Variable speed drive, Altivar Machine ATV340, 22 kW Heavy Duty, 400 V, 3 phases, Ethernet
- Manufactured by:
- Schneider Electric
- Price (VAT excluded)
- € 4733.07
- Nuova Elva code
- ATV340D22N4E
- Manufacturer code
- ATV340D22N4E
- Availability
- Send request for quotation
This Altivar 340 variable speed drive can feed 3-phase synchronous and asynchronous motors in open and closed loop control. Altivar Machine ATV340 drives are sized heavy duty as standard. It works at a rated power up to 22kW / 30hp and a rated voltage from 380V to 480V AC. ATV340 has been designed to meet the needs of applications for harsh environments, such as vibration, shock and non-conductive dust and where high temperature resistance up to 60 °C is needed. This product integrates Modbus serial line communication protocols as standard. This drive features multi-protocol Ethernet embedded, it consists of Ethernet IP and Modbus TCP communication interfaces. it weighs 10.2kg and its dimensions are, 180mm wide, 385mm high, 249mm deep. ATV340 incorporates functions and features suitable for the most common applications, including packaging, material handling, material working, hoisting. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions), IEC 60721-3, IEC 61508, IEC 13849-1. It is also CE, UL, CSA, and TÜV certified. Accessories and options (encoder interface modules, I/O expansion modules, communication modules, braking resistors, line chokes, additional EMC filters) are available with Altivar Machine ATV340 drives, depending on the drive rating. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. It is fully integrated inside Schneider Electric’s EcoStruxure Machine through DTM. It is possible to configure, control, and diagnose ATV340 drives directly in SoMachine and SoMove software by means of the same software brick (DTM). It is eco-friendly and complies with directives such as RoHS relating to environmental protection.
Specifications
Certifications | CSA |
---|---|
Depth | 249.0 mm |
Height | 385.0 mm |
Mounting Type | Cabinet Mount |
Net Weight | 10.2 kg |
Number of Phases | 3 |
Standard | EN/IEC 61800-3 |
Storage Temperature | -40-70 °C |
Width | 180.0 mm |
Specifications | |
Variant | standard version |
Range Of Product | Altivar Machine ATV340 |
Motor Power Kw | 30 kW normal duty || 22 kW heavy duty |
[Us] Rated Supply Voltage | 380...480 V - 15...10 % |
Mounting Mode | cabinet mount |
Emc Filter | class C3 EMC filter integrated |
Product Or Component Type | variable speed drive |
Ip Degree Of Protection | IP20 |
Phase | 3 phase |
Communication Port Protocol | Modbus TCP || EtherNet/IP || Modbus serial |
Nominal Output Current | 46.0 A |
Product Specific Application | machine |
Maximum Horse Power Rating | 40 hp normal duty || 30 hp heavy duty |
Supply Frequency | 50...60 Hz +/- 5 % |
Complementary | |
Prospective Line Isc | 22 kA |
4 Quadrant Operation Possible | true |
Apparent Power | 45.1 kVA 480 V normal duty) || 42.1 kVA 480 V heavy duty) |
Net Weight | 10.2 kg |
With Safety Function Safe Direction (Sdi) | false |
Type Of Polarization | no impedance |
Relay Output Type | relay outputs R1A || relay outputs R1C 100000 cycles || relay outputs R2A || relay outputs R2C 100000 cycles |
Switching Frequency | 2...16 kHz adjustable || 6...16 kHz with derating factor |
Maximum Transient Current | 68.2 A 60 s normal duty) || 69 A 60 s heavy duty) || 83.7 A 2 s normal duty) || 83 A 2 s heavy duty) |
Analogue Input Number | 2 |
Motor Slip Compensation | automatic whatever the load || can be suppressed || adjustable || not available in permanent magnet motor law |
Power Dissipation In W | natural convection 28 W 380 V 4 kHz heavy duty) || forced convection 486 W 380 V 4 kHz heavy duty) || natural convection 39 W 380 V 4 kHz normal duty) || forced convection 631 W 380 V 4 kHz normal duty) |
Discrete Output Number | 2.0 |
With Safety Function Safe Position (Sp) | false |
Method Of Access | slave Modbus RTU || slave Modbus TCP |
With Safety Function Safely Limited Position (Slp) | false |
With Safety Function Safe Operating Stop (Sos) | false |
Number Of Addresses | 1-247 |
Discrete Input Number | 5 |
With Sft Fct Safe Stop 2 (Ss2) | false |
With Safety Function Safe Stop 1 (Ss1) | true |
Width | 180.0 mm |
Line Current | 60.1 A 380 V normal duty) || 48.6 A 480 V normal duty) || 63.5 A 380 V heavy duty) || 50.6 A 480 V heavy duty) |
Transmission Rate | 4.8 kbit/s || 9.6 kbit/s || 19.2 kbit/s || 38.4 kbit/s |
Depth | 249.0 mm |
Analogue Input Type | AI1 software-configurable current 0...20 mA 250 Ohm 12 bits || AI1 software-configurable temperature probe or water level sensor || AI1 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits || AI2 software-configurable voltage - 10...10 V DC 31.5 kOhm 12 bits |
Electrical Connection | control screw terminal 0.2...2.5 mm² AWG 24...AWG 12 || motor screw terminal 6...25 mm² AWG 8...AWG 3 || line side screw terminal 10...25 mm² AWG 6...AWG 3 || DC bus screw terminal 10...25 mm² AWG 6...AWG 3 |
Maximum Output Frequency | 0.599 kHz |
With Safety Function Safe Brake Management (Sbc/Sbt) | true |
Height | 385.0 mm |
Acceleration And Deceleration Ramps | S, U or customized || linear adjustable separately from 0.01...9999 s |
Maximum Output Voltage | 480 V |
Base Load Current At High Overload | 46.0 A |
Line Current | 63.5 A 380 V without line choke heavy duty) || 50.5 A 480 V without line choke heavy duty) || 67.9 A 480 V with external line choke normal duty) || 54.4 A 380 V with external line choke heavy duty) || 64.1 A 480 V with external line choke heavy duty) || 50.8 A 380 V with external line choke normal duty) |
Transmission Frame | RTU |
With Safety Function Safe Speed Monitor (Ssm) | false |
Relay Output Number | 2 |
With Safety Function Safe Torque Off (Sto) | true |
Data Format | 8 bits, configurable odd, even or no parity |
Base Load Current At Low Overload | 62.0 A |
Connector Type | 3 RJ45 |
Pollution Degree | 2 EN/IEC 61800-5-1 |
Analogue Output Number | 2 |
Physical Interface | 2-wire RS 485 |
Analogue Output Type | software-configurable voltage AQ1 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1 0...20 mA 500 Ohm 10 bits |
Minimum Switching Current | relay output R1B 5 mA 24 V DC || relay output R2C 5 mA 24 V DC |
Discrete Input Logic | 16 preset speeds |
Continuous Output Current | 62 A 4 kHz normal duty || 46 A 4 kHz heavy duty |
With Safety Function Safe Programmable Logic | false |
Brake Chopper Integrated | true |
Output Voltage | <= power supply voltage |
Nominal Switching Frequency | 4 kHz |
Braking To Standstill | by DC injection |
Discrete Input Type | PTI programmable as pulse input 0-30 kHz, 24 V DC 30 V) || DI1...DI5 safe torque off, 24 V DC 30 V)3.5 kOhm || programmable |
Protection Type | thermal protection motor || safe torque off motor || motor phase loss motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent drive || output overcurrent between motor phase and earth drive || output overcurrent between motor phases drive || short-circuit between motor phase and earth drive || short-circuit between motor phases drive || motor phase loss drive || DC Bus overvoltage drive || line supply overvoltage drive || line supply undervoltage drive || input supply loss drive || exceeding limit speed drive || break on the control circuit drive |
Discrete Output Type | programmable output DQ1, DQ2 30 V DC 100 mA |
With Safety Function Safely Limited Speed (Sls) | true |
Synchronous Motor Control Profile | permanent magnet motor || reluctance motor |
Electrical Connection | screw terminal 0.2...2.5 mm² control || screw terminal 6...25 mm² motor || screw terminal 10...25 mm² line side || screw terminal 10...25 mm² DC bus |
Maximum Switching Current | relay output R1C resistive, cos phi = 1 3 A 250 V AC || relay output R1C resistive, cos phi = 1 3 A 30 V DC || relay output R1C inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1C inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R2C resistive, cos phi = 1 5 A 250 V AC || relay output R2C resistive, cos phi = 1 5 A 30 V DC || relay output R2C inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R2C inductive, cos phi = 0.4 7 ms 2 A 30 V DC |
Asynchronous Motor Control Profile | optimized torque mode || constant torque standard || variable torque standard |
Offer Sustainability | |
Mercury Free | Yes |
Circularity Profile | ENVEOLI1609006EN |
Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
Weee | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
China Rohs Regulation | X |
Upgradeability | Upgraded components available |
Rohs Exemption Information | Yes |
Environmental Disclosure | ENVPEP1609006EN |
Sustainable Offer Status | Green Premium product |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Environment | |
Product Certifications | UL || CSA || TÜV || EAC || CTick |
Pollution Degree | 2 |
Electromagnetic Compatibility | electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5 || conducted radio-frequency immunity test level 3 IEC 61000-4-6 |
Ambient Air Temperature For Operation | -15-50 °C without derating vertical position) || 50-60 °C with derating factor vertical position) |
Volume Of Cooling Air | 128.0 m3/h |
Marking | CE |
Maximum Acceleration Under Vibrational Stress (During Operation) | 5 m/s² at 9...200 Hz |
Noise Level | 56.7 dB |
Ambient Air Temperature For Storage | -40-70 °C |
Type Of Cooling | forced convection |
Isolation | between power and control terminals |
Maximum Deflection Under Vibratory Load (During Operation) | 1.5 mm at 2...9 Hz |
Assembly Style | with heat sink |
Operating Position | vertical +/- 10 degree |
Ambient Air Transport Temperature | -40-70 °C |
Standards | EN/IEC 61800-3 || EN/IEC 61800-5-1 || IEC 60721-3 || IEC 61508 || IEC 13849-1 || UL 618000-5-1 || UL 508C |
Regulation Loop | adjustable PID regulator |
Permitted Relative Humidity (During Operation) | class 3K5 according to EN 60721-3 |
Operating Altitude | <= 9842.52 ft (3000 m) with current derating above 1000m |
Overvoltage Category | class III |
Environmental Class (During Operation) | class 3C3 according to IEC 60721-3-3 || class 3S3 according to IEC 60721-3-3 |
Maximum Acceleration Under Shock Impact (During Operation) | 70 m/s² at 22 ms |