Sinamics G120 Control Unit CU240E-2 PN E-Type Safety Integrated STO PROFINET 6DI, 3DO, 2AI, 2AO, MAX 1F-DI PTC/KTY Interface USB- and SD/MMC-Interface Protection IP20 Ambient Temperature 0 to +50 Degree C without Power Module and Panel
Specifications
Certifications | C-Tick |
---|---|
Current | .5 A |
Depth | 46 mm |
Height | 199 mm |
IP Rating | IP20 |
Max. Current | 0.5 A |
Max. Operating Temperature | 55 °C |
Min. Operating Temperature | -10 °C |
Number of Inputs | 6 |
Standard | C-Tick (RCM) |
Weight | .49 kg |
Width | 73 mm |
Specifications | |
Net Weight in Kg | 0.49 |
Ambient temperature [°F] during operation maximum Note | A derating of 3 K/1000 m has to be applied to the Control Units from an installation altitude of 1000 m above sea level |
Protocol is supported PROFIBus protocol | No |
Protocol is supported PROFINET CBA protocol | No |
Protocol is supported PROFINET IO protocol | No |
Protocol is supported PROFIsafe protocol | Yes |
Protocol is supported SafetyBus p protocol | No |
Protocol is supported SERCOS protocol | No |
Protocol is supported SUCONET protocol | No |
Protocol is supported TCP/IP | Yes |
Relative humidity maximum [%] | 95 |
Relative humidity maximum Note | RH, condensation not permitted |
Ambient temperature [°F] during operation minimum [°F] | 14 |
Type of analog input | Differential input |
Type of analog input Note | Switchable between voltage (-10 ... +10 V) and current (0/4 ... 20 mA) using a DIP switch |
Type of analog output | Non-isolated output |
Type of analog output Note | Switchable between voltage (0 ... 10 V) and current (0/4 ... 20 mA) using a parameter |
Width [mm] | 73 |
Ambient temperature [°F] during storage maximum [°F] | 158 |
Ambient temperature [°F] during storage minimum [°F] | -40 |
Application range | for modular Sinamics G120 inverters. |
AWG number as coded connectable conductor cross section for signal line maximum | 16 |
AWG number as coded connectable conductor cross section for signal line minimum | 30 |
Certificate of suitability | UL, cUL, CE, C-Tick (RCM) |
Certificate of suitability for CE marking | Low-voltage directive 2006/95/EC |
Connectable conductor cross-section for signal line maximum [mm2] | 1.5 |
Supplier | Siemens AG |
Connectable conductor cross-section for signal line minimum [mm2] | 0.05 |
Consumed current maximum [A] | 0.5 |
Cover version | No cover necessary |
Depth [mm] | 46 |
Design of the interface for bus system Integrated | PROFINET |
Design of the interface for bus system Integrated Note | 2 x RJ45, device name storable on device, max. 100 Mbits/s (Full Duplex) |
Design of the interface for control units | Basic Operator Panel BOP-2 or Intelligent Operator Panel IOP |
Design of the interface for PC interface | USB |
Design of the interface of the control unit of the storage medium | 1 Sinamics Micro Memory Card (MMC) or 1 Sinamics SD Card |
Design of the interface removable plug-in terminals | Yes |
Order number | 6SL3244-0BB12-1FA0 |
Design of the protective insulation | PELV according to EN 50178, safe disconnection from the mains by double/reinforced isolation |
Design of the sensor to detect the ambient temperature connectable | 1 motor temperature sensor input, sensors that can be connected: PTC, KTY and Thermo-Click, accuracy ±5 °C |
Equipment marking acc. to DIN EN 81346-2 | K |
Height [mm] | 199 |
Input current at digital standard inputs maximum [mA] | 15 |
Input voltage at analog inputs as voltage inputs for signal <0> to <1> [V] | 4 |
Input voltage at analog inputs as voltage inputs for signal <1> to <0> [V] | 1.6 |
Input voltage at digital standard inputs for signal <0> to <1> [V] | 11 |
Input voltage at digital standard inputs for signal <1> to <0> [V] | 5 |
Load at analog output when selecting operating mode: current mode maximum [Ohm] | 500 |
A/D resolution at the analog input [bit] | 10 |
Load at analog output when selecting operating mode: voltage mode minimum [kOhm] | 10 |
Net weight [kg] | 0.49 |
Number of analog inputs | 2 |
Number of analog inputs Note | The differential analog inputs can be configured as supplementary digital inputs |
Number of analog outputs | 2 |
Number of digital inputs | 6 |
Number of digital inputs Note | Optically isolated, free reference potential (own potential group), NPN/PNP-logic selectable via wiring |
Number of digital inputs with fail-safe | 1 |
Number of digital inputs with fail-safe Note | Use of 2 × DI Standard |
Number of digital outputs as relay change-over contact | 2 |
Ambient temperature during operation maximum [°C] | 55 |
Number of digital outputs as transistor | 1 |
Number of interfaces acc. to 20 mA (TTY) | 4 |
Number of interfaces acc. to Industrial Ethernet | 2 |
Number of interfaces acc. to PROFINET | 2 |
Number of interfaces acc. to RS 232 | 1 |
Number of interfaces acc. to RS 422 | 0 |
Number of interfaces acc. to RS 485 | 0 |
Number of interfaces acc. to USB | 1 |
Number of interfaces parallel | 0 |
Operating voltage from external supply voltage maximum [V] | 28.8 |
Ambient temperature during operation minimum [°C] | -10 |
Operating voltage from external supply voltage minimum [V] | 20.4 |
Operating voltage from power module [V] | 24 |
Output current at analog output when selecting operating mode: current mode [mA] | 20 |
Output current of digital outputs as relay change-over contact with resistive load at DC [A] | 0.5 |
Output current of digital outputs as transistor with resistive load at DC [A] | 0.5 |
Output voltage at analog output when selecting operating mode: voltage mode [V] | 10 |
Output voltage at the digital outputs as relay change-over contact with resistive load at DC [V] | 30 |
Output voltage of digital outputs as transistor with resistive load at DC [V] | 30 |
Power loss [W] maximum [W] | 5.5 |
product brandname | Sinamics |
Ambient temperature during storage maximum [°C] | 70 |
Product component optical interface | No |
Product component PC interface | Yes |
Product designation | CU240E-2 PN |
Product function for U/f control ECO mode linear or quadratic | Yes |
Product function for U/f control flux current control | Yes |
Product function for U/f control linear or quadratic parameterization | Yes |
Product function Torque control with encoder | No |
Product function Torque control without encoder | Yes |
Product function vector control with encoder | No |
Product function vector control without encoder | Yes |
Ambient temperature during storage minimum [°C] | -40 |
Product type designation | G120 |
Protection class IP | IP20 |
Protection function of analog input Overvoltage protection | Yes |
Protection function of analog input Overvoltage protection Note | Analog inputs are protected against inputs in a voltage range of ±30 V and have a common mode voltage in the range of ±15 V |
Protection function of analog outputs Short-circuit protection | Yes |
Protocol for bus system for integrated interface | PROFIdrive Profile V4.1 |
Protocol is supported AS-interface protocol | No |
Protocol is supported ASIsafe (Safety at work) protocol | No |
Protocol is supported CAN protocol | No |
Protocol is supported data highway protocol | No |
Ambient temperature [°F] during operation maximum [°F] | 131 |
Protocol is supported DeviceNet protocol | No |
Protocol is supported DeviceNet safety protocol | No |
Protocol is supported EIB/KNX protocol | No |
Protocol is supported EtherNet/IP protocol | Yes |
Protocol is supported Foundation Fieldbus protocol | No |
Protocol is supported INTERBus protocol | No |
Protocol is supported INTERBus safety protocol | No |
Protocol is supported LON protocol | No |
Protocol is supported MODBus protocol | No |
Protocol is supported other protocols | No |
Delivery Information | |
Export Control Regulations | AL : 9I999KP / ECCN : N |
Standard lead time ex-works | 10 Day/Days |
Net Weight (lb) | 1.08 lb |
Product Dimensions (W x L x H) | Not available |
Packaging Dimension | 3.661 x 9.449 x 2.677 |
Package size unit of measure | in |
Quantity Unit | 1 Piece |
Packaging Quantity | 1 |
Additional Product Information | |
EAN | 4042948661864 |
UPC | 40892941999 |
Commodity Code | 85049099 |
LKZ_FDB/ CatalogID | D11.1SD |
Product Group | 9779 |
Country of origin | Great Britain |
RoHS Compliance | Since: 07/01/2006 |
Returnable | Yes |
Obligation Category for taking back electrical and electronic equipment after use | No obligation to take back electrical and electronic equipment after use |