Reverser block for vertical mounting, TeSys Ultra, 32A/690V, coil 24VAC
- Manufactured by:
- Schneider Electric
- Price (VAT excluded)
- € 80.28
- Nuova Elva code
- LU2MB0B
- Manufacturer code
- LU2MB0B
- Availability
- Standard lead time: 8 days
TeSys U reversing module for vertical mounting, for the constitution of TeSys U reversing starter controllers. It provides reverse power contacts, coil control with interlocking capabilities to be supplied with 24V AC. To be used with an advanced power base LUB120 or LUB320 equipped with a Control Unit LUC*B type. To be associated with an assembling connector LU9MR1C and a control terminal block LU9M1 to complete the vertical mounting. Green Premium compliant (RoHS/REACh).
Specifications
Certifications | ASEFA |
---|---|
Current | 2360 mA |
Depth | 105 mm |
Height | 80 mm |
Mounting Type | Direct Mounting |
Net Weight | 0.4 kg |
Standard | CSA C22.2 No 60947-4-1, With Phase Barrier |
Storage Temperature | -40-85 °C |
Warranty Length | 18 months |
Width | 45 mm |
Specifications | |
Device Mounting | direct mounting |
[Uc] Control Circuit Voltage | 24 V AC 50/60 Hz |
Product Or Component Type | reverser block |
Current Consumption | 2360 mA 24 V AC I maximum while closing |
Range | TeSys |
[Ie] Rated Operational Current | 32 A |
Device Application | motor control |
Device Short Name | LU2MB |
Contractual warranty | |
Warranty | 18 months |
Complementary | |
Product Certifications | CE || UL || CSA || CCC || EAC || ASEFA || ATEX || Marine |
[Ui] Rated Insulation Voltage | 690 V IEC 60947-6-2 || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1 |
Compatibility Code | LU2MB |
Operating Time | 150 ms with change of direction || 75 ms without change of direction |
Width | 45 mm |
Tightening Torque | control circuit 0.8-1.2 N.m flat 5 mm || control circuit 0.8-1.2 N.m Philips No 2 5 mm || power circuit 1.9-2.5 N.m flat 6 mm || power circuit 1.9-2.5 N.m Philips No 2 6 mm |
Depth | 105 mm |
Network Frequency | 40...60 Hz |
[Ue] Rated Operational Voltage | 690 V AC power circuit |
Height | 80 mm |
Connections - Terminals | control circuit screw clamp terminals 1 0.34-1.5 mm² 3 mm) flexible with cable end || control circuit screw clamp terminals 1 0.75-1.5 mm² 3 mm) flexible without cable end || control circuit screw clamp terminals 1 0.75-1.5 mm² 3 mm) rigid || control circuit screw clamp terminals 2 0.34-1.5 mm² 3 mm) flexible with cable end || control circuit screw clamp terminals 2 0.75-1.5 mm² 3 mm) flexible without cable end || control circuit screw clamp terminals 2 0.75-1.5 mm² 3 mm) rigid || power circuit screw clamp terminals 1 1-10 mm² 4 mm) rigid || power circuit screw clamp terminals 1 1-6 mm² 4 mm) flexible with cable end || power circuit screw clamp terminals 1 2.5-10 mm² 4 mm) flexible without cable end || power circuit screw clamp terminals 2 1-6 mm² 4 mm) flexible with cable end || power circuit screw clamp terminals 2 1-6 mm² 4 mm) rigid || power circuit screw clamp terminals 2 1.5-6 mm² 4 mm) flexible without cable end |
Net Weight | 0.4 kg |
Fixing Mode | plug-in |
[Uimp] Rated Impulse Withstand Voltage | 6 kVIEC 60947-6-2 |
Inrush Restraint Duration | 25 ms AC || 15 ms DC |
Standards | EN 60947-6-2 || IEC 60947-6-2 || UL 60947-4-1, with phase barrier || CSA C22.2 No 60947-4-1, with phase barrier |
Offer Sustainability | |
Rohs Exemption Information | Yes |
Mercury Free | Yes |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov |
Weee | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
China Rohs Regulation | Product out of China RoHS scope. Substance declaration for your information. |
Eu Rohs Directive | Compliant |
Environment | |
Ambient Air Temperature For Operation | -25-60 °C with LUCM || -25-70 °C with LUCA, LUCB, LUCC, LUCD |
Operating Altitude | 6561.68 ft (2000 m) |
Fire Resistance | 960 °C parts supporting live components IEC 60695-2-12 || 650 °C IEC 60695-2-12 |
Immunity To Radioelectric Fields | 10 V IEC 61000-4-6 |
Resistance To Fast Transients | 2 kV 3 serial link IEC 61000-4-4 || 4 kV 4 all circuits except for serial link IEC 61000-4-4 |
Resistance To Radiated Fields | 10 V/m level 3 IEC 61000-4-3 |
Non-Dissipating Shock Wave | 1 kV serial mode IEC 60947-6-2 || 2 kV common mode IEC 60947-6-2 |
Shock Resistance | 10 gn power poles open IEC 60068-2-27 || 15 gn power poles closed IEC 60068-2-27 |
Vibration Resistance | 2 gn 5-300 Hz) power poles open IEC 60068-2-27 || 4 gn 5-300 Hz) power poles closed IEC 60068-2-27 |
Ambient Air Temperature For Storage | -40-85 °C |
Protective Treatment | TH IEC 60068 |
Ip Degree Of Protection | IP20 IEC 60947-1 front panel and wired terminals) || IP20 IEC 60947-1 other faces) || IP40 IEC 60947-1 front panel outside connection zone) |
Resistance To Electrostatic Discharge | 8 kV level 3, in open air IEC 61000-4-2 || 8 kV level 4, on contact IEC 61000-4-2 |