IEC contactor, TeSys D, nonreversing, 65A, 40HP at 480VAC, up to 100kA SCCR, 3 phase, 3 NO, 220VAC 50/60Hz coil, open

Manufactured by:
Schneider Electric
Schneider electric

D567c08e43647fff1a6ece0ba1e469a4f5202d20 medium
Nuova Elva code
LC1D65M7
Availability
Send request for quotation

TeSys D contactors have been designed for perfect integration into control systems. They can be used to create motor starters for almost any type of application. TeSys D contactors are available in 13 contactor ratings for inductive motor applications up to 150 full-load amps and resistive loads up to 200 amps. This 65A inductive 3 pole IEC contactor can be mounted on DIN rail or mounted directly to a panel. Contactors have both Horsepower and Kw motor rating for international acceptance. Contactor is rated for 20HP at 200 to 208VAC, 20HP at 240VAC, 40HP at 480VAC and 50HP at 600VAC three phase. Contactor is also rated for 5HP at 115VAC and 10HP at 240VAC single phase. When used with a 480VAC up to 110A circuit breaker, this contactor can have a SCCR up to 100kA. When used with up to a 600VAC 125A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 220 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 4.80 inches tall, 2.17 inches wide and 4.72 inches deep. It weighs 1.90 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards. Contactor also meets the requirements of RoHS/REACh making it a Green Premium product.

Specifications

CertificationsBV
Contact Configuration1 NO + 1 NC
Depth119 mm
Height127 mm
Net Weight1.4 kg
StandardCSA C22.2 No 14
Warranty Length18 months
Width75 mm

Specifications

[Uc] Control Circuit Voltage48 V AC 50/60 Hz
Device Short NameLC1D
[Ue] Rated Operational Voltagepower circuit <= 690 V AC 25...400 Hz
Range Of ProductTeSys Deca
Contactor Applicationmotor control || resistive load
Product Or Component Typecontactor
RangeTeSys
Utilisation CategoryAC-1 || AC-2 || AC-4 || AC-3e
[Ie] Rated Operational Current65 A 60 °C) <= 440 V AC AC-3 power circuit || 65 A 60 °C) <= 440 V AC AC-3e power circuit || 80 A 60 °C) <= 440 V AC AC-1 power circuit || 50 A 60 °C) <= 440 V AC AC-3 power circuit
Poles Description3P

Contractual warranty

Warranty18 months

Complementary

Non-Overlap Time1.5 ms on energisation between NC and NO contacts || 1.5 ms on de-energisation between NC and NO contacts
Safety Reliability LevelB10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 || B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1
Insulation Resistance> 10 MOhm control circuit
Rated Breaking Capacity900 A 440 V power circuit IEC 60947
Irms Rated Making Capacity140 A 440 V AC control circuit IEC 60947-5-1 || 140 A AC control circuit IEC 60947-5-1 || 900 A 440 V power circuit IEC 60947
Associated Fuse Rating125 A gG <= 690 V type 1 power circuit || 125 A gG <= 690 V type 2 power circuit IEC 60947-5-1 || 100 A gG <= 690 V type 1 power circuit || 10 A gG control circuit IEC 60947-5-1
[Uimp] Rated Impulse Withstand Voltage8 kV IEC 60947
Inrush Power In Va160-160 VA 0.75 20 °C) || 140-140 VA 0.75 20 °C)
Pole Contact Composition3 NO
Connections - Terminalscontrol circuit screw clamp terminals 2 1-4 mm² rigid without cable end || control circuit screw clamp terminals 1 1-4 mm² flexible without cable end || control circuit screw clamp terminals 2 1-4 mm² flexible without cable end || control circuit screw clamp terminals 1 1-2.5 mm² flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm² flexible with cable end || power circuit screw terminals 1 2.5-25 mm² rigid || power circuit screw terminals 2 2.5-16 mm² rigid without cable end || power circuit screw terminals 1 2.5-25 mm² flexible without cable end || power circuit screw terminals 2 2.5-16 mm² flexible without cable end || power circuit screw terminals 1 2.5-25 mm² flexible with cable end || power circuit screw terminals 2 2.5-10 mm² flexible with cable end || control circuit screw clamp terminals 2 1-4 mm² rigid || control circuit screw clamp terminals 1 1-4 mm² rigid
Coil Technologywithout built-in bidirectional peak limiting diode suppressor
Minimum Switching Current5 mA control circuit
Operating Time12...26 ms closing || 4...19 ms opening
Minimum Switching Voltage17 V control circuit
Maximum Operating Rate3600 cyc/h 60 °C
Tightening Torquecontrol circuit 1.7 N.m screw clamp terminal Philips No 2 || power circuit 5 N.m screw terminal flat Ø 6 to Ø 8 mm || control circuit 1.7 N.m screw clamp terminal pozidriv No 2 || control circuit 1.7 N.m screw clamp terminal flat Ø 6 mm
Mechanical Durability6000000 cycles
Auxiliary Contacts Typemirror contact 1 NC IEC 60947-4-1 || mechanically linked 1 NO + 1 NC IEC 60947-5-1
Compatibility CodeLC1D
Hold-In Power Consumption In Va15-15 VA 50 Hz 0.3 20 °C) || 13-13 VA 60 Hz 0.3 20 °C)
Overvoltage CategoryIII
Maximum Horse Power Rating10 hp 230/240 V at AC 60 Hz for 1 phase || 20 hp 200/208 V at AC 60 Hz for 3 phase || 20 hp 230/240 V at AC 60 Hz for 3 phase || 40 hp 460/480 V at AC 60 Hz for 3 phase || 50 hp 575/600 V at AC 60 Hz for 3 phase || 7.5 hp 230/240 V at AC 60 Hz for 1 phase || 3 hp 115 V at AC 60 Hz for 1 phase
Power Dissipation Per Pole6.4 W AC-1 || 4.2 W AC-3e || 9.6 W AC-1 || 3.7 W AC-3
Motor Power Kw30 kW 380...400 V AC 50 Hz || 37 kW 500 V AC 50 Hz || 37 kW 660...690 V AC 50 Hz || 18.5 kW 220...230 V AC 50 Hz || 30 kW 415 V AC 50 Hz || 37 kW 1000 V AC 50 Hz AC-3) || 25 kW 415 V AC 50 Hz AC-3) || 22 kW 380...400 V AC 50 Hz AC-3)
[Ui] Rated Insulation Voltagecontrol circuit 600 V UL || power circuit 600 V CSA || power circuit 600 V UL IEC 60947-1 || control circuit 690 V IEC 60947-1 || power circuit 690 V CSA IEC 60947-1 || control circuit 600 V CSA
Heat Dissipation4-5 W 50/60 Hz control circuit
Protective Coverwith
Auxiliary Contact Composition1 NO + 1 NC
Terminals Description Iso N°1(21-22)NC || (A1-A2)CO
[Ith] Conventional Free Air Thermal Current80 A 60 °C power circuit || 10 A 60 °C control circuit
Control Circuit Voltage Limits0.8...1.1 Uc -40-60 °C operational AC 50 Hz || 0.85...1.1 Uc -40-60 °C operational AC 60 Hz || 1...1.1 Uc 60-70 °C operational AC 50/60 Hz || 0.3...0.6 Uc -40-70 °C drop-out AC 50/60 Hz
Mounting Supportplate
Control Circuit TypeAC 50/60 Hz

Offer Sustainability

Rohs Exemption InformationYes
WeeeThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs RegulationPro-active China RoHS declaration (out of China RoHS legal scope)
Circularity ProfileENVEOLI1503009EN
Eu Rohs DirectiveCompliant
Mercury FreeYes
Environmental DisclosureENVPEP1503009EN
Sustainable Offer StatusGreen Premium product
Pvc FreeYes
Toxic Heavy Metal FreeYes
Reach RegulationFree of Substances of Very High Concern above the threshold
California Proposition 65WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
Reach Free Of SvhcYes

Environment

Product CertificationsDNV || LROS (Lloyds register of shipping) || CCC || CSA || BV || UL || GL || GOST || UKCA || RINA
Fire Resistance850 °C IEC 60695-2-1
Width75 mm
Depth119 mm
Height127 mm
StandardsCSA C22.2 No 14 || EN 60947-4-1 || EN 60947-5-1 || UL 508 || IEC 60947-4-1
Climatic WithstandIACS E10 exposure to damp heat
Net Weight1.4 kg
Flame RetardanceV1 conforming to UL 94
Ip Degree Of ProtectionIP2X VDE 0106 || IP2X IEC 60529
Mechanical Robustnessshocks contactor closed 15 Gn for 11 ms) || vibrations contactor opened 2 Gn, 5...300 Hz) || vibrations contactor closed 4 Gn, 5...300 Hz) || shocks contactor opened 10 Gn for 11 ms)
Operating Altitude0...9842.52 ft (0...3000 m)