Motor controller, TeSys T, Motor Management, Modbus, 6 logic inputs, 3 logic outputs, 1.35 to 27A, 100 to 240VAC

Manufactured by:
Schneider Electric
Schneider electric

A804b657e08dbbe7381e51ffdaa983707870ad2b medium
Price (VAT excluded)
€ 628.20
Nuova Elva code
LTMR27MFM
Manufacturer code
LTMR27MFM
Availability
Standard lead time: 8 days

TeSys T is a motor management system that provides full motor monitoring, control, and protection when used with short circuit protection and a contactor. It manages most critical processes while reducing downtime and increasing productivity as well as predicts what will happen in the process, as it accurately monitors current, voltage, and power over a wide range. This motor management system is also a flexible system that supports six communication protocols which are Modbus™, CANopen, DeviceNet™, Profibus™, Ethernet/IP, and Modbus/TCP. TeSys T motor management system consist of several components which include the LTMR controller, the expansion module, HMI and software along with several accessories. The LTMR controller is the main component of the system that manages the basic functions. This includes the measurement of the ground current, motor temperature, three phase current of the motor, the controller also includes logic inputs and outputs which is used in fault management. The expansion module is directly connected to the controller and provides additional inputs as well as measure the voltage between the phases which allow the controller the monitor additional functions. TeSys T is highly reliable and has a very long product life thanks to a state-of-the-art component selection, to the all in one design and to the advanced electronic protection. TeSys T can be integrated in many different types of harsh environment such as dusty atmospheres, marine applications, high vibration applications and corrosive atmospheres and is used in Metal/Mining/Mineral, Oil & Gas, Water Wastewater. This is a TeSys T LTMR controller that measure current range of 1.35-27A with a supply voltage of 100-240 Vac and uses CANopen as the communication protocol. This controller measures temperature, phase current, imbalance current, average current and earth-fault current. The dimensions of this device are 61 mm (H) X 91 mm (W) X 122.5 mm (D) and it weighs 0.53 kg.

Specifications

CertificationsABS
Current8-62.8 mA
Depth122.5 mm
Height61 mm
Net Weight0.53 kg
StandardCSA C22.2 No 14
Storage Temperature-40-80 °C
Warranty Length18 months
Width91 mm

Specifications

Product Or Component Typemotor controller
Device Applicationequipment monitoring and control
Device Short NameLTMR
Product NameTeSys T
Measurement Current1.35-27 A
RangeTeSys
Current Consumption8...62.8 mA
[Us] Rated Supply Voltage100...240 V AC 50/60 Hz
Communication Port ProtocolModbus
Bus TypeModbus 2-wire RS 485 1...247 1.2...19.2 kbit/s, RJ45 2 shielded twisted pairs || Modbus 2-wire RS 485 1...247 1.2...19.2 kbit/s, terminal block 2 shielded twisted pairs
Supply Voltage Limits93.5-264 V AC

Contractual warranty

Warranty18 months

Complementary

Contacts Type And Composition1 NO + 1 NC fault signal || 3 NO
Input Current3.1 mA 100 V || 7.5 mA 240 V
Current State 1 Guaranteedlogic input 79...264 V >= 2 mA 25 ms
Net Weight0.53 kg
[Uimp] Rated Impulse Withstand Voltage4 kV supply, inputs and outputs EN/IEC 60947-4-1 || 6 kV current or voltage measurement circuit EN/IEC 60947-4-1 || 0.8 kV communication circuit EN/IEC 60947-4-1
Associated Fuse Rating4 A gG output || 0.5 A gG control circuit
Electromagnetic Compatibilityelectrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 || communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5 || control circuit: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 || radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3 || fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 || fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 || voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11 || conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 || temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5 || temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 || control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5
Measurement Accuracy5...15 % earth fault current internal measurement || 1 % voltage 100...830 V) || 3 % power factor || 5 % earth fault current external measurement || +/- 30 min/year internal clock || 0,02 Temperature || 1 % current || 5 % active and reactive power
Current State 0 Guaranteedlogic input 0...40 V <= 15 mA 25 ms
[Ui] Rated Insulation Voltage690 V EN/IEC 60947-1 || 690 V CSA C22.2 No 14 || 690 V UL 508
Short-Circuit Withstand100 kA EN/IEC 60947-4-1
Height61 mm
Compatibility CodeLTMR
Protection Typereverse polarity protection || overload (long time) || earth-leakage protection || phase unbalance || overload || load fluctuation || phase failure || power factor variation || thermal protection || locked rotor || thermal overload protection
Web Servicesweb server
Width91 mm
Load Current5 A 250 V AC logic output || 5 A 30 V DC logic output
Tightening Torquecontrol circuit 0.5-0.6 N.m flat 3 mm
Overvoltage CategoryIII
Depth122.5 mm
Maximum Operating Frequency2 Hz
Metering Typetemperature || phase current I1, I2, I3 RMS || average current Iavg || earth-fault current || imbalance current
Connection Pitch5.08 mm
Permissible Power480 VA AC-15), Ie = 2 A, 500000 cycles output) || 30 W DC-13), Ie = 1.25 A, 500000 cycles output)
Network And Machine Diagnosis Typefault recording || starting current and time || remaining operating time before overload tripping || waiting time after overload tripping || motor control command recording || event recording || trip history information || running hours counter/operating time || phase fault and earth fault trip counters || trip context information
Pollution Degree3
Logic Input Number6
Maximum Operating Rate1800 cyc/h
Connections - Terminalscontrol circuit connector 1 0.25-2.5 mm² AWG 24...AWG 14)flexible with cable end || control circuit connector 1 0.2-2.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 1 0.25-2.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 1 0.2-2.5 mm² AWG 24...AWG 14)solid without cable end || control circuit connector 2 0.2-1 mm² AWG 24...AWG 14)flexible with cable end || control circuit connector 2 0.2-1.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 2 0.5-1.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 2 0.2-1 mm² AWG 24...AWG 14)solid without cable end

Offer Sustainability

Rohs Exemption InformationYes
Eu Rohs DirectiveCompliant
Halogen Content PerformanceHalogen free plastic parts product
Mercury FreeYes
Environmental DisclosureENVPEP060308EN_V2
Sustainable Offer StatusGreen Premium product
Pvc FreeYes
Reach RegulationReference contains Substances of Very High Concern above the threshold
WeeeThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs RegulationProduct out of China RoHS scope. Substance declaration for your information.
Circularity ProfileENVEOLI100411EN_V2

Environment

Product CertificationsRMRoS || LROS (Lloyds register of shipping) || RINA || ABS || CCC || EAC || UL || GL || NOM || DNV || KERI || ATEX || BV || CSA || C-tick
Mechanical Robustnessvibrations mounted on symmetrical rail1 Gn, 5...300 Hz EN/IEC 60068-2-6 || vibrations plate mounted4 Gn, 5...300 Hz EN/IEC 60068-2-6 || shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27
Ambient Air Temperature For Operation-20-60 °C
StandardsCSA C22.2 No 14 || UL 508 || EN 60947-4-1 || IEC 60947-4-1 || IACS E10
Ambient Air Temperature For Storage-40-80 °C
Protective Treatment12 x 24 hour cycles EN/IEC 60068-2-30 || 48 h EN/IEC 60070-2-11 || TH EN/IEC 60068
Operating Altitude<= 6561.68 ft (2000 m) without derating
Fire Resistance650 °C EN/IEC 60695-2-12 || 960 °C UL 94
Ip Degree Of ProtectionIP20

Docs


Frequently bought together


Other Schneider Electric items

Request a quote