Circle Diameter Of The Mounting Holes | 66.6 mm |
---|
Centring Collar Depth | 1.6 mm |
---|
Discrete Input Current | 10-10 mA at 24 V safety input || 2-2 mA at 24 V 24 V signal interface |
---|
Second Shaft | without second shaft end |
---|
Marking | CE |
---|
Shaft Length | 20 mm |
---|
Net Weight | 1.4 kg |
---|
Voltage State 0 Guaranteed | -3...4.5 V |
---|
Centring Collar Diameter | 50 mm |
---|
Motor Flange Size | 57 mm |
---|
Peak Stall Torque | 0.45 N.m |
---|
Current Consumption | 11000 mA peak || 7500 mA maximum continuous |
---|
Number Of Mounting Holes | 4 |
---|
Shaft Diameter | 9 mm |
---|
Discrete Output Voltage | 23...25 V |
---|
Supply Voltage Limits | 18-55.2 V |
---|
Mounting Holes Diameter | 5.2 mm |
---|
Speed Feedback Resolution | 16384 points/turn x 4096 turns |
---|
Type Of Cooling | natural convection |
---|
Service Life In Hours | 20000 h bearing |
---|
Shaft End | untapped |
---|
Feedback Type | multi turn encoder |
---|
Commissioning Interface | RS485 Modbus TCP 9.6, 19.2 and 38.4 kbauds) |
---|
Protection Type | overload of output voltage || safe torque off || short circuit of the output voltage |
---|
Transmission Rate | 10, 100 Mbits |
---|
Accuracy Error | +/- 0.05 ° |
---|
Input/Output Type | 4 signals (each be used as input or output) |
---|
Maximum Axial Force Fa | 104 N force pressure) || 104 N tensile force) |
---|
Associated Fuse Rating | 16 A |
---|
Voltage State 1 Guaranteed | 15...30 V |
---|
Maximum Switching Current | 100 mA per output || 200 mA total |
---|
Maximum Radial Force Fr | 89 N |
---|
Mounting Support | flange |
---|
Number Of Motor Stacks | 1 |
---|
Rotor Inertia | 0.095 kg.cm² |
---|
Continuous Stall Torque | 0.31 N.m |
---|
Product Certifications | TÜV || UL || cUL |
---|
Operating Altitude | <= 3280.84 ft (1000 m) without derating |
---|
Standards | EN/IEC 50178 || IEC 61800-3, Ed 2 || IEC 60072-1 || EN/IEC 61800-3 || EN 50347 || EN 61800-3 : 2001-02 || EN 61800-3:2001, second environment |
---|
Ambient Air Temperature For Operation | 40-55 °C with power derating of 2 % per °C) || 0-40 °C without derating) |
---|
Shock Resistance | 150 m/s² 1000 shocks EN/IEC 60068-2-29 |
---|
Vibration Resistance | 20 m/s² 10-500 Hz) 10 cycles EN/IEC 60068-2-6 |
---|
Permissible Ambient Air Temperature Around The Device | 105 °C power amplifier || 110 °C motor |
---|
Ambient Air Temperature For Storage | -25-70 °C |
---|
Relative Humidity | 15-85 % without condensation |
---|
Ip Degree Of Protection | shaft bushing IP41 EN/IEC 60034-5 || total except shaft bushing IP54 EN/IEC 60034-5 |
---|