IEC contactor, TeSys D, nonreversing, 50A, 40HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 24VAC 50/60Hz coil, open

Manufactured by:
Schneider Electric
Schneider electric

F014f0c3443367591a22c6543f4dd6c0eecd84c7 medium
Price (VAT excluded)
€ 221.85
Nuova Elva code
LC1D50B7
Manufacturer code
LC1D50B7
Availability
Send request for quotation

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 50A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 15HP at 200 to 208VAC, 15HP at 240VAC, 40HP at 480VAC and 40HP at 600VAC three phase. Contactor is also rated for 3HP at 115VAC and 7.5HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 110A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 24 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.87 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.

Specifications

CertificationsBV
Contact Configuration1 NO + 1 NC
Depth120 mm
Height122 mm
Net Weight1.4 kg
StandardEN 60947-5-1
Warranty Length18 months
Width55 mm

Specifications

[Uc] Control Circuit Voltage120 V AC 50/60 Hz
Device Short NameLC1D
[Ue] Rated Operational Voltagepower circuit <= 690 V AC 25...400 Hz
Range Of ProductTeSys Deca
Contactor Applicationresistive load
Product Or Component Typecontactor
RangeTeSys
Utilisation CategoryAC-1 || AC-2 || AC-3e
[Ie] Rated Operational Current50 A 60 °C) <= 440 V AC AC-3e power circuit || 80 A 60 °C) <= 440 V AC AC-1 power circuit || 65 A 60 °C) <= 440 V AC AC-3 power circuit
Poles Description3P

Contractual warranty

Warranty18 months

Complementary

Non-Overlap Time1.5 ms on de-energisation between NC and NO contacts || 1.5 ms on energisation between NC and NO contacts
Insulation Resistance> 10 MOhm control circuit
Rated Breaking Capacity1000 A 440 V power circuit IEC 60947
Irms Rated Making Capacity1000 A 440 V power circuit IEC 60947 || 140 A AC control circuit IEC 60947-5-1
Associated Fuse Rating100 A gG <= 690 V type 2 power circuit || 10 A gG control circuit IEC 60947-5-1 || 125 A gG <= 690 V type 1 power circuit
[Uimp] Rated Impulse Withstand Voltage6 kV IEC 60947
Inrush Power In Va140-140 VA 0.75 20 °C) || 160-160 VA 0.75 20 °C)
Pole Contact Composition3 NO
Connections - Terminalscontrol circuit screw clamp terminals 1 1-4 mm² flexible without cable end || control circuit screw clamp terminals 2 1-4 mm² flexible without cable end || control circuit screw clamp terminals 1 1-2.5 mm² flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm² flexible with cable end || power circuit screw terminals 1 2.5-25 mm² rigid || power circuit screw terminals 2 2.5-16 mm² rigid || power circuit screw terminals 1 2.5-25 mm² flexible without cable end || power circuit screw terminals 2 2.5-16 mm² flexible without cable end || power circuit screw terminals 1 2.5-25 mm² flexible with cable end || power circuit screw terminals 2 2.5-10 mm² flexible with cable end || control circuit screw clamp terminals 1 1-4 mm² rigid || control circuit screw clamp terminals 2 1-4 mm² rigid
Coil Technologywithout built-in bidirectional peak limiting diode suppressor
Operating Time4...19 ms opening || 12...26 ms closing
Minimum Switching Current5 mA control circuit
Minimum Switching Voltage17 V control circuit
Maximum Operating Rate3600 cyc/h 60 °C
Tightening Torquepower circuit 5 N.m screw terminal flat Ø 6 to Ø 8 mm || control circuit 1.7 N.m screw clamp terminal pozidriv No 2 || control circuit 1.7 N.m screw clamp terminal flat Ø 6 mm || control circuit 1.7 N.m screw clamp terminal Philips No 2
Mechanical Durability6000000 cycles
Auxiliary Contacts Typemechanically linked 1 NO + 1 NC IEC 60947-5-1 || mirror contact 1 NC IEC 60947-4-1
Compatibility CodeLC1D
Hold-In Power Consumption In Va13-13 VA 60 Hz 0.3 20 °C) || 15-15 VA 50 Hz 0.3 20 °C)
Overvoltage CategoryIII
Maximum Horse Power Rating15 hp 200/208 V at AC 60 Hz for 3 phase || 15 hp 230/240 V at AC 60 Hz for 3 phase || 40 hp 460/480 V at AC 60 Hz for 3 phase || 40 hp 575/600 V at AC 60 Hz for 3 phase || 5 hp 115 V at AC 60 Hz for 1 phase || 10 hp 230/240 V at AC 60 Hz for 1 phase
Motor Power Kw30 kW 440 V AC 50 Hz AC-3) || 30 kW 500 V AC 50 Hz AC-3) || 33 kW 660...690 V AC 50 Hz AC-3) || 15 kW 220...230 V AC 50 Hz AC-3) || 11 kW 400 V AC 50 Hz AC-4) || 30 kW 1000 V AC 50 Hz AC-3) || 22 kW 380...400 V AC 50 Hz AC-3e) || 25 kW 415 V AC 50 Hz AC-3e) || 30 kW 440 V AC 50 Hz AC-3e) || 30 kW 500 V AC 50 Hz AC-3e) || 33 kW 660...690 V AC 50 Hz AC-3e) || 15 kW 220...230 V AC 50 Hz AC-3e) || 30 kW 1000 V AC 50 Hz AC-3e) || 30 kW 380...400 V AC 50 Hz AC-3)
Power Dissipation Per Pole3.7 W AC-3e || 9.6 W AC-1 || 6.3 W AC-3
[Ui] Rated Insulation Voltagepower circuit 600 V CSA || power circuit 600 V UL || control circuit 690 V IEC 60947-1 || power circuit 690 V IEC 60947-1 || control circuit 600 V CSA || control circuit 600 V UL
Heat Dissipation4-5 W 50/60 Hz control circuit
Protective Coverwith
Auxiliary Contact Composition1 NO + 1 NC
[Ith] Conventional Free Air Thermal Current10 A 60 °C control circuit || 80 A 60 °C power circuit
Control Circuit Voltage Limits0.85...1.1 Uc -40-60 °C operational AC 60 Hz || 1...1.1 Uc 60-70 °C operational AC 50/60 Hz || 0.3...0.6 Uc -40-70 °C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60 °C operational AC 50 Hz
Mounting Supportrail
Control Circuit TypeAC 50/60 Hz
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1

Offer Sustainability

Rohs Exemption InformationYes
WeeeThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs RegulationPro-active China RoHS declaration (out of China RoHS legal scope)
Circularity ProfileENVEOLI1503009EN
Eu Rohs DirectiveCompliant
Mercury FreeYes
Environmental DisclosureENVPEP1503009EN
Sustainable Offer StatusGreen Premium product
Pvc FreeYes
Toxic Heavy Metal FreeYes
Reach RegulationFree of Substances of Very High Concern above the threshold
California Proposition 65WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
Reach Free Of SvhcYes

Environment

Product CertificationsGOST || GL || DNV || LROS (Lloyds register of shipping) || CCC || RINA || BV || UKCA || UL
Quantity Per Setset of 10
Fire Resistance850 °C IEC 60695-2-1
Width55 mm
Depth120 mm
Height122 mm
StandardsEN 60947-5-1 || UL 508 || IEC 60947-4-1 || IEC 60947-5-1
Climatic WithstandIACS E10 exposure to damp heat || IEC 60947-1 Annex Q category D exposure to damp heat
Net Weight1.4 kg
Flame RetardanceV1 conforming to UL 94
Ip Degree Of ProtectionIP2X IEC 60529 || IP2X VDE 0106
Mechanical Robustnessvibrations contactor opened 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor opened 10 Gn for 11 ms)
Operating Altitude0...9842.52 ft (0...3000 m)

Docs


Frequently bought together


Other Schneider Electric items

Request a quote