Standard control unit, TeSys Ultra, 0.15A to 0.6A, 3P motors, thermal magnetic protection, class 10, coil 24VDC

Manufactured by:
Schneider Electric
Schneider electric

D338b8499bbb13202f02be0108f93b89003b8254 medium
Price (VAT excluded)
€ 107.24
Nuova Elva code
LUCAX6BL
Manufacturer code
LUCAX6BL
Availability
Standard lead time: 7 days

TeSys U standard control unit to be inserted in power bases LUB12, LUB32, LUB38 to form a TeSys U starter controller, for 3-phase motor applications up to 0.09kW@400V. It provides full protection to motors with a rated current Ir 0.15-0.6A (Ir adjustable), overload tripping class 10, short circuit at 13 x Irmax, overcurrent at 14.2 x Ir, phase loss, insulation fault (protection of equipment only). To be used with a 24V DC voltage for the control of the starter (through the control terminals A1/A2 located in the power base). Certified when used in conjunction with a LUB power base (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Specifications

CertificationsASEFA
Depth60 mm
Height66 mm
Net Weight0.135 kg
StandardCSA C22.2 No 60947-4-1, With Phase Barrier
Storage Temperature-40-85 °C
Warranty Length18 months
Width45 mm

Specifications

[Uc] Control Circuit Voltage24 V DC
RangeTeSys
Utilisation CategoryAC-43 || AC-44 || AC-41
Function Availableearth fault protection || protection against overload and short-circuit || protection against phase failure and phase imbalance || manual reset
Tripping Threshold14.2 x Ir +/- 20 %
Product Compatibilitypower base LUB12 || power base LUB32 || power base LUB38 || power base LUB120 || power base LUB320 || power base LUB380 || reversing contactor breaker LU2B12BL || reversing contactor breaker LU2B32BL || reversing contactor breaker LU2B38BL
Product Specific Applicationbasic protection requirements for motor starters: overload and short-circuit
Network Frequency40...60 Hz
Load Type3-phase motor self-cooled
Device Applicationmotor control || motor protection
Device Short NameLUCA
[Ue] Rated Operational Voltage690 V AC
Range Of ProductTeSys Ultra
Phase Failure Sensitivityyes
Thermal Protection Adjustment Range0.15-0.6 A
Product Or Component Typestandard control unit
Product NameTeSys Ultra
Thermal Overload Classclass 10 40-60 Hz -25-70 °C IEC 60947-6-2 || class 10 40-60 Hz -25-70 °C UL 508
Motor Power Kw0.09 kW 400...440 V AC 50/60 Hz

Contractual warranty

Warranty18 months

Complementary

Product CertificationsCE || UL || CSA || CCC || EAC || ASEFA || ATEX || Marine
Control Circuit Voltage Limits20...27 V DC 24 V in operation || 14.5 V DC 24 V drop-out
Operating Time35 ms opening with LUB12 control circuit || 35 ms opening with LUB32 control circuit || 35 ms opening with LUB38 control circuit || 70 ms closing with LUB12 control circuit || 70 ms closing with LUB32 control circuit || 70 ms closing with LUB38 control circuit
Width45 mm
Safe Separation Of Circuit400 V SELV between the control and auxiliary circuits IEC 60947-1 || 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
Depth60 mm
Heat Dissipation2-2 W control circuit with LUB12 || 3-3 W control circuit with LUB32 || 3-3 W control circuit with LUB38
Height66 mm
Net Weight0.135 kg
Fixing Modeplug-in front face)
[Uimp] Rated Impulse Withstand Voltage6 kV IEC 60947-6-2
StandardsEN 60947-6-2 || IEC 60947-6-2 || UL 60947-4-1, with phase barrier || CSA C22.2 No 60947-4-1, with phase barrier
Typical Current Consumption130 mA 24 V DC I maximum while closing with LUB12 || 220 mA 24 V DC I maximum while closing with LUB32 || 220 mA 24 V DC I maximum while closing with LUB38 || 60 mA 24 V DC I rms sealed with LUB12 || 80 mA 24 V DC I rms sealed with LUB32 || 80 mA 24 V DC I rms sealed with LUB38
[Ui] Rated Insulation Voltage690 V IEC 60947-6-2 || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1
Compatibility CodeLUCA

Offer Sustainability

Rohs Exemption InformationYes
Eu Rohs DirectiveCompliant
Halogen Content PerformanceHalogen free plastic parts product
Mercury FreeYes
Environmental DisclosureENVPEP080204EN
Sustainable Offer StatusGreen Premium product
Pvc FreeYes
Reach RegulationReference contains Substances of Very High Concern above the threshold
WeeeThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs RegulationProduct out of China RoHS scope. Substance declaration for your information.
Circularity ProfileENVEOLI100414

Environment

Ambient Air Temperature For Operation-25-70 °C
Resistance To Electrostatic Discharge8 kV 3 in open air IEC 61000-4-2 || 8 kV 4 on contact IEC 61000-4-2
Operating Altitude6561.68 ft (2000 m)
Fire Resistance960 °C parts supporting live components IEC 60695-2-12 || 650 °C IEC 60695-2-12
Immunity To Radioelectric Fields10 V IEC 61000-4-6
Resistance To Fast Transients2 kV 3 serial link IEC 61000-4-4 || 4 kV 4 all circuits except for serial link IEC 61000-4-4
Resistance To Radiated Fields10 V/m 3 IEC 61000-4-3
Shock Resistance10 gn power poles open IEC 60068-2-27 || 15 gn power poles closed IEC 60068-2-27
Vibration Resistance2 gn 5-300 Hz power poles open IEC 60068-2-6 || 4 gn 5-300 Hz power poles closed IEC 60068-2-6
Immunity To Microbreaks3 ms
Immunity To Voltage Dips70 % / 500 ms IEC 61000-4-11
Ip Degree Of ProtectionIP20 front panel and wired terminals IEC 60947-1 || IP20 other faces IEC 60947-1 || IP40 front panel outside connection zone IEC 60947-1
Ambient Air Temperature For Storage-40-85 °C
Protective TreatmentTH IEC 60068

Docs


Frequently bought together


Other Schneider Electric items

Request a quote