SINAMICS PM240-2 IP20-FSA-A-400V-3KW

Manufactured by:
SIEMENS
Siemens

8b5c4163456dcf518c3dbc3585e88761aecbebee medium
Price (VAT excluded)
€ 972.00
Nuova Elva code
6SL32101PE180AL1
Manufacturer code
6SL3210-1PE18-0AL1
Availability
Send request for quotation

SINAMICS POWER MODULE PM240-2 WITH BUILT IN CL. A FILTER WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 2,2KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 3KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP -10 TO +40 DEG C 196 X 73 X 165 (HXWXD), FSA PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU FIRMWARE- VERSION V4.6

Specifications

CertificationsC-Tick
Depth165 mm
Height196 mm
Weight1.5 kg
Width73 mm

Specifications

1 m measuring surface sound pressure level maximum [dB]71.6
Ambient temperature with low overload during operation minimum [°C]-5
Relative negative tolerance for line voltage [%]-10
Relative negative tolerance of line frequency [%]5
Relative positive tolerance for line voltage [%]10
Relative positive tolerance of line frequency [%]5
Relative power loss [W] of the CDM at the CDM operating point (0/100) [%]1.6
Relative power loss [W] of the CDM at the CDM operating point (0/25) [%]1.06
Relative power loss [W] of the CDM at the CDM operating point (0/50) [%]1.21
Relative power loss [W] of the CDM at the CDM operating point (50/100) [%]1.82
Relative power loss [W] of the CDM at the CDM operating point (50/25) [%]1.1
Relative power loss [W] of the CDM at the CDM operating point (50/50) [%]1.3
Ambient temperature [°F] during storage maximum [°F]131
Relative power loss [W] of the CDM at the CDM operating point (90/100) [%]2.17
Relative power loss [W] of the CDM at the CDM operating point (90/50) [%]1.43
Resistance to biologically active substances during operationClass 3B1 according to EN 60721-3-3
Resistance to biologically active substances during storageClass 1B1 according to EN 60721-3-1
Resistance to biologically active substances during transportClass 2B1 to EN 60721‑3‑2
Resistance to chemically active substances during operationClass 3C2 according to EN 60721-3-3
Resistance to chemically active substances during storageClass 1C2 according to EN 60721-3-1
Resistance to chemically active substances during transportClass 2C2 according to EN 60721-3-3
Shock acceleration during operation acc. to EN 60068-2-27 [m/s2]147
Shock acceleration during operation Note(15 × g)/11 ms
Ambient temperature [°F] during storage maximum NoteClass 1K3 acc. to EN 60721-3-1
Shock acceleration during transport acc. to EN 60721-3-2 NoteClass 2M3
Short-time withstand current (SCCR) of the entire control cabinet acc. to UL 508A [kA]65
Standard for EMC acc. to EN 61800-3The EMC product standard EN 61800-3 does not apply directly to a frequency inverter but to a PDS (Power Drive System), which comprises the complete circuitry, motor and cables in addition to the inverter.
Supplied active power at rated value of output voltage with high overload [kW]2.2
Supplied active power at rated value of output voltage with low overload [kW]3
Supplied active power [hp] at rated value of output voltage with high overload [hp]3
Supplied active power [hp] at rated value of output voltage with low overload [hp]4
Supply requirements for short circuit voltageu K < 1 % line reactor recommended
Supply voltage maximum [V]480
Supply voltage minimum [V]380
Ambient temperature [°F] during storage minimum [°F]-13
Touch protection acc. to EN 61800-5-1Assuming use as prescribed
Type of converterU converter
Type of coolingInternal air cooling
Type of cooling NotePower units with intensified air cooling thanks to integrated fan
Type of duty cycle duration with high overload1.5 × output current rating (i.e., 150 % overload) for 57 s with a cycle time of 300 s 2 × output current rating (i.e., 200 % overload) for 3 s with a cycle time of 300 s
Type of duty cycle duration with low overload1.1 x rated output current (i.e. 110 % overload) for 57 s with a cycle time of 300 s 1.5 × rated output current (i.e. 150 % overload) for 3 s with a cycle time of 300 s
Type of electrical connection for mains supply linePlug-in screw terminals
Type of electrical connection for PE conductorPlug-in screw terminals
Type of electrical connection of the motorPlug-in screw terminals
Type of voltage of the input voltageAC
Ambient temperature [°F] during transport maximum [°F]158
Type of voltage of the output voltageAC
Vibration frequency during transport acc. to EN 60721-3-2 NoteClass 2M3
Vibration frequency with constant acceleration during operation acc. to EN 60068-2-6 maximum [Hz]200
Vibration frequency with constant acceleration during operation acc. to EN 60068-2-6 maximum Noteconstant acceleration = 9.81 m/s2 (1 × g)
Vibration frequency with constant acceleration during operation acc. to EN 60068-2-6 minimum [Hz]58
Vibration frequency with constant deflection during operation acc. to EN 60068-2-6 maximum [Hz]58
Vibration frequency with constant deflection during operation acc. to EN 60068-2-6 maximum Noteconstant deflection 0.075 mm
Vibration frequency with constant deflection during operation acc. to EN 60068-2-6 minimum [Hz]10
Width [mm]73
Wire length for motor shielded maximum [m]50
Ambient temperature [°F] during transport maximum NoteClass 2K4 according to EN 60721-3-2
Wire length for motor unshielded maximum [m]100
Ambient temperature [°F] during transport minimum [°F]-40
Ambient temperature [°F] with high overload during operation maximum [°F]122
Ambient temperature [°F] with high overload during operation minimum [°F]23
Ambient temperature [°F] with low overload during operation maximum [°F]104
Ambient temperature during operation acc. to EN 60721-3-3 NoteClass 3K3, condensation, splashwater, and ice formation not permitted (EN 60204, Part 1)
Ambient temperature [°F] with low overload during operation minimum [°F]23
Apparent power output rated value [kVA]5.3
AWG number as coded connectable conductor cross section for mains supply line maximum14
AWG number as coded connectable conductor cross section for mains supply line minimum16
AWG number as coded connectable conductor cross section for motor supply line maximum14
AWG number as coded connectable conductor cross section for motor supply line minimum16
Brake versionDC braking, compound braking, resistance braking with integrated brake chopper (for size FSGX optional)
Certificate of suitabilityUL, cUL, CE, C-Tick (RCM), SEMI F47
Certificate of suitability for CE markingLow-voltage directive 2006/95/EC
Connectable conductor cross-section for mains supply line maximum [mm2]2.5
Ambient temperature during storage maximum [°C]55
Connectable conductor cross-section for mains supply line minimum [mm2]1.5
Connectable conductor cross-section for motor supply line maximum [mm2]2.5
Connectable conductor cross-section for motor supply line minimum [mm2]1.5
Consumed current from supply voltage for Control Unit at DC at 24 V [A]1
Cooling air flow [m3/s]0.005
Degree of pollution2 according to EN 61800-5-1
Depth [mm]165
Design of the converterFSA
Design of the net filterClass A
Displacement factor cos phi 10.95
Ambient temperature during storage minimum [°C]-25
Efficiency0.96
Electrical input frequency maximum [Hz]63
Electrical input frequency minimum [Hz]47
Electrical output frequency [Hz]50
Electrical output frequency for U/f control maximum [Hz]550
Electrical output frequency for U/f control minimum [Hz]0
Electrical output frequency for vector control maximum [Hz]200
Electrical output frequency for vector control minimum [Hz]0
Equipment marking acc. to DIN EN 81346-2Q
Height [mm]196
Ambient temperature during transport maximum [°C]70
IE class of the CDMIE2
Input current with high overload rated value [A]8.8
Input current with low overload rated value [A]10.1
Installation altitude at height above sea level without power reduction maximum [m]1000
Installation environment regarding EMC environment Ayes
Installation environment regarding EMC environment Bno
Mounting type Through-hole technologyno
Net weight [kg]1.5
Operating resource protection class acc. to EN 61800-5-1Class I (with protective bonding circuit) and Class III (PELV)
Output current rated value maximum [A]11.8
Ambient temperature during transport minimum [°C]-40
Output current with high overload rated value [A]5.9
Output current with low overload rated value [A]7.7
Output current without overload rated value [A]7.7
Output voltage rated value [V]400
Output voltage in percent related to the input voltage maximum [%]95
Output voltage in percent related to the input voltage minimum [%]0
Phase number of the input voltage3
Phase number of the output voltage3
Power factor0.85
Power loss [W] maximum [kW]0.12
Ambient temperature with high overload during operation maximum [°C]50
Power loss [W] of the CDM at the CDM operating point (0/100) [W]85
Power loss [W] of the CDM at the CDM operating point (0/25) [W]57
Power loss [W] of the CDM at the CDM operating point (0/50) [W]65
Power loss [W] of the CDM at the CDM operating point (50/100) [W]97
Power loss [W] of the CDM at the CDM operating point (50/25) [W]59
Power loss [W] of the CDM at the CDM operating point (50/50) [W]69
Power loss [W] of the CDM at the CDM operating point (90/100) [W]116
Power loss [W] of the CDM at the CDM operating point (90/50) [W]76
Power loss [W] of the CDM in standby mode [W]12
product brand nameSINAMICS
Ambient temperature with high overload during operation minimum [°C]-5
Product component Brake chopperyes
Product component Line filteryes
Product designationPM240-2
Product function 4 quadrant operationno
Product type designationG120
Protection class IPIP20
Protection function for converter Temperature monitoringyes
Protection function for motor Temperature monitoringyes
Protection function Ground fault protectionyes
Protection function Overload protectionyes
Ambient temperature with low overload during operation maximum [°C]40
Protection function Overvoltage protectionyes
Protection function parameter lockyes
Protection function Short-circuit protectionyes
Protection function Stall protectionyes
Protection function undervoltage protectionyes
Protection function with blocked rotoryes
Pulse frequency rated value [kHz]4
Ratio of converter losses/reference converter losses at the CDM operating point (90/100)67.71
Relative humidity without condensation during operation maximum [%]95
Relative humidity without condensation during operation maximum NoteRH, condensation not permitted

Delivery Information

Export Control RegulationsAL : 9I999KP / ECCN : N
Delivery Time3 Day/Days
Net Weight (lb)3,307 lb
Product Dimensions (W x L x H)Not available
Packaging Dimension3,543 x 7,283 x 11,024
Package size unit of measurein
Quantity Unit1 Piece
Packaging Quantity1

Additional Product Information

EAN4042948666012
UPC887621779993
Commodity Code85044084
LKZ_FDB/ CatalogIDD11.1SD
Product Group9772
Country of originGreat Britain
RoHS ComplianceSince: 07/01/2006
ReturnableNo
Obligation Category for taking back electrical and electronic equipment after useNo obligation to take back electrical and electronic equipment after use

Docs


Frequently bought together


Other SIEMENS items

Request a quote