IEC contactor, TeSys Deca, nonreversing, 200A resistive, 4 pole, 4 NO, 110VAC 50/60Hz coil, open style

Manufactured by:
Schneider Electric
Schneider electric

0b56824657ff26301403b2dd35be96e40081fc60 medium
Price (VAT excluded)
€ 768.60
Nuova Elva code
LC1D115004F7
Manufacturer code
LC1D115004F7
Availability
Standard lead time: 10 days

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 4 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactor has four normally open power contacts. Power contacts have a 200A resistive load rating. Contactor is supplied with a 110 VAC 50/60 Hz coil. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 6.22 inches tall, 5.91 inches wide and 5.20 inches deep. It weighs 6.31 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.

Specifications

CertificationsBV
Contact Configuration4 NO
Depth132 mm
Height158 mm
Impedance0.6 MOhm - Ith 200 A 50 Hz Power Circuit
Net Weight2.86 kg
StandardCSA C22.2 No 14
Warranty Length18 months
Width150 mm

Specifications

[Uc] Control Circuit Voltage110 V AC 50/60 Hz
Device Short NameLC1D
[Ue] Rated Operational Voltagepower circuit <= 1000 V AC 25...400 Hz || power circuit <= 460 V DC
Range Of ProductTeSys Deca
Contactor Applicationresistive load
Product Or Component Typecontactor
RangeTeSys
Utilisation CategoryAC-1 || AC-3 || AC-3e || AC-4
[Ie] Rated Operational Current200 A 60 °C) <= 440 V AC AC-1 power circuit
Poles Description4P

Contractual warranty

Warranty18 months

Complementary

Power Dissipation Per Pole24 W AC-1
Rated Breaking Capacity1100 A 440 V power circuit IEC 60947
Irms Rated Making Capacity1260 A 440 V power circuit IEC 60947
Associated Fuse Rating250 A gG <= 690 V type 1 power circuit || 200 A gG <= 690 V type 2 power circuit
[Uimp] Rated Impulse Withstand Voltage8 kV IEC 60947
Inrush Power In Va280-350 VA 60 Hz 0.8 20 °C) || 280-350 VA 50 Hz 0.8 20 °C)
Pole Contact Composition4 NO
Connections - Terminalscontrol circuit screw clamp terminals 2 1-2.5 mm² flexible with cable end || control circuit screw clamp terminals 1 1-2.5 mm² flexible with cable end || control circuit screw clamp terminals 1 1-2.5 mm² flexible without cable end || control circuit screw clamp terminals 2 1-2.5 mm² flexible without cable end || control circuit screw clamp terminals 1 1-2.5 mm² solid without cable end || control circuit screw clamp terminals 2 1-2.5 mm² solid without cable end || power circuit connector 1 10-120 mm² flexible without cable end || power circuit connector 2 10-50 mm² flexible without cable end || power circuit connector 1 10-120 mm² flexible with cable end || power circuit connector 2 10-50 mm² flexible with cable end || power circuit connector 1 10-120 mm² solid without cable end || power circuit connector 2 10-50 mm² solid without cable end
Coil Technologybuilt-in bidirectional peak limiting diode suppressor
Operating Time6...20 ms opening || 20...50 ms closing
Maximum Operating Rate2400 cyc/h 60 °C
Average Impedance0.6 mOhm - Ith 200 A 50 Hz power circuit
Tightening Torquecontrol circuit 1.2 N.m screw clamp terminals flat Ø 6 mm || control circuit 1.2 N.m screw clamp terminals Philips No 2 || power circuit 12 N.m connector hexagonal 4 mm || control circuit 1.2 N.m screw clamp terminals pozidriv No 2
Electrical Durability0.8 Mcycles 200 A AC-1 <= 440 V
Mechanical Durability8 Mcycles
Compatibility CodeLC1D
Hold-In Power Consumption In Va2-18 VA 60 Hz 0.3 20 °C) || 2-18 VA 50 Hz 0.3 20 °C)
Overvoltage CategoryIII
[Ui] Rated Insulation Voltagepower circuit 600 V CSA || power circuit 600 V UL || power circuit 1000 V IEC 60947-4-1
[Icw] Rated Short-Time Withstand Current250 A 40 °C - 10 min power circuit || 550 A 40 °C - 1 min power circuit || 950 A 40 °C - 10 s power circuit || 1100 A 40 °C - 1 s power circuit
Heat Dissipation3-8 W 50/60 Hz
Protective Coverwith
[Ith] Conventional Free Air Thermal Current200 A 60 °C power circuit
Control Circuit Voltage Limits0.3...0.5 Uc -40-70 °C drop-out AC 50/60 Hz || 0.8...1.15 Uc -40-55 °C operational AC 50/60 Hz || 1...1.15 Uc 55-70 °C operational AC 50/60 Hz
Mounting Supportplate || rail
Contact CompatibilityM14
Control Circuit TypeAC 50/60 Hz
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Pollution Degree3

Offer Sustainability

Rohs Exemption InformationYes
Circularity ProfileENVEOLI100405
Eu Rohs DirectiveCompliant
Mercury FreeYes
Environmental DisclosureENVPEP060301EN
Sustainable Offer StatusGreen Premium product
Pvc FreeYes
Reach RegulationReference contains Substances of Very High Concern above the threshold
California Proposition 65WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
WeeeThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs RegulationProduct out of China RoHS scope. Substance declaration for your information.

Environment

Product CertificationsUL || BV || GL || CCC || LROS (Lloyds register of shipping) || DNV || CSA || GOST || RINA || UKCA
Operating Altitude0...9842.52 ft (0...3000 m)
Fire Resistance850 °C IEC 60695-2-1
Width150 mm
Depth132 mm
Permissible Ambient Air Temperature Around The Device-40-60 °C || 60-70 °C with derating
Height158 mm
StandardsCSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || IEC 60947-4-1 || IEC 60947-5-1 || UL 508
Climatic WithstandIACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Net Weight2.86 kg
Flame RetardanceV1 conforming to UL 94
Protective TreatmentTHIEC 60068-2-30
Ip Degree Of ProtectionIP20 front face IEC 60529
Mechanical Robustnessvibrations contactor open 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor closed 15 Gn for 11 ms) || shocks contactor open 6 Gn for 11 ms)

Docs


Frequently bought together


Other Schneider Electric items

Request a quote