contactor, TeSys F, 3P(3NO), AC-3, <=440V 115A, with coil LX9: 24...600V AC 40/400Hz, LX4: 24...460V DC, LXE: 100...250V AC 50/60Hz or 100…380V DC
- Manufactured by:
- Schneider Electric
TeSys F contactor, 3 poles (3NO), 115A/690V AC-3, for motor applications up to 55kW@400V. Contactor with no coil to allow a later selection and installation (coil to be ordered separately), it provides bolt terminals for bars or cables with lugs. For high operating rates until 2400 cycles/hour and environments until 55°C, it procures high reliability and durability. It makes installation and maintenance easy thanks to a drawer for insertion of the selected coil and a large choice of add-on blocks and accessories (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
Specifications
Certifications | ABS |
---|---|
Contact Configuration | 3 NO |
Depth | 171 mm |
Height | 162 mm |
Impedance | 0.37 MOhm - Ith 200 A 50 Hz |
Net Weight | 3.83 kg |
Standard | EN 60947-1 |
Storage Temperature | -60-80 °C |
Warranty Length | 18 months |
Width | 163.5 mm |
Specifications | |
[Ue] Rated Operational Voltage | <= 690 V AC 50/60 Hz || <= 460 V DC |
Motor Power Kw | 55 kW 380...400 V AC 50/60 Hz AC-3) || 59 kW 415 V AC 50/60 Hz AC-3) || 59 kW 440 V AC 50/60 Hz AC-3) || 75 kW 500 V AC 50/60 Hz AC-3) || 30 kW 220...240 V AC 50/60 Hz AC-3) || 80 kW 660...690 V AC 50/60 Hz AC-3) || 18.5 kW 400 V AC 50/60 Hz AC-4) |
Device Short Name | LC1F |
Contactor Application | resistive load || motor control |
Product Or Component Type | contactor |
Product Name | TeSys F |
Range | TeSys |
Pole Contact Composition | 3 NO |
[Ie] Rated Operational Current | 200 A 40 °C) <= 440 V AC-1 || 115 A 55 °C) <= 440 V AC-3 |
Utilisation Category | AC-1 || AC-4 || AC-3 |
Poles Description | 3P |
Contractual warranty | |
Warranty | 18 months |
Complementary | |
Product Certifications | RINA || ABS || CSA || DNV || RMRoS || BV || LROS (Lloyds register of shipping) || UL || CB || UKCA |
Irms Rated Making Capacity | 1150 A IEC 60947-4-1 |
Associated Fuse Rating | 125 A aM <= 440 V || 200 A gG <= 440 V |
[Uimp] Rated Impulse Withstand Voltage | 8 kV |
Inrush Power In Va | 590-855 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX9 coil || 543-665 VA (at 20 °C)with LX4 coil || 280-310 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil || 270-320 VA (at 20 °C)with LXE coil |
Connections - Terminals | power circuit lugs-ring terminals 1 95-95 mm² || power circuit connector 1 95-95 mm² || power circuit bar 2 20 x 3 mm || power circuit bolted connection || control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm²solid without cable end || control circuit screw clamp terminals 1 1-4 mm² || control circuit screw clamp terminals 2 1-4 mm² || control circuit screw clamp terminals 1.0 0.2-2.5 mm²flexible without cable end || control circuit screw clamp terminals 1.0 0.25-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1.0 0.2-2.5 mm²solid without cable end |
Maximum Operating Rate | 2400 cyc/h 55 °C |
Operating Time | 35 ms closing with LX9 coil || 130 ms opening with LX9 coil || 30...40 ms closing with LX4 coil || 30...50 ms opening with LX4 coil || 40...80 ms closing with LXE coil || 6...54 ms opening with LXE coil |
Tightening Torque | power circuit 10 N.m || control circuit 1.2 N.m || control circuit 0.6 N.m |
Mechanical Durability | 10 Mcycles |
Compatibility Code | LC1F |
Power Dissipation Per Pole | 15 W AC-1 || 5 W AC-3 |
Hold-In Power Consumption In Va | 6.6-8.1 VA, 40...400 Hz cos phi 0.9 (at 20 °C)with LX9 coil || 3.94-4.83 VA (at 20 °C)with LX4 coil || 4.5-7.0 VA, 50/60 Hz cos phi 0.5 (at 20 °C)with LXE coil || 2.5-4.0 VA (at 20 °C)with LXE coil |
Overvoltage Category | III |
[Ui] Rated Insulation Voltage | 1000 V IEC 60947-4-1 || 1500 V VDE 0110 group C |
[Icw] Rated Short-Time Withstand Current | 1100 A 40 °C - 10 s || 640 A 40 °C - 30 s || 520 A 40 °C - 1 min || 400 A 40 °C - 3 min || 320 A 40 °C - 10 min |
Heat Dissipation | 5.9-7.2 W || 2.2-5.5 W |
Average Impedance | 0.37 mOhm - Ith 200 A 50 Hz |
Control Circuit Voltage Limits | operational: 0.85...1.1 Uc AC 40...400 Hz with LX9 coil || drop-out: 0.2...0.55 Uc AC 40...400 Hz with LX9 coil || operational: 0.85...1.1 Uc DC with LX4 coil || drop-out: 0.15...0.2 Uc DC with LX4 coil || operational: 85...275 V AC 50/60 Hz with LXE coil || drop-out: 0...60 V AC 50/60 Hz with LXE coil || operational: 85...418 V DC with LXE coil || drop-out: 0...45 V DC with LXE coil |
[Ith] Conventional Free Air Thermal Current | 200 A 40 °C |
Standards | EN 60947-1 || JIS C8201-4-1 || IEC 60947-4-1 || EN 60947-4-1 || IEC 60947-1 |
[Uc] Control Circuit Voltage | 24...575 V AC 40...400 Hz with LX9 coil || 24...460 V DC with LX4 coil || 100...250 V AC 50/60 Hz with LXE coil || 100...380 V DC with LXE coil |
Mounting Support | plate |
Rated Breaking Capacity | 920 A IEC 60947-4-1 |
Offer Sustainability | |
Rohs Exemption Information | Yes |
Eu Rohs Directive | Compliant |
Mercury Free | Yes |
Environmental Disclosure | ENVPEP111201EN |
Sustainable Offer Status | Green Premium product |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Weee | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
China Rohs Regulation | Product out of China RoHS scope. Substance declaration for your information. |
Circularity Profile | ENVEOLI111214EN_V1 |
Environment | |
Mechanical Robustness | vibrations contactor open2 Gn, 5...300 Hz || vibrations contactor closed6 Gn, 5...300 Hz || shocks contactor open9 Gn for 1/2 sine wave (11 ms) || shocks contactor closed15 Gn for 1/2 sine wave (11 ms) |
Depth | 171 mm |
Permissible Ambient Air Temperature Around The Device | 60-70 °C at Uc |
Ambient Air Temperature For Operation | -40-60 °C |
Height | 162 mm |
Net Weight | 3.83 kg |
Ambient Air Temperature For Storage | -60-80 °C |
Protective Treatment | TH |
Ip Degree Of Protection | IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106 |
Operating Altitude | 9842.52 ft (3000 m) without derating |
Width | 163.5 mm |