Variable speed drive, Altivar Machine ATV340, 0.75 kW Heavy Duty, 400 V, 3 phases, Ethernet

Manufactured by:
Schneider Electric
Schneider electric

1b25d53868fb742348a46a9bbb28792b659c15dd medium
Price (VAT excluded)
€ 1013.79
Nuova Elva code
ATV340U07N4E
Manufacturer code
ATV340U07N4E
Availability
Standard lead time: 10 days

This Altivar 340 variable speed drive can feed 3-phase synchronous and asynchronous motors in open and closed loop control. Altivar Machine ATV340 drives are sized heavy duty as standard. It works at a rated power up to 0.75kW / 1hp and a rated voltage from 380V to 480V AC. ATV340 has been designed to meet the needs of applications for harsh environments, such as vibration, shock and non-conductive dust and where high temperature resistance up to 60 °C is needed. This product integrates Modbus serial line communication protocols as standard. This drive features multi-protocol Ethernet embedded, it consists of Ethernet IP and Modbus TCP communication interfaces. it weighs 1.7kg and its dimensions are, 85mm wide, 270mm high, 232.5mm deep. ATV340 incorporates functions and features suitable for the most common applications, including packaging, material handling, material working, hoisting. It conforms to international standards IEC/EN 61800-5-1 and IEC/EN 61800-3 (immunity and conducted and radiated EMC emissions), IEC 60721-3, IEC 61508, IEC 13849-1. It is also CE, UL, CSA, and TÜV certified. Accessories and options (encoder interface modules, I/O expansion modules, communication modules, braking resistors, line chokes, additional EMC filters) are available with Altivar Machine ATV340 drives, depending on the drive rating. It is designed to be mounted in vertical position (+/- 10 °) on a panel, thanks to 4 fixing holes. It is fully integrated inside Schneider Electric’s EcoStruxure Machine through DTM. It is possible to configure, control, and diagnose ATV340 drives directly in SoMachine and SoMove software by means of the same software brick (DTM). It is eco-friendly and complies with directives such as RoHS relating to environmental protection.

Specifications

CertificationsCSA
Depth232.5 mm
Height270.0 mm
Mounting TypeCabinet Mount
Net Weight1.7 kg
Number of Phases3
StandardEN/IEC 61800-3
Storage Temperature-40-70 °C
Width85.0 mm

Specifications

Variantstandard version
Range Of ProductAltivar Machine ATV340
Motor Power Kw1.1 kW normal duty || 0.75 kW heavy duty
[Us] Rated Supply Voltage380...480 V - 15...10 %
Mounting Modecabinet mount
Emc Filterclass C3 EMC filter integrated
Product Or Component Typevariable speed drive
Ip Degree Of ProtectionIP20
Phase3 phase
Communication Port ProtocolModbus TCP || Modbus serial || EtherNet/IP
Nominal Output Current2.2 A
Product Specific Applicationmachine
Maximum Horse Power Rating1.5 hp normal duty || 1 hp heavy duty
Supply Frequency50...60 Hz +/- 5 %

Complementary

Prospective Line Isc5 kA
4 Quadrant Operation Possibletrue
Apparent Power2.2 kVA 480 V normal duty) || 2.2 kVA 480 V heavy duty)
Net Weight1.7 kg
With Safety Function Safe Direction (Sdi)false
Type Of Polarizationno impedance
Relay Output Typerelay outputs R1A || relay outputs R1C 100000 cycles || relay outputs R2A || relay outputs R2C 100000 cycles
Switching Frequency2...16 kHz adjustable || 14...16 kHz with derating factor
Maximum Transient Current3.1 A 60 s normal duty) || 3.3 A 60 s heavy duty) || 3.8 A 2 s normal duty) || 4 A 2 s heavy duty)
Analogue Input Number2
Motor Slip Compensationautomatic whatever the load || adjustable || not available in permanent magnet motor law || can be suppressed
Power Dissipation In Wnatural convection 28 W 380 V 4 kHz heavy duty) || forced convection 28 W 380 V 4 kHz heavy duty) || natural convection 33 W 380 V 4 kHz normal duty) || forced convection 33 W 380 V 4 kHz normal duty)
Discrete Output Number2.0
With Safety Function Safe Position (Sp)false
Method Of Accessslave Modbus RTU || slave Modbus TCP
With Safety Function Safely Limited Position (Slp)false
With Safety Function Safe Operating Stop (Sos)false
Number Of Addresses1-247
Discrete Input Number5
With Sft Fct Safe Stop 2 (Ss2)false
With Safety Function Safe Stop 1 (Ss1)true
Width85.0 mm
Line Current2.6 A 380 V normal duty) || 2.1 A 480 V normal duty) || 3.4 A 380 V heavy duty) || 2.6 A 480 V heavy duty)
Transmission Rate4.8 kbit/s || 9.6 kbit/s || 19.2 kbit/s || 38.4 kbit/s
Depth232.5 mm
Analogue Input TypeAI1 software-configurable current 0...20 mA 250 Ohm 12 bits || AI1 software-configurable temperature probe or water level sensor || AI1 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits || AI2 software-configurable voltage - 10...10 V DC 31.5 kOhm 12 bits
Electrical Connectionline side screw terminal 1.5...4 mm² AWG 14...AWG 12 || DC bus screw terminal 4...6 mm² AWG 12...AWG 10 || motor screw terminal 1.5...4 mm² AWG 14...AWG 12 || control screw terminal 0.2...2.5 mm² AWG 24...AWG 12
Maximum Output Frequency0.599 kHz
With Safety Function Safe Brake Management (Sbc/Sbt)true
Height270.0 mm
Acceleration And Deceleration RampsS, U or customized || linear adjustable separately from 0.01...9999 s
Maximum Output Voltage480 V
Base Load Current At High Overload2.2 A
Line Current2.6 A 480 V without line choke heavy duty) || 2.6 A 380 V with external line choke normal duty) || 2.1 A 480 V with external line choke normal duty) || 1.9 A 380 V with external line choke heavy duty) || 1.6 A 480 V with external line choke heavy duty) || 3.4 A 380 V without line choke heavy duty)
Transmission FrameRTU
With Safety Function Safe Speed Monitor (Ssm)false
Relay Output Number2
With Safety Function Safe Torque Off (Sto)true
Data Format8 bits, configurable odd, even or no parity
Base Load Current At Low Overload2.8 A
Connector Type3 RJ45
Pollution Degree2 EN/IEC 61800-5-1
Analogue Output Number2
Physical Interface2-wire RS 485
Analogue Output Typesoftware-configurable voltage AQ1 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1 0...20 mA 500 Ohm 10 bits
Minimum Switching Currentrelay output R1B 5 mA 24 V DC || relay output R2C 5 mA 24 V DC
Discrete Input Logic16 preset speeds
Continuous Output Current2.2 A 4 kHz heavy duty || 2.8 A 4 kHz normal duty
With Safety Function Safe Programmable Logicfalse
Brake Chopper Integratedtrue
Output Voltage<= power supply voltage
Nominal Switching Frequency4 kHz
Braking To Standstillby DC injection
Discrete Input TypePTI programmable as pulse input 0-30 kHz, 24 V DC 30 V) || DI1...DI5 safe torque off, 24 V DC 30 V)3.5 kOhm || programmable
Protection Typethermal protection motor || safe torque off motor || motor phase loss motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent drive || output overcurrent between motor phase and earth drive || output overcurrent between motor phases drive || short-circuit between motor phase and earth drive || short-circuit between motor phases drive || motor phase loss drive || DC Bus overvoltage drive || line supply overvoltage drive || line supply undervoltage drive || input supply loss drive || exceeding limit speed drive || break on the control circuit drive
Discrete Output Typeprogrammable output DQ1, DQ2 30 V DC 100 mA
With Safety Function Safely Limited Speed (Sls)true
Synchronous Motor Control Profilereluctance motor || permanent magnet motor
Electrical Connectionscrew terminal 1.5...4 mm² line side || screw terminal 4...6 mm² DC bus || screw terminal 1.5...4 mm² motor || screw terminal 0.2...2.5 mm² control
Maximum Switching Currentrelay output R1C resistive, cos phi = 1 3 A 250 V AC || relay output R1C resistive, cos phi = 1 3 A 30 V DC || relay output R1C inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1C inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R2C resistive, cos phi = 1 5 A 250 V AC || relay output R2C resistive, cos phi = 1 5 A 30 V DC || relay output R2C inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R2C inductive, cos phi = 0.4 7 ms 2 A 30 V DC
Asynchronous Motor Control Profileconstant torque standard || variable torque standard || optimized torque mode

Offer Sustainability

Mercury FreeYes
Circularity ProfileENVEOLI1609005EN
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)
Reach RegulationReference contains Substances of Very High Concern above the threshold
WeeeThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs RegulationX
UpgradeabilityUpgraded components available
Rohs Exemption InformationYes
Environmental DisclosureENVPEP1609005EN
Sustainable Offer StatusGreen Premium product
California Proposition 65WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Environment

Product CertificationsUL || CSA || TÜV || EAC || CTick
Pollution Degree2
Electromagnetic Compatibilityelectrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5 || conducted radio-frequency immunity test level 3 IEC 61000-4-6
Ambient Air Temperature For Operation-15-50 °C without derating vertical position) || 50-60 °C with derating factor vertical position)
Volume Of Cooling Air18.0 m3/h
MarkingCE
Maximum Acceleration Under Vibrational Stress (During Operation)5 m/s² at 9...200 Hz
Noise Level52.7 dB
Ambient Air Temperature For Storage-40-70 °C
Type Of Coolingforced convection
Isolationbetween power and control terminals
Maximum Deflection Under Vibratory Load (During Operation)1.5 mm at 2...9 Hz
Assembly Stylewith heat sink
Operating Positionvertical +/- 10 degree
Ambient Air Transport Temperature-40-70 °C
StandardsEN/IEC 61800-3 || EN/IEC 61800-5-1 || IEC 60721-3 || IEC 61508 || IEC 13849-1 || UL 618000-5-1 || UL 508C
Regulation Loopadjustable PID regulator
Permitted Relative Humidity (During Operation)class 3K5 according to EN 60721-3
Operating Altitude<= 9842.52 ft (3000 m) with current derating above 1000m
Overvoltage Categoryclass III
Environmental Class (During Operation)class 3C3 according to IEC 60721-3-3 || class 3S3 according to IEC 60721-3-3
Maximum Acceleration Under Shock Impact (During Operation)70 m/s² at 22 ms

Docs