TeSys D time delay auxiliary contact block, for contactors LC1D, LC1F and control relays CAD. It provides 1NO+1NC contacts rated up to 10A 690V AC, Off-delay setting range 1-30s, connection by screw clamp terminals. A delay of 40ms is ensured between opening of NC contact and closing of NO contact. Clip-on front mounting, it procures high reliability and durability. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHs/Reach).
Specifications
Certifications | CCC |
---|---|
Color | Gray |
Contact Configuration | 1 NO + 1 NC |
Depth | 61 mm |
Height | 48 mm |
Standard | CSA C22.2 No 60947-5-1 |
Storage Temperature | -60-80 °C |
Warranty Length | 18 months |
Width | 44 mm |
Specifications | |
Product Certifications | IECEE CB Scheme || UL || CSA || CCC || EAC || UKCA |
Mounting Location | front |
Pole Contact Composition | 1 NO + 1 NC |
[Ui] Rated Insulation Voltage | 690 V IEC 60947-5-1 || 600 V UL 60947-5-1 || 600 V CSA C22.2 No 60947-5-1 |
[Ie] Rated Operational Current | 6 A120 V AC-15 || 1.04 A690 V AC-15 || 0.55 A125 V DC-13 || 0.1 A600 V DC-13 |
Time Delay Range | 1...30 s |
Auxiliary Contacts Operation | time delay |
Device Application | star delta starter |
[Ith] Conventional Free Air Thermal Current | 10 A 60 °C |
Standards | CSA C22.2 No 60947-5-1 || GB/T 14048.5 || EN/IEC 60947-5-1 |
Timer Type | on delay |
[Ue] Rated Operational Voltage | 690 V AC 25...400 Hz |
Range Compatibility | TeSys D CAD || TeSys D LC1D || TeSys F LC1F || TeSys F CR1F || TeSys Deca CAD || TeSys Deca LC1D |
Product Or Component Type | time delay auxiliary contact block |
Product Name | TeSys Deca |
Range | TeSys || TeSys Deca |
Contractual warranty | |
Warranty | 18 months |
Complementary | |
Non-Overlap Time | 1.5 ms on de-energisation no overlap between NC and NO contact || 1.5 ms on energisation no overlap between NC and NO contact |
Tightening Torque | 1.7 N.m flat Ø 6 mm || 1.7 N.m Philips No 2 || 1.7 N.m pozidriv No 2 |
Mechanical Durability | 5 Mcycles |
Color | dark grey |
Width | 44 mm |
Depth | 61 mm |
Permissible Short-Time Rating | 100 A 60 °C 1 s || 120 A 60 °C 500 ms || 140 A 60 °C 100 ms |
Minimum Switching Current | 5 mA |
Height | 48 mm |
Protection Type | gG fuse 10 A |
Insulation Resistance | > 10 MOhm |
Irms Rated Making Capacity | 140 A <= 690 V AC IEC 60947-5-1 || 250 A <= 690 V DC IEC 60947-5-1 |
Connections - Terminals | screw clamp terminals 1 1-2.5 mm²flexible with cable end || screw clamp terminals 1 1-2.5 mm²flexible without cable end || screw clamp terminals 2 1-2.5 mm²flexible with cable end || screw clamp terminals 2 1-2.5 mm²flexible without cable end || screw clamp terminals 1 1-2.5 mm²rigid || screw clamp terminals 2 1-2.5 mm²rigid || screw clamp terminals |
Minimum Switching Voltage | 17 V |
Offer Sustainability | |
Rohs Exemption Information | Yes |
China Rohs Regulation | Product out of China RoHS scope. Substance declaration for your information. |
Eu Rohs Directive | Compliant |
Mercury Free | Yes |
Environmental Disclosure | ENVPEP110702 |
Sustainable Offer Status | Green Premium product |
Pvc Free | Yes |
Reach Regulation | Free of Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: Cancer - www.P65Warnings.ca.gov |
Reach Free Of Svhc | Yes |
Weee | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
Environment | |
Ambient Air Temperature For Operation | -40-70 °C |
Ip Degree Of Protection | IP20 conforming to IEC 60529 |
Ambient Air Temperature For Storage | -60-80 °C |
Environmental Characteristic | normal environment |
Protective Treatment | TH IEC 60068 |
Operating Altitude | 9842.52 ft (3000 m) |