Contactor, TeSys K, 3P, AC-3, lt or eq to 440V, 9A, 1 NO aux, 24VDC coil

Manufactured by:
Schneider Electric
Schneider electric

7cf18fc39e63219e418be32a4c4283d844613e3d medium
Price (VAT excluded)
€ 53.55
Nuova Elva code
LP4K0910BW3
Manufacturer code
LP4K0910BW3
Availability
1 in stock

TeSys K contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3 (4kW@400V). It provides a low consumption 24V DC coil with transient suppressor module, 1NO built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 600 cycles/hour in AC-3 and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

Specifications

CertificationsCB Scheme
Contact Configuration1 NO
Depth57 mm
Height58 mm
Impedance3 MOhm - Ith 20 A 50 Hz Power Circuit
Net Weight0.235 kg
StandardCSA C22.2 No 60947-4-1
Storage Temperature-50-80 °C
Warranty Length18 months
Width45 mm

Specifications

Auxiliary Contact Composition1 NO
Device Short NameLP4K
Range Of ProductTeSys K
Contactor Applicationresistive load || motor control
Product Or Component Typecontactor
RangeTeSys
Pole Contact Composition3 NO
Utilisation CategoryAC-3 || AC-4 || AC-1 || AC-3e
[Ie] Rated Operational Current20 A 50 °C) <= 440 V AC AC-1 power circuit || 9 A<= 440 V AC AC-3 power circuit || 16 A 70 °C) 690 V AC AC-1 power circuit || 9 A<= 440 V AC AC-3e power circuit
Poles Description3P

Contractual warranty

Warranty18 months

Complementary

Minimum Switching Current5 mA signalling circuit
Insulation Resistance> 10 MOhm signalling circuit
Rated Breaking Capacity110 A 415 V IEC 60947 || 110 A 440 V IEC 60947 || 80 A 500 V IEC 60947 || 110 A 220...230 V IEC 60947 || 110 A 380...400 V IEC 60947 || 70 A 660...690 V IEC 60947
Irms Rated Making Capacity110 A AC power circuit NF C 63-110 || 110 A AC power circuit IEC 60947 || 110 A AC signalling circuit IEC 60947
Associated Fuse Rating25 A gG <= 440 V power circuit || 25 A aM power circuit || 10 A gG signalling circuit IEC 60947 || 10 A gG signalling circuit VDE 0660
Net Weight0.235 kg
[Uimp] Rated Impulse Withstand Voltage8 kV
Coil Technologybuilt-in bidirectional peak limiting diode suppressor
Flame RetardanceV1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
Minimum Switching Voltage17 V signalling circuit
Maximum Operating Rate3600 cyc/h
[Ue] Rated Operational Voltagepower circuit 690 V AC 50/60 Hz || signalling circuit <= 690 V AC 50/60 Hz
Inrush Power In W1.8-1.8 W 20 °C)
Mechanical Durability30 Mcycles
Auxiliary Contacts Typeinstantaneous 1 NO
Operating Time10...20 ms coil de-energisation and NO opening || 30...40 ms coil energisation and NO closing
Width45 mm
Tightening Torque0.8-1.3 N.m screw clamp terminals Philips No 2 || 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm || 0.8-1.3 N.m screw clamp terminals pozidriv No 2
Overvoltage CategoryIII
Depth57 mm
[Ui] Rated Insulation Voltagepower circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || signalling circuit 690 V IEC 60947-4-1 || signalling circuit 690 V IEC 60947-5-1 || signalling circuit 600 V UL 508 || power circuit 600 V CSA C22.2 No 14 || signalling circuit 600 V CSA C22.2 No 14
Height58 mm
Average Impedance3 mOhm - Ith 20 A 50 Hz power circuit
Control Circuit Voltage Limitsoperational 0.7...1.30 Uc 50 °C) || drop-out 0.1...0.7 Uc 50 °C)
[Ith] Conventional Free Air Thermal Current20 A 50 °C power circuit || 10 A 50 °C signalling circuit
Mounting Supportplate || rail
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Hold-In Power Consumption In W1.8-1.8 W 20 °C

Offer Sustainability

Rohs Exemption InformationYes
China Rohs RegulationPro-active China RoHS declaration (out of China RoHS legal scope)
Circularity ProfileENVEOLI1503003EN
Eu Rohs DirectiveCompliant
Mercury FreeYes
Environmental DisclosureENVPEP1503003EN
Sustainable Offer StatusGreen Premium product
Toxic Heavy Metal FreeYes
Reach RegulationFree of Substances of Very High Concern above the threshold
California Proposition 65WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
Reach Free Of SvhcYes
WeeeThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.

Environment

Product CertificationsCB Scheme || CCC || UL || CSA || EAC || CE || UKCA
Ambient Air Temperature For Operation-25-50 °C
StandardsEN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1
Ambient Air Temperature For Storage-50-80 °C
Operating Altitude6561.68 ft (2000 m) without derating

Docs


Frequently bought together


Other Schneider Electric items

Request a quote