AES1337

Manufactured by:
SCHMERSAL
Schmersal

60e24f1a28e4ca5d447ef0adc65a0c86f843eead medium
Nuova Elva code
1172210
Manufacturer code
101172210
Availability
Send request for quotation

Features

  • Monitoring of BNS range magnetic safety sensors

  • 3 safety contacts, STOP 0

  • 1 Signalling output

  • Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit.

Specifications

Ambient Temperature-25 °C
CertificationsBG
Depth121 mm
Enclosure MaterialGlass-fibre Reinforced Thermoplastic
Height100 mm
StandardBG-GS-ET-14
Weight280 g
Width22.5 mm

Specifications

Width22.5 mm
Height100 mm
Depth121 mm

Approval - Standards

CertificatesBG | cULus | CCC | EAC

General data

StandardsIEC 61508 | IEC/EN 60204-1 | IEC 60947-5-3 | BG-GS-ET-14 | EN ISO 13849-1
Climatic stressEN 60068-2-78
Enclosure materialGlass-fibre reinforced thermoplastic, ventilated
Material of the contacts, electricalAgSn0. self-cleaning, positive drive
Gross weight280 g

General data - Features

Stop-Category0
Electronic FuseYes
Number of auxiliary contacts1
Number of LEDs4
Number of openers1
Number of shutters1
Number of safety contacts3
Wire breakage detectionYes
Short-circuit recognitionYes
Start inputYes
Feedback circuitYes
Automatic reset functionYes
Reset edge detectionYes
Earth connection detectionYes
Integral System Diagnostics, statusYes

Safety appraisal

StandardsEN 60947-5-1 | IEC 61508

Safety appraisal - Relay outputs

Performance Level, up toe
Control category to EN138494
Diagnostic Coverage (DC) Level≥ 99 %
PFH-value2.00 x 10⁻⁸ /h
Safety Integrity Level (SIL), suitable for applications in3
Mission time20 Year(s)
Common Cause Failure (CCF), minimum65

Mechanical data

Mechanical life, minimum10,000,000 Operations
MountingSnaps onto standard DIN rail to EN 60715

Mechanical data - Connection technique

Terminal Connectorrigid or flexible | Screw terminals M20 x 1.5
Terminal designationsIEC/EN 60947-1
Cable section, minimum0.25 mm²
Cable section, maximum2.5 mm²
Tightening torque of Clips0.6 Nm

Mechanical data - Dimensions

Width22.5 mm
Height100 mm
Depth121 mm

Ambient conditions

Degree of protection of the enclosureIP40
Degree of protection of the mounting spaceIP54
Degree of protection of clips or terminalsIP20
Ambient temperature, minimum-25 °C
Ambient temperature, maximum+45 °C
Storage and transport temperature, minimum-40 °C
Storage and transport temperature, maximum+85 °C
Resistance to vibrations to EN 60068-2-610 ... 55 Hz, Amplitude 0.35 mm
Restistance to shock10 g / 11 ms

Ambient conditions - Insulation value

Overvoltage categoryIII
Degree of pollution to VDE 01002

Electrical data

Frequency range50 Hz | 60 Hz
Thermal test current6 A
Contact resistance, maximum0.1 Ω
Note (Contact resistance)in new state
Drop-out delay in case of power failure, typically80 ms
Drop-out delay in case of emergency, typically20 ms
Pull-in delay at automatic start, maximum, typically100 ms
Pull-in delay at RESET, typically20 ms
Rated AC voltage for controls, 50 Hz, minimum20.4 VAC
Rated control voltage at AC 50 Hz, maximum26.4 VAC
Rated AC voltage for controls, 60 Hz, minimum20.4 VAC
Rated control voltage at AC 60 Hz, maximum26.4 VAC
Rated AC voltage for controls at DC minimum20.4 VDC
Rated control voltage at DC, maximum28.8 VDC
Electrical power consumption2.1 W
Electrical power consumption3.5 VA

Electrical data - Safe relay outputs

Voltage, Utilisation category AC-15230 VAC
Current, Utilisation category AC-156 A
Voltage, Utilisation category DC-1324 VDC
Current, Utilisation category DC-136 A
Switching capacity, minimum10 VDC
Switching capacity, minimum10 mA
Switching capacity, maximum250 VAC
Switching capacity, maximum8 A

Electrical data - Digital inputs

Conduction resistance, maximum40 Ω

Electrical data - Relay outputs (auxiliary contacts)

Switching capacity, maximum24 VDC
Switching capacity, maximum2 A

Electrical data - Electromagnetic compatibility (EMC)

EMC ratingEMC-Directive

Status indication

Indicated operating statesPosition relay K2 | Position relay K1 | Internal operating voltage U

Other data

Note (applications)Safety sensor | Guard system

Circuit example

Note (Wiring diagram)The wiring diagram is shown with guard doors closed and in de-energised condition. | Monitoring 1 guard door(s), each with a magnetic safety sensor of the BNS range | The feedback circuit monitors the position of the contactors K3 and K4. | To secure a guard door up to PL e and Category 4 | Automatic start: The automatic start is programmed by connecting the feedback circuit to the terminals X1/X3. If the feedback circuit is not required, establish a bridge. | Start button (S) with edge detection

Docs


Frequently bought together


Other SCHMERSAL items

Request a quote