Variable speed drive, Altivar Process ATV900, ATV930, 7,5 kW, 200/240 V, with braking unit, IP21
- Manufactured by:
- Schneider Electric
- Price (VAT excluded)
- € 1941.22
- Nuova Elva code
- ATV930U75M3
- Manufacturer code
- ATV930U75M3
- Availability
- Send request for quotation
This Altivar Process ATV900 variable speed drive can feed 3-phase synchronous and asynchronous power motors. It is suitable for motors with power rating up to 7.5kW/10HP for applications requiring slight overload (up to 120%). It is suitable for motors with power rating up to 5.5kW/7.5HP for applications requiring significant overload (up to 150%). It works at a rated supply voltage from 200Vac to 240Vac. This variable speed / frequency drive (VSD / VFD) is specifically designed for industrial processes. In the following market segments: oil and gas, mining, minerals and metals, food and beverage water and wastewater. It offers high motor performance on any motor and total control of any kind of coupling in master/slave applications. Network services help ensure operation continuity even in case of connection breakdown. Web server and data logging help reduce downtime through fast troubleshooting and preventive maintenance. Its advanced connectivity, including EtherNet/IP and Modbus TCP, allows deep integration into automation architectures.
Specifications
Certifications | CSA |
---|---|
Depth | 235 mm |
Height | 545.9 mm |
Mounting Type | Wall-Mounted |
Net Weight | 13.8 kg |
Number of Phases | 3 |
Standard | EN/IEC 61800-3 |
Storage Temperature | -40-70 °C |
Width | 211 mm |
Specifications | |
Prospective Line Isc | 50 kA |
Ip Degree Of Protection | IP21 |
Switching Frequency | 2...16 kHz adjustable || 4...16 kHz with derating factor |
Maximum Transient Current | 39.2 A 60 s normal duty) || 38.1 A 60 s heavy duty) |
Communication Port Protocol | Modbus serial || EtherNet/IP || Modbus TCP |
Product Specific Application | process for industrial |
Maximum Horse Power Rating | 10.0 hp normal duty || 7.5 hp heavy duty |
Option Card | slot A communication module Profibus DP V1 || slot A communication module PROFINET || slot A communication module DeviceNet || slot A communication module EtherCAT || slot A communication module CANopen daisy chain RJ45 || slot A communication module CANopen SUB-D 9 || slot A communication module CANopen screw terminals || slot A/slot B/slot C digital and analog I/O extension module || slot A/slot B/slot C output relay extension module || slot B 5/12 V digital encoder interface module || slot B analog encoder interface module || slot B resolver encoder interface module || communication module Ethernet Powerlink |
Degree Of Protection | UL type 1 |
Maximum Output Frequency | 599 Hz |
Range Of Product | Altivar Process ATV900 |
Network Frequency | 50-60 Hz |
Motor Power Kw | 7.5 kW normal duty || 5.5 kW heavy duty |
[Us] Rated Supply Voltage | 200...240 V - 15...10 % |
Mounting Mode | wall mount |
Discrete Input Logic | 16 preset speeds |
Continuous Output Current | 32.7 A 4 kHz normal duty || 25.4 A 4 kHz heavy duty |
Nominal Switching Frequency | 4 kHz |
Emc Filter | integrated || with EMC plate option |
Device Application | Industrial Application |
Synchronous Motor Control Profile | permanent magnet motor || synchronous reluctance motor |
Product Destination | synchronous motors || asynchronous motors |
Line Current | 27.1 A 200 V normal duty) || 20.1 A 200 V heavy duty) || 22.6 A 240 V normal duty) || 16.9 A 240 V heavy duty) |
Phase | 3 phase |
Asynchronous Motor Control Profile | variable torque standard || constant torque standard || optimized torque mode |
Variant | with braking chopper || standard version |
Product Or Component Type | variable speed drive |
Apparent Power | 9.9 kVA 240 V normal duty) || 7.6 kVA 240 V heavy duty) |
Complementary | |
Discrete Input Logic | positive logic (source) DI1...DI8), < 5 V, > 11 V || negative logic (sink) DI1...DI8), > 16 V, < 10 V || positive logic (source) DI7, DI8), < 0.6 V, > 2.5 V || positive logic (source) STOA, STOB), < 5 V, > 11 V |
Relative Symmetric Network Frequency Tolerance | 5 % |
Net Weight | 13.8 kg |
With Safety Function Safe Direction (Sdi) | false |
Type Of Polarization | no impedance |
Relay Output Type | configurable relay logic R1 fault relay NO/NC 100000 cycles || configurable relay logic R2 sequence relay NO 1000000 cycles || configurable relay logic R3 sequence relay NO 1000000 cycles |
Analogue Input Number | 3 |
Motor Slip Compensation | adjustable || can be suppressed || automatic whatever the load || not available in permanent magnet motor law |
Discrete Output Number | 2 |
With Safety Function Safe Position (Sp) | false |
Transmission Rate | 10/100 Mbit/s Ethernet IP/Modbus TCP || 4.8, 9.6, 19.2, 38.4 kbit/s Modbus serial |
Power Dissipation In W | forced convection 310 W 200 V 4 kHz || natural convection 51 W 200 V 4 kHz |
Method Of Access | slave Modbus TCP |
With Safety Function Safely Limited Position (Slp) | false |
With Safety Function Safe Operating Stop (Sos) | false |
Number Of Addresses | 1-247 |
Discrete Input Number | 10 |
Linearity Error | AI1, AI2, AI3 +/- 0.15 % of maximum value analog input || AQ1, AQ2 +/- 0.2 % analog output |
Number Of Addresses | 1-247 Modbus serial |
With Sft Fct Safe Stop 2 (Ss2) | false |
With Safety Function Safe Stop 1 (Ss1) | true |
Width | 211 mm |
Analogue Output Type | software-configurable voltage AQ1, AQ2 0...10 V DC 470 Ohm 10 bits || software-configurable current AQ1, AQ2 0...20 mA 500 Ohm 10 bits |
Transmission Rate | 10, 100 Mbits || 4.8 kbps || 9600 bit/s || 19200 bit/s |
Depth | 235 mm |
Analogue Input Type | AI1, AI2, AI3 software-configurable voltage 0...10 V DC 30 kOhm 12 bits || AI1, AI2, AI3 software-configurable current 0...20 mA/4...20 mA 250 Ohm 12 bits |
Sampling Duration | 2 ms +/- 0.5 ms DI1...DI8) - discrete input || 5 ms +/- 1 ms DI7, DI8) - pulse input || 1 ms +/- 1 ms AI1, AI2, AI3) - analog input || 5 ms +/- 1 ms AQ1, AQ2) - analog output |
Electrical Connection | control screw terminal 0.5...1.5 mm² AWG 20...AWG 16 || line side screw terminal 10...16 mm² AWG 8...AWG 6 || motor screw terminal 10...16 mm² AWG 8...AWG 6 || DC bus screw terminal 10...16 mm² AWG 8...AWG 6 |
With Safety Function Safe Brake Management (Sbc/Sbt) | true |
Height | 545.9 mm |
Acceleration And Deceleration Ramps | linear adjustable separately from 0.01...9999 s |
Maximum Output Voltage | 240.0 V |
Base Load Current At High Overload | 25.4 A |
Discrete Output Type | logic output DQ+ 0-1 kHz <= 30 V DC 100 mA || programmable as pulse output DQ+ 0-30 kHz <= 30 V DC 20 mA || logic output DQ- 0-1 kHz <= 30 V DC 100 mA |
Transmission Frame | RTU |
With Safety Function Safe Speed Monitor (Ssm) | false |
Relay Output Number | 3 |
With Safety Function Safe Torque Off (Sto) | true |
Data Format | 8 bits, configurable odd, even or no parity |
Base Load Current At Low Overload | 32.7 A |
Accuracy | +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input || +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output |
Input Compatibility | DI1...DI8 discrete input level 1 PLC EN/IEC 61131-2 || DI7, DI8 pulse input level 1 PLC IEC 65A-68 || STOA, STOB discrete input level 1 PLC EN/IEC 61131-2 |
Connector Type | 2 RJ45 || 1 RJ45 |
Analogue Output Number | 2 |
Maximum Switching Current | relay output R1 resistive, cos phi = 1 3 A 250 V AC || relay output R1 resistive, cos phi = 1 3 A 30 V DC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R1 inductive, cos phi = 0.4 7 ms 2 A 30 V DC || relay output R2, R3 resistive, cos phi = 1 5 A 250 V AC || relay output R2, R3 resistive, cos phi = 1 5 A 30 V DC || relay output R2, R3 inductive, cos phi = 0.4 7 ms 2 A 250 V AC || relay output R2, R3 inductive, cos phi = 0.4 7 ms 2 A 30 V DC |
Physical Interface | Ethernet || 2-wire RS 485 |
Minimum Switching Current | relay output R1, R2, R3 5 mA 24 V DC |
Refresh Time | relay output R1, R2, R3)5 ms +/- 0.5 ms) |
Isolation | between power and control terminals |
With Safety Function Safe Programmable Logic | false |
Brake Chopper Integrated | true |
Quantity Per Set | 1 |
Type Of Polarization | no impedance Modbus serial |
Braking To Standstill | by DC injection |
Discrete Input Type | DI1...DI8 programmable, 24 V DC <= 30 V)3.5 kOhm || DI7, DI8 programmable as pulse input 0-30 kHz, 24 V DC <= 30 V) || STOA, STOB safe torque off, 24 V DC <= 30 V)> 2.2 kOhm |
4 Quadrant Operation Possible | true |
Protection Type | thermal protection motor || safe torque off motor || motor phase break motor || thermal protection drive || safe torque off drive || overheating drive || overcurrent between output phases and earth drive || overload of output voltage drive || short-circuit protection drive || motor phase break drive || overvoltages on the DC bus drive || line supply overvoltage drive || line supply undervoltage drive || line supply phase loss drive || overspeed drive || break on the control circuit drive |
Supply | external supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection || internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection || internal supply for digital inputs and STO 24 V DC 21-27 V), <200 mA overload and short-circuit protection |
With Safety Function Safely Limited Speed (Sls) | true |
Exchange Mode | half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP |
Local Signalling | local diagnostic 3 LED mono/dual colour) || embedded communication status 5 LED dual colour) || communication module status 2 LED dual colour) || presence of voltage 1 LED red) |
Data Format | 8 bits, configurable odd, even or no parity Modbus serial |
Offer Sustainability | |
Mercury Free | Yes |
Circularity Profile | ENVEOLI1404008EN |
Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
Weee | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
China Rohs Regulation | X |
Upgradeability | Upgraded components available |
Rohs Exemption Information | Yes |
Environmental Disclosure | ENVPEP1404008EN |
Sustainable Offer Status | Green Premium product |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Environment | |
Product Certifications | UL || CSA || TÜV |
Permitted Relative Humidity (During Operation) | class 3K5 according to EN 60721-3 |
Operating Altitude | <= 3280.84 ft (1000 m) without derating || 1000...4800 m with current derating 1 % per 100 m |
Overvoltage Category | III |
Environmental Class (During Operation) | class 3C3 according to IEC 60721-3-3 || class 3S3 according to IEC 60721-3-3 |
Maximum Acceleration Under Shock Impact (During Operation) | 150 m/s² at 11 ms |
Pollution Degree | 2 |
Electromagnetic Compatibility | electrostatic discharge immunity test level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test level 4 IEC 61000-4-4 || 1.2/50 µs - 8/20 µs surge immunity test level 3 IEC 61000-4-5 || conducted radio-frequency immunity test level 3 IEC 61000-4-6 |
Ambient Air Temperature For Operation | -15-50 °C without derating) || 50-60 °C with derating factor) |
Volume Of Cooling Air | 103 m3/h |
Marking | CE |
Maximum Deflection Under Vibratory Load (During Operation) | 1.5 mm at 2...13 Hz |
Maximum Acceleration Under Vibrational Stress (During Operation) | 10 m/s² at 13...200 Hz |
Noise Level | 59.5 dB |
Ambient Air Temperature For Storage | -40-70 °C |
Relative Humidity | 5-95 % without condensation IEC 60068-2-3 |
Assembly Style | enclosed |
Operating Position | vertical +/- 10 degree |
Maximum Thdi | <48 % from 80...100 % of load IEC 61000-3-12 |
Ambient Air Transport Temperature | -40-70 °C |
Standards | UL 508C || EN/IEC 61800-3 || EN/IEC 61800-5-1 || IEC 61000-3-12 || IEC 60721-3 || IEC 61508 || IEC 13849-1 |
Insulation Resistance | > 1 MOhm 500 V DC for 1 minute to earth |
Shock Resistance | 15 gn 11 ms IEC 60068-2-27 |
Environmental Characteristic | chemical pollution resistance class 3C3 EN/IEC 60721-3-3 || dust pollution resistance class 3S3 EN/IEC 60721-3-3 |
Vibration Resistance | 1.5 mm peak to peak 2-13 Hz)IEC 60068-2-6 || 1 gn 13-200 Hz)IEC 60068-2-6 |
Noise Level | 59.5 dB 86/188/EEC |
Regulation Loop | adjustable PID regulator |