Variable speed drive, Altivar Process ATV900, ATV930, 2,2 kW, 200/240 V, with braking unit, IP21

Manufactured by:
Schneider Electric
Schneider electric

Dcda2e03dab3d778a3333e3e7e694f57f8a7aaf1 medium
Price (VAT excluded)
€ 937.70
Nuova Elva code
ATV930U22M3
Manufacturer code
ATV930U22M3
Availability
Send request for quotation

This Altivar Process ATV900 variable speed drive can feed 3-phase synchronous and asynchronous power motors. It is suitable for motors with power rating up to 2.2kW/3HP for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 1.5kW/2HP for applications requiring significant overload (up to 150%). It works at a rated supply voltage from 200Vac to 240Vac. This variable speed / frequency drive (VSD / VFD) is specifically designed for industrial processes. In the following market segments: oil and gas, mining, minerals and metals, food and beverage water and wastewater. It offers high motor performance on any motor and total control of any kind of coupling in master/slave applications. Network services help ensure operation continuity even in case of connection breakdown. Web server and data logging help reduce downtime through fast troubleshooting and preventive maintenance. Its advanced connectivity, including EtherNet/IP and Modbus TCP, allows deep integration into automation architectures.

Specifications

CertificationsCSA
Depth206 mm
Height350 mm
Mounting TypeWall-Mounted
Net Weight4.5 kg
Number of Phases3
StandardEN/IEC 61800-3
Storage Temperature-40-70 °C
Width144 mm

Specifications

Prospective Line Isc50 kA
Ip Degree Of ProtectionIP21
Switching Frequency2...16 kHz adjustable || 4...16 kHz with derating factor
Maximum Transient Current13.4 A 60 s normal duty) || 12 A 60 s heavy duty)
Communication Port ProtocolModbus serial || EtherNet/IP || Modbus TCP
Product Specific Applicationprocess for industrial
Maximum Horse Power Rating3.0 hp normal duty || 2.0 hp heavy duty
Option Cardslot A communication module Profibus DP V1 || slot A communication module PROFINET || slot A communication module DeviceNet || slot A communication module EtherCAT || slot A communication module CANopen daisy chain RJ45 || slot A communication module CANopen SUB-D 9 || slot A communication module CANopen screw terminals || slot A/slot B/slot C digital and analog I/O extension module || slot A/slot B/slot C output relay extension module || slot B 5/12 V digital encoder interface module || slot B analog encoder interface module || slot B resolver encoder interface module || communication module Ethernet Powerlink
Degree Of ProtectionUL type 1
Maximum Output Frequency599 Hz
Range Of ProductAltivar Process ATV900
Network Frequency50-60 Hz
Motor Power Kw2.2 kW normal duty || 1.5 kW heavy duty
[Us] Rated Supply Voltage200...240 V - 15...10 %
Mounting Modewall mount
Discrete Input Logic16 preset speeds
Continuous Output Current11.2 A 4 kHz normal duty || 8 A 4 kHz heavy duty
Nominal Switching Frequency4 kHz
Emc Filterintegrated || with EMC plate option
Device ApplicationIndustrial Application
Synchronous Motor Control Profilepermanent magnet motor || synchronous reluctance motor
Product Destinationasynchronous motors || synchronous motors
Line Current8.4 A 200 V normal duty) || 6.0 A 200 V heavy duty) || 7.2 A 240 V normal duty) || 5.3 A 240 V heavy duty)
Phase3 phase
Asynchronous Motor Control Profileoptimized torque mode || variable torque standard || constant torque standard
Variantwith braking chopper || standard version
Product Or Component Typevariable speed drive
Apparent Power3 kVA 240 V normal duty) || 2.2 kVA 240 V heavy duty)

Complementary

Discrete Input Logicpositive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V || positive logic (source) DI7, DI8), < 0.6 V, > 2.5 V || positive logic (source) STOA, STOB), < 5 V, > 11 V
Relative Symmetric Network Frequency Tolerance5 %
Net Weight4.5 kg
With Safety Function Safe Direction (Sdi)false
Type Of Polarizationno impedance
Relay Output Typeconfigurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 1000000 cycles || configurable relay logic R3 sequence relay NO 1000000 cycles
Analogue Input Number3
Motor Slip Compensationnot available in permanent magnet motor law || can be suppressed || adjustable || automatic whatever the load
Discrete Output Number2
With Safety Function Safe Position (Sp)false
Transmission Rate10/100 Mbit/s Ethernet IP/Modbus TCP || 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial
Power Dissipation In Wnatural convection 32 W 200 V 4 kHz || forced convection 74 W 200 V 4 kHz
Method Of Accessslave Modbus TCP
With Safety Function Safely Limited Position (Slp)false
With Safety Function Safe Operating Stop (Sos)false
Number Of Addresses1-247
Discrete Input Number10
Linearity ErrorAI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AQ1, AQ2 +/- 0.2 % analog output
Number Of Addresses1-247 Modbus serial
With Sft Fct Safe Stop 2 (Ss2)false
With Safety Function Safe Stop 1 (Ss1)true
Width144 mm
Analogue Output Typesoftware-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits
Transmission Rate10, 100 Mbits || 4.8 kbps || 9600 bit/s || 19200 bit/s
Depth206 mm
Analogue Input TypeAI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits
Sampling Duration2 ms +/- 0.5 ms DI1...DI8) - discrete input || 5 ms +/- 1 ms DI7, DI8) - pulse input || 1 ms +/- 1 ms AI1, AI2, AI3) - analog input || 5 ms +/- 1 ms AQ1, AQ2) - analog output
Electrical Connectioncontrol screw terminal 0.5...1.5 mm² AWG 20...AWG 16 || line side screw terminal 2.5...6 mm² AWG 14...AWG 10 || motor screw terminal 2.5...6 mm² AWG 14...AWG 10 || DC bus screw terminal 2.5...6 mm² AWG 14...AWG 10
With Safety Function Safe Brake Management (Sbc/Sbt)true
Height350 mm
Acceleration And Deceleration Rampslinear adjustable separately from 0.01...9999 s
Maximum Output Voltage240.0 V
Base Load Current At High Overload8.0 A
Discrete Output Typelogic output DQ+ 0-1 kHz <= 30 V DC 100 mA || programmable as pulse output DQ+ 0-30 kHz <= 30 V DC 20 mA || logic output DQ- 0-1 kHz <= 30 V DC 100 mA
Transmission FrameRTU
With Safety Function Safe Speed Monitor (Ssm)false
Relay Output Number3
With Safety Function Safe Torque Off (Sto)true
Data Format8 bits, configurable odd, even or no parity
Base Load Current At Low Overload11.2 A
Accuracy+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
Input CompatibilityDI1...DI8 discrete input level 1 PLC EN/IEC 61131-2 || DI7, DI8 pulse input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC EN/IEC 61131-2
Connector Type2 RJ45 || 1 RJ45
Analogue Output Number2
Maximum Switching Currentrelay output R1 resistive, cos phi = 1 3 A 250 V AC || relay output R1 resistive, cos phi = 1 3 A 30 V DC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R2, R3 resistive, cos phi = 1 5 A 250 V AC || relay output R2, R3 resistive, cos phi = 1 5 A 30 V DC || relay output R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC
Physical InterfaceEthernet || 2-wire RS 485
Minimum Switching Currentrelay output R1, R2, R3 5 mA 24 V DC
Refresh Timerelay output R1, R2, R3)5 ms +/- 0.5 ms)
Isolationbetween power and control terminals
With Safety Function Safe Programmable Logicfalse
Brake Chopper Integratedtrue
Quantity Per Set1
Type Of Polarizationno impedance Modbus serial
Braking To Standstillby DC injection
Discrete Input TypeDI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm || DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V) || STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm
4 Quadrant Operation Possibletrue
Protection Typethermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-circuit protection drive || motor phase break drive || overvoltages on the DC bus drive || line supply overvoltage drive || line supply undervoltage drive || line supply phase loss drive || overspeed drive || break on the control circuit drive
Supplyexternal supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for digital inputs and STO 24 V DC 21-27 V), <200 mA overload and short-circuit protection
With Safety Function Safely Limited Speed (Sls)true
Exchange Modehalf duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
Local Signallinglocal diagnostic 3 LED mono/dual colour) || embedded communication status 5 LED dual colour) || communication module status 2 LED dual colour) || presence of voltage 1 LED red)
Data Format8 bits, configurable odd, even or no parity Modbus serial

Offer Sustainability

Mercury FreeYes
Circularity ProfileENVEOLI1501005EN
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)
Reach RegulationReference contains Substances of Very High Concern above the threshold
WeeeThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs RegulationX
UpgradeabilityUpgraded components available
Rohs Exemption InformationYes
Environmental DisclosureENVPEP1501005EN
Sustainable Offer StatusGreen Premium product
California Proposition 65WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Environment

Product CertificationsUL || CSA || TÜV
Permitted Relative Humidity (During Operation)class 3K5 according to EN 60721-3
Operating Altitude<= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m
Overvoltage CategoryIII
Environmental Class (During Operation)class 3C3 according to IEC 60721-3-3 || class 3S3 according to IEC 60721-3-3
Maximum Acceleration Under Shock Impact (During Operation)150 m/s² at 11 ms
Pollution Degree2
Electromagnetic Compatibilityelectrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5 || conducted radio-frequency immunity test level 3 IEC 61000-4-6
Ambient Air Temperature For Operation-15-50 °C without derating) || 50-60 °C with derating factor)
Volume Of Cooling Air38 m3/h
MarkingCE
Maximum Deflection Under Vibratory Load (During Operation)1.5 mm at 2...13 Hz
Maximum Acceleration Under Vibrational Stress (During Operation)10 m/s² at 13...200 Hz
Noise Level54.5 dB
Ambient Air Temperature For Storage-40-70 °C
Relative Humidity5-95 % without condensation IEC 60068-2-3
Assembly Styleenclosed
Operating Positionvertical +/- 10 degree
Maximum Thdi<48 % full load IEC 61000-3-12
Ambient Air Transport Temperature-40-70 °C
StandardsUL 508C || EN/IEC 61800-3 || EN/IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1
Insulation Resistance> 1 MOhm 500 V DC for 1 minute to earth
Shock Resistance15 gn 11 ms IEC 60068-2-27
Environmental Characteristicchemical pollution resistance class 3C3 EN/IEC 60721-3-3 || dust pollution resistance class 3S3 EN/IEC 60721-3-3
Vibration Resistance1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6
Noise Level54.5 dB 86/188/EEC
Regulation Loopadjustable PID regulator

Docs


Other Schneider Electric items

Request a quote