IEC contactor, TeSys Deca, nonreversing, 200A resistive, 4 pole, 4 NO, 110VAC 50/60Hz coil, open style
- Manufactured by:
- Schneider Electric
- Price (VAT excluded)
- € 768.60
- Nuova Elva code
- LC1D115004F7
- Manufacturer code
- LC1D115004F7
- Availability
- Standard lead time: 10 days
TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 200A resistive load rating. Contactor is supplied with a 110 VAC 50/60 Hz coil. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 6.22 inches tall, 5.91 inches wide and 5.20 inches deep. It weighs 6.31 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.
Specifications
Certifications | BV |
---|---|
Contact Configuration | 4 NO |
Depth | 132 mm |
Height | 158 mm |
Impedance | 0.6 MOhm - Ith 200 A 50 Hz Power Circuit |
Net Weight | 2.86 kg |
Standard | CSA C22.2 No 14 |
Warranty Length | 18 months |
Width | 150 mm |
Specifications | |
[Uc] Control Circuit Voltage | 110 V AC 50/60 Hz |
Device Short Name | LC1D |
[Ue] Rated Operational Voltage | power circuit <= 1000 V AC 25...400 Hz || power circuit <= 460 V DC |
Range Of Product | TeSys Deca |
Contactor Application | resistive load |
Product Or Component Type | contactor |
Range | TeSys |
Utilisation Category | AC-1 || AC-3 || AC-3e || AC-4 |
[Ie] Rated Operational Current | 200 A 60 °C) <= 440 V AC AC-1 power circuit |
Poles Description | 4P |
Contractual warranty | |
Warranty | 18 months |
Complementary | |
Power Dissipation Per Pole | 24 W AC-1 |
Rated Breaking Capacity | 1100 A 440 V power circuit IEC 60947 |
Irms Rated Making Capacity | 1260 A 440 V power circuit IEC 60947 |
Associated Fuse Rating | 250 A gG <= 690 V type 1 power circuit || 200 A gG <= 690 V type 2 power circuit |
[Uimp] Rated Impulse Withstand Voltage | 8 kV IEC 60947 |
Inrush Power In Va | 280-350 VA 60 Hz 0.8 20 °C) || 280-350 VA 50 Hz 0.8 20 °C) |
Pole Contact Composition | 4 NO |
Connections - Terminals | control circuit screw clamp terminals 2 1-2.5 mm² flexible with cable end || control circuit screw clamp terminals 1 1-2.5 mm² flexible with cable end || control circuit screw clamp terminals 1 1-2.5 mm² flexible without cable end || control circuit screw clamp terminals 2 1-2.5 mm² flexible without cable end || control circuit screw clamp terminals 1 1-2.5 mm² solid without cable end || control circuit screw clamp terminals 2 1-2.5 mm² solid without cable end || power circuit connector 1 10-120 mm² flexible without cable end || power circuit connector 2 10-50 mm² flexible without cable end || power circuit connector 1 10-120 mm² flexible with cable end || power circuit connector 2 10-50 mm² flexible with cable end || power circuit connector 1 10-120 mm² solid without cable end || power circuit connector 2 10-50 mm² solid without cable end |
Coil Technology | built-in bidirectional peak limiting diode suppressor |
Operating Time | 6...20 ms opening || 20...50 ms closing |
Maximum Operating Rate | 2400 cyc/h 60 °C |
Average Impedance | 0.6 mOhm - Ith 200 A 50 Hz power circuit |
Tightening Torque | control circuit 1.2 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.2 N.m screw clamp terminals Philips No 2 || power circuit 12 N.m connector hexagonal 4 mm || control circuit 1.2 N.m screw clamp terminals pozidriv No 2 |
Electrical Durability | 0.8 Mcycles 200 A AC-1 <= 440 V |
Mechanical Durability | 8 Mcycles |
Compatibility Code | LC1D |
Hold-In Power Consumption In Va | 2-18 VA 60 Hz 0.3 20 °C) || 2-18 VA 50 Hz 0.3 20 °C) |
Overvoltage Category | III |
[Ui] Rated Insulation Voltage | power circuit 600 V CSA || power circuit 600 V UL || power circuit 1000 V IEC 60947-4-1 |
[Icw] Rated Short-Time Withstand Current | 250 A 40 °C - 10 min power circuit || 550 A 40 °C - 1 min power circuit || 950 A 40 °C - 10 s power circuit || 1100 A 40 °C - 1 s power circuit |
Heat Dissipation | 3-8 W 50/60 Hz |
Protective Cover | with |
[Ith] Conventional Free Air Thermal Current | 200 A 60 °C power circuit |
Control Circuit Voltage Limits | 0.3...0.5 Uc -40-70 °C drop-out AC 50/60 Hz || 0.8...1.15 Uc -40-55 °C operational AC 50/60 Hz || 1...1.15 Uc 55-70 °C operational AC 50/60 Hz |
Mounting Support | plate || rail |
Contact Compatibility | M14 |
Control Circuit Type | AC 50/60 Hz |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Pollution Degree | 3 |
Offer Sustainability | |
Rohs Exemption Information | Yes |
Circularity Profile | ENVEOLI100405 |
Eu Rohs Directive | Compliant |
Mercury Free | Yes |
Environmental Disclosure | ENVPEP060301EN |
Sustainable Offer Status | Green Premium product |
Pvc Free | Yes |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov |
Weee | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
China Rohs Regulation | Product out of China RoHS scope. Substance declaration for your information. |
Environment | |
Product Certifications | UL || BV || GL || CCC || LROS (Lloyds register of shipping) || DNV || CSA || GOST || RINA || UKCA |
Operating Altitude | 0...9842.52 ft (0...3000 m) |
Fire Resistance | 850 °C IEC 60695-2-1 |
Width | 150 mm |
Depth | 132 mm |
Permissible Ambient Air Temperature Around The Device | -40-60 °C || 60-70 °C with derating |
Height | 158 mm |
Standards | CSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508 |
Climatic Withstand | IACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat |
Net Weight | 2.86 kg |
Flame Retardance | V1 conforming to UL 94 |
Protective Treatment | THIEC 60068-2-30 |
Ip Degree Of Protection | IP20 front face IEC 60529 |
Mechanical Robustness | vibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 6 Gn for 11 ms) |