BCPM - Modbus to BACnet protocol converter
- Manufactured by:
- Schneider Electric
The E8951 Modbus-to-BACnet protocol converter enables integration of a broad selection of meters, like the PowerLogic BCPM. Supports BACnet IP and Modbus TCP access simultaneously. Compatible with following setup Modbus RTU downstream, BACnet IP, Modbus TCP, SNMP upstream ethernet, BACnet MS/TP or Modbus RTU upstream serial. Specification of the downstream interface 2-wire RS-485 Modbus RTU, can support up to 32 devices. Specification of the upstream ethernet interface 10/100 MB for BACnet IP, Modbus TCP and SNMP protocols. Specification of the upstream serial interface 2-wire RS-485 BACnet MS/TP or Modbus RTU protocols. The gateway need to be supplied with 9 to 30 V DC, or 12 to 24 V AC 50 or 60 Hz. Dimensions of the device are 92 mm in width, 115 mm in heigt and 41 mm in depth. Approved by the following agency CE; TUV approved to UL916; FCC Parc 15 Class A and BTL.
Specifications
Certifications | CE |
---|---|
Current | 12 V |
Depth | 41 mm |
Height | 129 mm |
Number of Outputs | 0 |
Standard | UL 916 |
Width | 74 mm |
Specifications | |
Product Or Component Type | protocol converter |
Range | PowerLogic |
Communication Gateway | Modbus to BACnet |
Device Application | gateway |
Device Short Name | E8951 |
Complementary | |
Height | 129 mm |
Range Compatibility | PowerLogic |
Width | 74 mm |
Depth | 41 mm |
Number Of Outputs | 0 |
Communication Port Protocol | downside Modbus RTU 2-wire RS485 - screw terminal block || upside Modbus TCP ETHERNET - RJ45 || upside BACnet IP ETHERNET - RJ45 || upside BACnet MS/TP 2-wire RS485 - screw terminal block |
Maximum Number Of Supported Devices | 32 Modbus RTU maximum 10000 BACnet data objects |
Number Of Inputs | 0-0 |
Current Consumption | 240 mA 12 V |
Fixing Mode | by clips 35 mm DIN rail) || by screws wall) |
[Us] Rated Supply Voltage | 9...30 V DC || 12...24 V AC |
Transmission Rate | 9.6...38.4 kbauds Modbus RTU downside || 10/100 Mbit/s Modbus TCP upside || 10/100 Mbit/s BACnet IP upside || 9.6, 19.2, 38.4, 76.8 kbauds BACnet MS/TP upside |
Offer Sustainability | |
Rohs Exemption Information | Yes |
Mercury Free | Yes |
Toxic Heavy Metal Free | Yes |
Reach Regulation | Free of Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Reach Free Of Svhc | Yes |
Weee | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
China Rohs Regulation | X |
Eu Rohs Directive | Compliant |
Environment | |
Product Certifications | CE || TÜV |
Ambient Air Temperature For Operation | -40-122 °C |
Standards | UL 916 |
Relative Humidity | 5-90 % without condensation |