ET 200SP, DQ 8X24VDC/0,5A ST
- Manufactured by:
- SIEMENS
- Nuova Elva code
- 6ES71326BF000BA0
- Manufacturer code
- 6ES7132-6BF00-0BA0
- Availability
- Send request for quotation
Simatic ET 200SP, Digital Output Module, DQ 8X24VDC/0.5A Standard, Fits to BU-Type A0, Color Code CC02, Module Diagnosis
Specifications
Connection Type | Push-In Terminal |
---|---|
Depth | 58 mm |
Height | 73 mm |
IP Rating | IP20 |
Max. Voltage | 28.8 V |
Output Voltage | 24 V |
Voltage | 24 V |
Weight | .036 kg |
Width | 15 mm |
Specifications | |
Consumed current maximum Note | without load |
Width [mm] | 15 |
Wire length at digital output shielded maximum [m] | 1000 |
Wire length at digital output unshielded maximum [m] | 600 |
Delay time at signal change at digital output with resistive load for signal <0> to <1> maximum [µs] | 50 |
Delay time at signal change at digital output with resistive load for signal <0> to <1> maximum Note | at rated load |
Delay time at signal change at digital output with resistive load for signal <1> to <0> maximum [µs] | 100 |
Delay time at signal change at digital output with resistive load for signal <1> to <0> maximum Note | at rated load |
Depth [mm] | 58 |
Design of the digital output | Source output (PNP, current-sourcing) |
Diagnostics function | Yes |
Diagnostics function Cable break | Yes |
Diagnostics function Cable break Note | Module-wise |
Net Weight in Kg | 0.036 |
Diagnostics function Group fault | Yes |
Diagnostics function Monitoring of the mains voltage of the electronic | Yes |
Diagnostics function Short-circuit detection | Yes |
Diagnostics function Short-circuit detection Note | Module-wise |
Display version for diagnostic function: Status display expansion modules module diagnostics (traffic light green-red-yellow or DIAG red/green) | Yes |
Display version for diagnostic function: Status display expansion modules module diagnostics (traffic light green-red-yellow or DIAG red/green) Note | green/red DIAG LED |
Display version for diagnostic function: Status display transmission channel channel diagnostics LED | No |
Display version for diagnostic function: Status display transmission channel channel status LED | Yes |
Display version for diagnostic function: Status display transmission channel channel status LED Note | Green LED |
Display version for diagnostic function: Supply voltage monitoring Power LED | Yes |
Supplier | Siemens AG |
Display version for diagnostic function: Supply voltage monitoring Power LED Note | green PWR LED |
Equipment marking acc. to DIN EN 81346-2 | K |
Explosion protection category for dust | No |
Explosion protection category for gas | ATEX II 3 G Ex nA II T4 ... T5 |
Explosion protection marking for intrinsic safety of related equipment EEx ia | No |
Explosion protection marking for intrinsic safety of related equipment EEx ib | No |
Firmware version | V1.1 |
Galvanic isolation at the universal inputs between the channels | No |
Galvanic isolation at the universal inputs between the channels and backing bus | Yes |
GSD version/revision with PROFIBus required | GSD Revision 5 |
Order number | 6ES7132-6BF00-0BA0 |
GSD version/revision with PROFINET required | GSDML V2.3 |
Height [mm] | 73 |
Load resistance at digital output maximum [Ohm] | 12000 |
Load resistance at digital output minimum [Ohm] | 48 |
Mounting type front mounting | Yes |
Mounting type rack mounting | Yes |
Mounting type rail mounting | Yes |
Mounting type wall mounting | No |
Number of digital outputs | 8 |
Number of interfaces acc. to PROFINET | 0 |
address range memory per module maximum [byte] | 1 |
Number of interfaces acc. to RS 485 | 0 |
Operating mode as digital output | Yes |
Operating mode digital output with standby mode | No |
Operating mode oversampling | No |
Operating mode pulse width modulation | No |
Output current at digital output for signal <1> Rated value [mA] | 500 |
Output voltage at DC Rated value [V] | 24 |
Power loss [W] typical [mW] | 1000 |
product brandname | Simatic DP |
Product category | Digital module output |
address range memory per module maximum Note | =+ 1 byte for QI information |
Product extension required separate bus coupler for fieldbus connection | Yes |
Product family | ET 200SP |
Product feature of the firmware version can be updated | Yes |
Product function at digital output control of a digital input | Yes |
Product function at digital output parallel switching of outputs for increasing the power | No |
Product function at the digital outputs Short circuit protection | Yes |
Product function digital outputs parameterizable | Yes |
Product function I&M data | Yes |
Product function I&M data Note | I&M0 to I&M3 |
Product function MSO | No |
Alert function Diagnostics alarm | Yes |
Product function Replacement value entry point | Yes |
Product function Reverse polarity protection | Yes |
Product type designation | ET 200SP, DQ 8x 24 V DC/0.5 A ST, PU 1 |
Product type designation of the racks usable | BU type A0 |
Protection class IP | IP20 |
Protocol is supported PROFIBus protocol | No |
Protocol is supported PROFINET IO protocol | No |
Protocol is supported PROFIsafe protocol | No |
Residual current at digital output with signal <0> maximum [µA] | 100 |
Software version for PCS 7 application required | V8.1 SP1 |
Color coding of labeling plates for module-specific use usable | CC02 |
Software version with STEP 7 required | V5.5 SP3 / - |
Software version with STEP 7 in the TIA Portal required | V11 SP2 / V13 |
Suitability for use safety-related function | No |
Supply voltage at DC Rated value [V] | 24 |
Supply voltage at DC rated value maximum [V] | 28.8 |
Supply voltage at DC rated value minimum [V] | 19.2 |
Switching capacity active power at digital output with filament lamp load maximum [W] | 5 |
Switching capacity current at digital output with resistive load maximum [A] | 0.5 |
Switching frequency at digital output with filament lamp load maximum [Hz] | 10 |
Switching frequency at digital output with inductive load maximum [Hz] | 2 |
Consumed current maximum [mA] | 35 |
Switching frequency at digital output with resistive load maximum [Hz] | 100 |
Total current of digital outputs in horizontal mounting position up to 60 °C per module maximum [A] | 4 |
Total current of digital outputs in vertical mounting position up to 50 °C per module maximum [A] | 4 |
Total current of digital outputs per channel maximum [A] | 0.5 |
Total current of digital outputs per module maximum [A] | 4 |
Type of electrical connection | Push-in terminal |
Type of isolation test | 707 V DC (type test) |
Type of voltage at digital output | DC |
Type of voltage of the supply voltage | DC |
Voltage limitation method of inductive trip voltage | Typ. L+ (-50 V) |
Delivery Information | |
Export Control Regulations | AL : N / ECCN : EAR99H |
Standard lead time ex-works | 1 Day/Days |
Net Weight (lb) | 0.079 lb |
Product Dimensions (W x L x H) | Not available |
Packaging Dimension | 2.559 x 3.071 x 0.906 |
Package size unit of measure | in |
Quantity Unit | 1 Piece |
Packaging Quantity | 1 |
Additional Product Information | |
EAN | 4025515080800 |
UPC | 40892933055 |
Commodity Code | 85389091 |
LKZ_FDB/ CatalogID | ST76 |
Product Group | 4520 |
Country of origin | Germany |
RoHS Compliance | Since: 01/31/2012 |
Returnable | Yes |