Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 50kA, thermal magnetic multifunction, Everlink terminals

Manufactured by:
Schneider Electric
Schneider electric

Da55e1479e438886cfeb39f9d3add1205005e42c medium
Price (VAT excluded)
€ 335.70
Nuova Elva code
GV4PEM07N
Manufacturer code
GV4PEM07N
Availability
Send request for quotation

TeSys GV motor circuit breaker, 3 poles (3P), 7A/690V, for protection of 3-phase motors 1.5-3kW@400V. Multifunction circuit breaker, it provides thermal magnetic protection and advanced motor protection, breaking capacity Icu 50kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 2.9-7A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Advanced protections are adjustable with a smartphone using wireless NFC and include short time delay protection Isd with a setting range 5-13 Ir, phase unbalance and loss protection, ground fault protection, locked rotor (jam), long start. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). It can be equiped externally with 1 or 2 auxiliary SDx modules in order to have alarming and fault differentiation. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).

Specifications

CertificationsATEX
ColorGray
Depth116 mm
Height155 mm
Line Rated Current7 A
Net Weight1.45 kg
StandardCSA C22.2 No 60947-4-1
Storage Temperature-50-85 °C
Trip Point119-119 A
Warranty Length18 months
Width81 mm

Specifications

Range Of ProductTeSys GV4
Product Or Component Typemotor circuit breaker
Product NameTeSys GV4 || TeSys Deca
RangeTeSys Deca
Device Applicationmotor protection
Device Short NameGV4PEM
Trip Unit Technologyelectronic || thermal-magnetic

Contractual warranty

Warranty18 months

Complementary

Mechanical Robustnessvibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6 || vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6 || shocks 15 gn 11 ms IEC 60068-2-27
Maximum Operating Rate25 cyc/h
Operating Positionany position
Connections - TerminalsEverLink BTR screw connectors top) 1 1.5-70 mm² - solid || EverLink BTR screw connectors top) 1 1.5-50 mm² - flexible || EverLink BTR screw connectors bottom) 1 2.5-95 mm² - solid || EverLink BTR screw connectors bottom) 1 2.5-70 mm² - flexible
Utilisation Categorycategory A IEC 60947-2 || AC-3 IEC 60947-4-1
Net Weight1.45 kg
[Uimp] Rated Impulse Withstand Voltage8 kV IEC 60947-2
Control Typetoggle
Power Dissipation Per Pole4.6 W
Electrical Durability40000 cycles AC-3 440 V In/2 || 40000 cycles AC-3 440 V In
Breaking Capacity100 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2 || 50 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 15 kA Icu 525 V AC 50/60 Hz IEC 60947-2 || 65 kA 208Y/120 V AC 50/60 Hz UL 60947 || 65 kA 240 V AC 50/60 Hz UL 60947 || 35 kA 480Y/277 V AC 50/60 Hz UL 60947 || 8 kA Icu 660...690 V AC 50/60 Hz IEC 60947-2 || 25 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 18 kA 600Y/347 V AC 50/60 Hz UL 60947
Line Rated Current7 A
Suitability For Isolationyes IEC 60947-1
[Ui] Rated Insulation Voltage800 V AC 50/60 Hz IEC 60947-2
Tightening Torque9 N.m 16-95 mm² || 5 N.m 1.5-10 mm²
Mechanical Durability40000 cycles
Poles Description3P
ColorGray RAL 7016)
Width81 mm
Depth116 mm
[Ue] Rated Operational Voltage690 V AC 50/60 Hz IEC 60947-2
Height155 mm
Phase Failure Sensitivityyes IEC 60947-4-1
Rated Dutycontinuous IEC 60947-4-1
Magnetic Tripping Current119-119 A
[Ith] Conventional Free Air Thermal Current115 A IEC 60947-4-1
Motor Power Kw1.5-1.5 kW 400...415 V AC 50/60 Hz || 2.2-2.2 kW 400...415 V AC 50/60 Hz || 2.5-2.5 kW 400...415 V AC 50/60 Hz || 3-3 kW 400...415 V AC 50/60 Hz || 2.2-2.2 kW 500 V AC 50/60 Hz || 2.5-2.5 kW 500 V AC 50/60 Hz || 3-3 kW 500 V AC 50/60 Hz || 4-4 kW 500 V AC 50/60 Hz || 3-3 kW 660...690 V AC 50/60 Hz || 4-4 kW 660...690 V AC 50/60 Hz || 5.5-5.5 kW 660...690 V AC 50/60 Hz || 7.5-7.5 kW 660...690 V AC 50/60 Hz

Offer Sustainability

Rohs Exemption InformationYes
Eu Rohs DirectiveCompliant
Halogen Content PerformanceHalogen free plastic parts product
Mercury FreeYes
Environmental DisclosureENVPEP1704004EN
Sustainable Offer StatusGreen Premium product
Pvc FreeYes
Reach RegulationReference contains Substances of Very High Concern above the threshold
WeeeThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs RegulationProduct out of China RoHS scope. Substance declaration for your information.
Circularity ProfileENVEOLI1704004EN

Environment

Product CertificationsIEC || UL || CSA || CCC || EAC || ATEX || EU-RO MR
Fire Resistance960 °C IEC 60695-2-11
Ik Degree Of ProtectionIK07 IEC 62262
Ambient Air Temperature For Operation-25-70 °C
StandardsCSA C22.2 No 60947-4-1 || UL 60947-4-1 || EN/IEC 60947-4-1 || EN/IEC 60947-2
Climatic WithstandIACS E10
Pollution Degree3
Ambient Air Temperature For Storage-50-85 °C
Ip Degree Of ProtectionIP40 IEC 60529
Operating Altitude5000 m

Docs


Other Schneider Electric items

Request a quote