Variable speed drive, Altivar Process ATV600, ATV630, 1.5kW/2 hp, 380...480 V, IP21/UL type 1

Manufactured by:
Schneider Electric
Schneider electric

4bee2608484a9f95534d47c0f0f73204727edb76 medium
Price (VAT excluded)
€ 886.04
Nuova Elva code
ATV630U15N4
Manufacturer code
ATV630U15N4
Availability
Send request for quotation

This Altivar Process ATV600 variable speed drive can feed 3-phase synchronous and asynchronous power motors. It features 3 built-in RJ45 communication ports as standard, 1 Ethernet port, 2 serial ports. It works at a rated supply voltage from 380V to 480V AC. This drive provides up to 30% energy saving when on standby due to the innovative ‘‘Stop and Go’’operation without additional costs. It is suitable for motors with power rating up to 1.5kW / 2hp for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 0.75kW / 1hp for applications requiring significant overload (up to 150%). It weighs 4.5kg and its dimensions are, 144mm wide, 350mm high, 203mm deep. This drive is focused on fluids management processing and energy saving, it offers extensive flexibility in water and wastewater, mining, minerals and metals, oil and gas and food and beverage applications. Accessories (fan kit, graphic display terminal) and options (I/O expansion modules, communication modules, EMC input filters) are available with Altivar Process ATV600 drives, depending on the drive rating. It is designed to be mounted in vertical position (+/- 10 °) on a wall. This new concept of drives meets the major needs of process and utilities in terms of equipment efficiency and total cost of ownership by supporting the energy management, asset management and also the overall performance of the process.

Specifications

CertificationsATEX INERIS
Depth203 mm
Height350 mm
Mounting TypeWall-Mounted
Net Weight4.5 kg
Number of Phases3
StandardEN/IEC 61800-3
Storage Temperature-40-70 °C
Width144 mm

Specifications

Prospective Line Isc50 kA
Communication Port ProtocolModbus TCP || Ethernet || Modbus serial
Product Specific Applicationprocess and utilities
Safety FunctionSTO (safe torque off) SIL 3
Maximum Horse Power Rating2 hp normal duty || 1 hp heavy duty
Supply Frequency50...60 Hz - 5...5 %
Option Cardslot A communication module, Profibus DP V1 || slot A communication module, PROFINET || slot A communication module, DeviceNet || slot A communication module, Modbus TCP/EtherNet/IP || slot A communication module, CANopen daisy chain RJ45 || slot A communication module, CANopen SUB-D 9 || slot A communication module, CANopen screw terminals || slot A/slot B digital and analog I/O extension module || slot A/slot B output relay extension module || slot A communication module, Ethernet IP/Modbus TCP/MD-Link || communication module, BACnet MS/TP || communication module, Ethernet Powerlink
Degree Of ProtectionUL type 1 UL 508C
Range Of ProductAltivar Process ATV600
Speed Drive Output Frequency0.1-500 Hz
Ip Degree Of ProtectionIP21IEC 61800-5-1 || IP21IEC 60529
Product Destinationasynchronous motors || synchronous motors
Motor Power Kw1.5 kW normal duty) || 0.75 kW heavy duty)
[Us] Rated Supply Voltage380...480 V
Maximum Transient Current4.4 A 60 s normal duty) || 3.3 A 60 s heavy duty)
[Us] Rated Supply Voltage380...480 V - 15...10 %
Discrete Input Logic16 preset speeds
Type Of Coolingforced convection
Continuous Output Current4 A 4 kHz normal duty || 2.2 A 4 kHz heavy duty
Nominal Switching Frequency4 kHz
Device Short NameATV630
Synchronous Motor Control Profilepermanent magnet motor || synchronous reluctance motor
Line Current3 A 380 V normal duty) || 2.6 A 480 V normal duty) || 1.7 A 380 V heavy duty) || 1.5 A 480 V heavy duty)
Emc Filterintegrated 50 m EN/IEC 61800-3 category C2 || integrated 150 m EN/IEC 61800-3 category C3
Asynchronous Motor Control Profilevariable torque standard || constant torque standard || optimized torque mode
Variantstandard version
Product Or Component Typevariable speed drive
Apparent Power2.2 kVA 480 V normal duty) || 1.2 kVA 480 V heavy duty)
Switching Frequency2...12 kHz adjustable || 4...12 kHz with derating factor

Complementary

Discrete Input Logicpositive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V
Relay Output Typeconfigurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 100000 cycles || configurable relay logic R3 sequence relay NO 100000 cycles
Frequency Resolutiondisplay unit 0.1 Hz || analog input 0.012/50 Hz
Analogue Input Number3
Motor Slip Compensationcan be suppressed || adjustable || not available in permanent magnet motor law || automatic whatever the load
Discrete Output Number0
Method Of Accessslave Modbus TCP
Discrete Input Number8
Local Signallingfor local diagnostic 3 LEDs || for embedded communication status 3 LEDs (dual colour) || for communication module status 4 LEDs (dual colour) || for presence of voltage 1 LED (red)
Linearity ErrorAI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AO1, AO2 +/- 0.2 % analog output
Number Of Addresses1-247 Modbus serial
Analogue Output Typesoftware-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 10 bits || software-configurable current DQ-, DQ+ 30 V DC || software-configurable current DQ-, DQ+ 100 mA
Width144 mm
Transmission Rate10, 100 Mbits || 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
Depth203 mm
Analogue Input TypeAI1, AI2, AI3 software-configurable voltage 0...10 V DC 31.5 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA 250 Ohm 12 bits || AI2 voltage analog input - 10...10 V DC 31.5 kOhm 12 bits
Discrete And Process Manufacturingbuilding - HVAC compressor centrifugal || food and beverage processing other application || mining mineral and metal fan || mining mineral and metal pump || oil and gas fan || water and waste water other application || building - HVAC screw compressor || food and beverage processing pump || food and beverage processing fan || food and beverage processing atomization || oil and gas electro submersible pump (ESP) || oil and gas water injection pump || oil and gas jet fuel pump || oil and gas compressor for refinery || water and waste water centrifuge pump || water and waste water positive displacement pump || water and waste water electro submersible pump (ESP) || water and waste water screw pump || water and waste water lobe compressor || water and waste water screw compressor || water and waste water compressor centrifugal || water and waste water fan || water and waste water conveyor || water and waste water mixer
Sampling Duration2 ms +/- 0.5 ms DI1...DI4) - discrete input || 5 ms +/- 1 ms DI5, DI6) - discrete input || 5 ms +/- 0.1 ms AI1, AI2, AI3) - analog input || 10 ms +/- 1 ms AO1) - analog output
Electrical Connectioncontrol removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 || motor screw terminal 2.5...6 mm² AWG 14...AWG 10 || line side screw terminal 2.5...6 mm² AWG 14...AWG 10
Maximum Output Frequency500 kHz
Height350 mm
Acceleration And Deceleration Rampslinear adjustable separately from 0.01...9999 s
Discrete Output Typerelay outputs R1A, R1B, R1C 250 V AC 3000 mA || relay outputs R1A, R1B, R1C 30 V DC 3000 mA || relay outputs R2A, R2C 250 V AC 5000 mA || relay outputs R2A, R2C 30 V DC 5000 mA || relay outputs R3A, R3C 250 V AC 5000 mA || relay outputs R3A, R3C 30 V DC 5000 mA
Transmission FrameRTU
Relay Output Number3
Data Format8 bits, configurable odd, even or no parity
Accuracy+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
Connector TypeRJ45 on the remote graphic terminal)Ethernet/Modbus TCP || RJ45 on the remote graphic terminal)Modbus serial
Input CompatibilityDI1...DI6 discrete input level 1 PLC EN/IEC 61131-2 || DI5, DI6 discrete input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC EN/IEC 61131-2
Permissible Temporary Current Boost1.1 x In 60 s normal duty) || 1.5 x In 60 s heavy duty)
Mounting Modewall mount
Analogue Output Number2
Physical InterfaceEthernet || 2-wire RS 485
Maximum Switching Currentrelay output R1, R2, R3 resistive, cos phi = 1 3 A 250 V AC || relay output R1, R2, R3 resistive, cos phi = 1 3 A 30 V DC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1, R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC
Minimum Switching Currentrelay output R1, R2, R3 5 mA 24 V DC
Refresh Timerelay output R1, R2, R3)5 ms +/- 0.5 ms)
Enclosure Mountingwall mounted
Isolationbetween power and control terminals
Output Voltage<= power supply voltage
Quantity Per Set1
Braking To Standstillby DC injection
Discrete Input TypeDI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V)
Protection Typethermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-circuit protection drive || motor phase break drive || overvoltages on the DC bus drive || line supply overvoltage drive || line supply undervoltage drive || line supply phase loss drive || overspeed drive || break on the control circuit drive
Supplyexternal supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for digital inputs and STO 24 V DC 21-27 V), <200 mA overload and short-circuit protection
Exchange Modehalf duplex, full duplex, autonegotiation Ethernet/Modbus TCP
Power Range1.1-2 kW 380-440 V 3 phase || 1.1-2 kW 480-500 V 3 phase
Phase3 phase
Net Weight4.5 kg
Type Of Polarizationno impedance

Offer Sustainability

Mercury FreeYes
Circularity ProfileENVEOLI1501005EN
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)
Reach RegulationReference contains Substances of Very High Concern above the threshold
WeeeThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs RegulationX
UpgradeabilityUpgraded components available
Rohs Exemption InformationYes
Environmental DisclosureENVPEP1501005EN
Sustainable Offer StatusGreen Premium product
California Proposition 65WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Environment

Product CertificationsATEX INERIS || DNV-GL || ATEX zone 2/22 || UL || CSA || TÜV
Overvoltage CategoryIII
StandardsUL 508C || EN/IEC 61800-3 || environment 1 category C2 EN/IEC 61800-3 || environment 2 category C3 EN/IEC 61800-3 || EN/IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
Pollution Degree2
Electromagnetic Compatibilityelectrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5 || conducted radio-frequency immunity test level 3 IEC 61000-4-6
Ambient Air Temperature For Operation-15-50 °C without derating) || 50-60 °C with derating factor)
Volume Of Cooling Air38 m3/h
MarkingCE
Pollution Degree2 EN/IEC 61800-5-1
Noise Level54.5 dB
Ambient Air Temperature For Storage-40-70 °C
Power Dissipation In Wnatural convection 28 W 380 V 4 kHz || forced convection 41 W 380 V 4 kHz
Relative Humidity5-95 % without condensation IEC 60068-2-3
Operating Positionvertical +/- 10 degree
Maximum Thdi<48 % full load IEC 61000-3-12
StandardsUL 508C || EN/IEC 61800-3 || EN/IEC 61800-3 environment 1 category C2 || EN/IEC 61800-3 environment 2 category C3 || EN/IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
Insulation Resistance> 1 MOhm 500 V DC for 1 minute to earth
Shock Resistance15 gn 11 ms IEC 60068-2-27
Vibration Resistance1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
Noise Level54.5 dB 86/188/EEC
Regulation Loopadjustable PID regulator
Operating Altitude<= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m