Specifications
Depth | 130 mm |
---|---|
Height | 125 mm |
Voltage | 28.8 V |
Width | 40 mm |
Specifications | |
Ambient temperature during operation maximum [°C] | 60 |
Amount of data of the address area of the inputs total [byte] | 2048 |
Number of synchronous error OBs | 2 |
Number of synchronous error OBs Note | OB 121, 122 |
Number of time-delay interrupt OBs | 2 |
Number of time-delay interrupt OBs Note | OB 20, 21 |
Number of time-of-day interrupt OBs | 1 |
Number of time-of-day interrupt OBs Note | OB 10 |
Number of units per rack maximum | 8 |
Number of variables of the test/commissioning function: Control maximum | 14 |
Number of variables of the test/commissioning function: Force maximum | 10 |
Number of variables of the test/commissioning function: Status maximum | 30 |
Amount of data of the address area of the outputs at the 2nd interface as DP master maximum [byte] | 2048 |
Number of variables of the test/commissioning function: Status/Control maximum | 30 |
Power loss [W] typical [mW] | 4500 |
Processing time for 1000 bit operations [ms] | 0.05 |
Processing time for bit operation typical [ns] | 50 |
Processing time for fixed-point arithmetic typical [µs] | 0.12 |
Processing time for floating-point arithmetic typical [µs] | 0.45 |
Processing time for word operations typical [ns] | 90 |
product brand name | SIMATIC |
Product category | CPU |
Product component display | no |
Amount of data of the address area of the outputs total [byte] | 2048 |
Product component Hardware real-time clock | yes |
Product extension Main memory expansion | no |
Product family | S7-300 |
Product feature of the hardware real-time clock buffered and synchronizable | yes |
Product feature of the memory buffered | yes |
Product feature of the memory buffered Note | Guaranteed by MMC (maintenance-free) |
Product feature redundancy capability | yes |
Product feature retentive operating hours counter | yes |
Product feature retentive operating hours counter Note | Must be restarted at each restart |
Product function at the 1st interface DP master | no |
Amount of data of the FC subprograms maximum [kbyte] | 64 |
Product function at the 1st interface DP slave | no |
Product function at the 1st interface Galvanic isolation | no |
Product function at the 1st interface MPI | yes |
Product function at the 1st interface PROFIBUS DP master | no |
Product function at the 1st interface PROFIBUS DP slave | no |
Product function at the 1st interface PtP | no |
Product function at the 2nd interface DP master | yes |
Product function at the 2nd interface DP slave | yes |
Product function at the 2nd interface Galvanic isolation | yes |
Product function at the 2nd interface MPI | no |
Buffer time of the hardware real-time clock typical [h] | 1008 |
Product function at the 2nd interface PROFIBUS DP master | yes |
Product function at the 2nd interface PROFIBUS DP slave | yes |
Product function at the 2nd interface PtP | no |
Product function of S7 counters adjustable retentive memory requirement | yes |
Product function of the S7 timers adjustable retentive memory requirement | yes |
Product function of the test/commissioning function Single step | yes |
Product function time synchronization | yes |
Produkteigenschaft des Puffers ohne Batterie | yes |
Produkteigenschaft des Puffers ohne Batterie Anmerkung | Program and data |
programming language CFC | yes |
Buffer time of the hardware real-time clock typical Note | At 40 °C ambient temperature |
programming language GRAPH | yes |
programming language HiGraph | yes |
programming language SCL | yes |
programming language STEP 7 | yes |
programming language STEP 7 Note | V5.2 SP1 or higher with HW update |
programming language usable FUP | yes |
programming language usable KOP | yes |
programming language usable STL | yes |
Protocol is supported AS-interface protocol | no |
Protocol is supported MODBUS protocol | no |
Buffering time in the event of power failure [ms] | 5 |
Protocol is supported other protocols | yes |
Protocol is supported other protocols Note | MPI |
Protocol is supported PROFIBUS protocol | yes |
Protocol is supported PROFINET CBA protocol | no |
Protocol is supported PROFINET IO protocol | no |
Protocol is supported PROFIsafe protocol | no |
Protocol is supported TCP/IP | no |
Safety Integrity Level (SIL) acc. to IEC 61508 | No |
Service at the 1st interface as MPI Global data communication | yes |
Service at the 1st interface as MPI PG/OP communication | yes |
communication function Dataset gateway | yes |
Service at the 1st interface as MPI Routing | yes |
Service at the 1st interface as MPI S7 basic communication | yes |
Service at the 1st interface as MPI S7 client communication | no |
Service at the 1st interface as MPI S7 communication | yes |
Service at the 1st interface as MPI S7 communication Note | Only server, configured on one side |
Service at the 1st interface as MPI S7 server communication | yes |
Service at the 2nd interface as DP master Activate/Deactivate DP-slaves | yes |
Service at the 2nd interface as DP master DPV1 | yes |
Service at the 2nd interface as DP master Equidistance support | yes |
Service at the 2nd interface as DP master Global data communication | no |
communication function S7 client communication | yes |
Service at the 2nd interface as DP master isochronous mode | yes |
Service at the 2nd interface as DP master isochronous mode Note | OB 61 |
Service at the 2nd interface as DP master PG/OP communication | yes |
Service at the 2nd interface as DP master Routing | yes |
Service at the 2nd interface as DP master S7 basic communication | yes |
Service at the 2nd interface as DP master S7 basic communication Note | I blocks only |
Service at the 2nd interface as DP master S7 client communication | no |
Service at the 2nd interface as DP master S7 communication | yes |
Service at the 2nd interface as DP master S7 communication Note | Only server, configured on one side |
Service at the 2nd interface as DP master S7 server communication | yes |
communication function S7 client communication Note | Via CP and loadable FB |
Service at the 2nd interface as DP master SYNC/FREEZE | yes |
Service at the 2nd interface as DP slave direct data exchange (DxB) | yes |
Service at the 2nd interface as DP slave DPV1 | no |
Service at the 2nd interface as DP slave Global data communication | no |
Service at the 2nd interface as DP slave PG/OP communication | yes |
Service at the 2nd interface as DP slave Routing | yes |
Service at the 2nd interface as DP slave Routing Note | Only with active interface |
Service at the 2nd interface as DP slave S7 basic communication | no |
Service at the 2nd interface as DP slave S7 client communication | no |
Service at the 2nd interface as DP slave S7 communication | yes |
Ambient temperature during operation minimum [°C] | 0 |
communication function S7 communication | yes |
Service at the 2nd interface as DP slave S7 communication Note | Only server, configured on one side |
Service at the 2nd interface as DP slave S7 server communication | yes |
Service at the 2nd interface as PROFIBUS DP master isochronous bus cycle | yes |
Storage capacity of the input transfer memory at the 2nd interface as DP slave [byte] | 244 |
Storage capacity of the output transfer memory at the 2nd interface as DP slave [byte] | 244 |
Storage capacity of the RAM Integrated [Kibyte] | 250 |
Suitability for use safety-related function | no |
Supply voltage at AC at 50 Hz rated value maximum Note | Not applicable |
Supply voltage at AC at 50 Hz rated value minimum Note | Not applicable |
Supply voltage at AC at 60 Hz rated value maximum Note | Not applicable |
communication function S7 server communication | yes |
Supply voltage at AC at 60 Hz rated value minimum Note | Not applicable |
Supply voltage at DC Rated value 24 V | yes |
Supply voltage at DC rated value maximum [V] | 28.8 |
Supply voltage at DC rated value minimum [V] | 19.2 |
Test-/initiation function adjustable Diagnostics buffer | no |
Test-/initiation function Component status | yes |
Test-/initiation function Component status Note | Up to 2 simultaneously |
Test-/initiation function Force | yes |
Test-/initiation function Integrated Diagnostics buffer | yes |
Test-/initiation function Status/Control variable | yes |
Consumed current during no-load operation typical [A] | 0.15 |
Transfer rate at the 1st interface as MPI maximum [kbit/s] | 187.5 |
Transfer rate at the 2nd interface as DP master maximum [Mbit/s] | 12 |
Transfer rate at the 2nd interface as DP slave maximum [bit/s] | 1.20E+07 |
Type of memory | other |
Type of voltage of the supply voltage | 24 V DC |
Width [mm] | 40 |
Consumed current rated value [mA] | 850 |
Depth [mm] | 130 |
Design of the external protection for mains supply line recommended | 2 A min. |
Design of the interface at the 1st interface | Integrated RS 485 interface |
Design of the interface at the 2nd interface | Integrated RS 485 interface |
Design of the PLC basic equipment | Modular |
Amount of data at the 2nd interface as DP master as reference data for outputs per distributed I/O slave maximum [byte] | 244 |
Equipment marking acc. to DIN EN 81346-2 | K |
Firmware version | V3.3 |
Height [mm] | 125 |
I2t value [A2.s] | 1 |
Inrush current typical [A] | 3.5 |
Mounting type front mounting | no |
Mounting type rack mounting | no |
Mounting type rail mounting | yes |
Mounting type wall mounting | no |
Number of address ranges at the 2nd interface as DP slave maximum | 32 |
Amount of data at the 2nd interface as DP master as user data for inputs per distributed I/O slave maximum [byte] | 244 |
Number of analog inputs | 0 |
Number of analog inputs addressable | 1024 |
Number of analog inputs centrally addressable | 256 |
Number of analog inputs/outputs addressable maximum | 1024 |
Number of analog inputs/outputs addressable maximum Note | Inputs and outputs in each case |
Number of analog outputs | 0 |
Number of analog outputs addressable | 1024 |
Number of analog outputs centrally addressable | 256 |
Number of asynchronous error OBs | 5 |
Number of asynchronous error OBs Note | OB 80, 82, 85, 86, 87 |
Amount of data at the 2nd interface as DP slave as user data per address range maximum [byte] | 32 |
Number of breakpoints of the test/commissioning function | 4 |
Number of CP LAN units recommended | 10 |
Number of cyclic interrupt OBs | 4 |
Number of cyclic interrupt OBs Note | OB 32, 33, 34, 35 |
Number of data blocks maximum | 1024 |
Number of data blocks maximum Note | Number range: 1 to 16000 |
Number of digital inputs | 0 |
Number of digital inputs addressable | 16384 |
Number of digital inputs centrally addressable | 1024 |
Number of digital inputs/outputs addressable maximum | 16384 |
Amount of data of data modules maximum [kbyte] | 64 |
Number of digital inputs/outputs addressable maximum Note | Inputs and outputs in each case |
Number of digital outputs | 0 |
Number of digital outputs addressable | 16384 |
Number of digital outputs centrally addressable | 1024 |
Number of DP masters Integrated | 1 |
Number of DP slaves at the 2nd interface as DP master can be activated/deactivated simultaneously maximum | 8 |
Number of DP slaves at the 2nd interface as DP master maximum | 124 |
Number of DP slaves at the 2nd interface as DP master maximum Note | Per station |
Number of DPV1 interrupt OBs | 3 |
Number of DPV1 interrupt OBs Note | OB 55, 56, 57 |
Amount of data of function blocks maximum [kbyte] | 64 |
Number of entries in the diagnostic buffer maximum | 500 |
Number of expansion devices maximum | 3 |
Number of FC subprograms maximum | 1024 |
Number of FC subprograms maximum Note | Number range: 0 to 7999 |
Number of free cycle OBs | 1 |
Number of free cycle OBs Note | OB 1 |
Number of function blocks maximum | 1024 |
Number of function blocks maximum Note | Number range: 0 to 7999 |
Number of function modules recommended | 8 |
Number of hardware interrupt OBs | 1 |
Amount of data of organization blocks maximum [kbyte] | 64 |
Number of hardware interrupt OBs Note | OB 40 |
Number of IEC counters Note | Unlimited (limited only by RAM capacity) |
Number of IEC timers Note | Unlimited (limited only by RAM capacity) |
Number of interfaces acc. to Industrial Ethernet | 0 |
Number of interfaces acc. to PROFINET | 0 |
Number of interfaces acc. to RS 422 | 0 |
Number of interfaces acc. to RS 485 | 2 |
Number of interfaces acc. to RS 485 Note | MPI and PROFIBUS DP |
Number of interfaces other | 0 |
Number of isochronous mode OBs | 1 |
Amount of data of the address area of the inputs at the 2nd interface as DP master maximum [byte] | 2048 |
Number of isochronous mode OBs Note | OB 61 |
Number of operating hours counters | 1 |
Number of point-to-point components recommended | 8 |
Number of possible connections for S7 basic communication usable | 12 |
Number of racks maximum | 4 |
Number of relay outputs Integrated maximum | 0 |
Number of S7 counters | 256 |
Number of S7 timers | 256 |
Number of startup OBs | 1 |
Number of startup OBs Note | OB 100 |
Delivery Information | |
Export Control Regulations | AL : N / ECCN : N |
Delivery Time | 1 Day/Days |
Net Weight (lb) | 0,732 lb |
Product Dimensions (W x L x H) | Not available |
Packaging Dimension | 5,157 x 5,748 x 2,008 |
Package size unit of measure | in |
Quantity Unit | 1 Piece |
Packaging Quantity | 1 |
Additional Product Information | |
EAN | 4025515077763 |
UPC | 40892550306 |
Commodity Code | 85371091 |
LKZ_FDB/ CatalogID | ST73 |
Product Group | 4030 |
Country of origin | Germany |
RoHS Compliance | Since: 11/25/2009 |
Returnable | Yes |
Obligation Category for taking back electrical and electronic equipment after use | No obligation to take back electrical and electronic equipment after use |