCHMERSAL
Features
Monitoring of BNS range magnetic safety sensors
3 safety contacts, STOP 0
1 Signalling output
Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.
Specifications
Ambient Temperature | -25 °C |
---|---|
Certifications | BG |
Depth | 121 mm |
Enclosure Material | Glass-fibre Reinforced Thermoplastic |
Height | 100 mm |
Standard | BG-GS-ET-14 |
Weight | 280 g |
Width | 22.5 mm |
Specifications | |
Width | 22.5 mm |
Height | 100 mm |
Depth | 121 mm |
Approval - Standards | |
Certificates | BG | cULus | CCC | EAC |
General data | |
Standards | IEC 61508 | IEC/EN 60204-1 | IEC 60947-5-3 | BG-GS-ET-14 | EN ISO 13849-1 |
Climatic stress | EN 60068-2-78 |
Enclosure material | Glass-fibre reinforced thermoplastic, ventilated |
Material of the contacts, electrical | AgSn0. self-cleaning, positive drive |
Gross weight | 280 g |
General data - Features | |
Stop-Category | 0 |
Electronic Fuse | Yes |
Number of auxiliary contacts | 1 |
Number of LEDs | 4 |
Number of openers | 1 |
Number of shutters | 1 |
Number of safety contacts | 3 |
Wire breakage detection | Yes |
Short-circuit recognition | Yes |
Start input | Yes |
Feedback circuit | Yes |
Automatic reset function | Yes |
Reset edge detection | Yes |
Earth connection detection | Yes |
Integral System Diagnostics, status | Yes |
Safety appraisal | |
Standards | EN 60947-5-1 | IEC 61508 |
Safety appraisal - Relay outputs | |
Performance Level, up to | e |
Control category to EN13849 | 4 |
Diagnostic Coverage (DC) Level | ≥ 99 % |
PFH-value | 2.00 x 10⁻⁸ /h |
Safety Integrity Level (SIL), suitable for applications in | 3 |
Mission time | 20 Year(s) |
Common Cause Failure (CCF), minimum | 65 |
Mechanical data | |
Mechanical life, minimum | 10,000,000 Operations |
Mounting | Snaps onto standard DIN rail to EN 60715 |
Mechanical data - Connection technique | |
Terminal Connector | rigid or flexible | Screw terminals M20 x 1.5 |
Terminal designations | IEC/EN 60947-1 |
Cable section, minimum | 0.25 mm² |
Cable section, maximum | 2.5 mm² |
Tightening torque of Clips | 0.6 Nm |
Mechanical data - Dimensions | |
Width | 22.5 mm |
Height | 100 mm |
Depth | 121 mm |
Ambient conditions | |
Degree of protection of the enclosure | IP40 |
Degree of protection of the mounting space | IP54 |
Degree of protection of clips or terminals | IP20 |
Ambient temperature, minimum | -25 °C |
Ambient temperature, maximum | +45 °C |
Storage and transport temperature, minimum | -40 °C |
Storage and transport temperature, maximum | +85 °C |
Resistance to vibrations to EN 60068-2-6 | 10 ... 55 Hz, Amplitude 0.35 mm |
Restistance to shock | 10 g / 11 ms |
Ambient conditions - Insulation value | |
Overvoltage category | III |
Degree of pollution to VDE 0100 | 2 |
Electrical data | |
Frequency range | 50 Hz | 60 Hz |
Thermal test current | 6 A |
Contact resistance, maximum | 0.1 Ω |
Note (Contact resistance) | in new state |
Drop-out delay in case of power failure, typically | 80 ms |
Drop-out delay in case of emergency, typically | 20 ms |
Pull-in delay at automatic start, maximum, typically | 100 ms |
Pull-in delay at RESET, typically | 20 ms |
Rated AC voltage for controls, 50 Hz, minimum | 20.4 VAC |
Rated control voltage at AC 50 Hz, maximum | 26.4 VAC |
Rated AC voltage for controls, 60 Hz, minimum | 20.4 VAC |
Rated control voltage at AC 60 Hz, maximum | 26.4 VAC |
Rated AC voltage for controls at DC minimum | 20.4 VDC |
Rated control voltage at DC, maximum | 28.8 VDC |
Electrical power consumption | 2.1 W |
Electrical power consumption | 3.5 VA |
Electrical data - Safe relay outputs | |
Voltage, Utilisation category AC-15 | 230 VAC |
Current, Utilisation category AC-15 | 6 A |
Voltage, Utilisation category DC-13 | 24 VDC |
Current, Utilisation category DC-13 | 6 A |
Switching capacity, minimum | 10 VDC |
Switching capacity, minimum | 10 mA |
Switching capacity, maximum | 250 VAC |
Switching capacity, maximum | 8 A |
Electrical data - Digital inputs | |
Conduction resistance, maximum | 40 Ω |
Electrical data - Relay outputs (auxiliary contacts) | |
Switching capacity, maximum | 24 VDC |
Switching capacity, maximum | 2 A |
Electrical data - Electromagnetic compatibility (EMC) | |
EMC rating | EMC-Directive |
Status indication | |
Indicated operating states | Position relay K2 | Position relay K1 | Internal operating voltage U |
Other data | |
Note (applications) | Safety sensor | Guard system |
Circuit example | |
Note (Wiring diagram) | The wiring diagram is shown with guard doors closed and in de-energised condition. | Monitoring 1 guard door(s), each with a magnetic safety sensor of the BNS range | The feedback circuit monitors the position of the contactors K3 and K4. | To secure a guard door up to PL e and Category 4 | Automatic start: The automatic start is programmed by connecting the feedback circuit to the terminals X1/X3. If the feedback circuit is not required, establish a bridge. | Start button (S) with edge detection |