Residual current circuit breaker (RCCB), Multi9 GFP, 4P, 25A, A-SI type, 86mA

Manufactured by:
Schneider Electric
Schneider%20electric

7f07b96cb22692daebfeb6f294fb3647bd01256f medium
Price (VAT excluded)
€ 287.46
Nuova Elva code
M9R12425
Manufacturer code
M9R12425
Availability
Send request for quotation

This Multi GFP product is a residual current circuit breaker (RCCB). It is a 4P circuit breaker with 25A In rated current, 86mA earth leakage sensitivity and A-SI type protection class. It protects persons against electric shock by direct contact. It also protects installations against fire risks. The tripping upon fault is indicated by a red mechanical status indicator on the front panel. The A-SI type offers enhanced immunity to electrical disturbances. This product is dedicated to original equipment manufacturers (OEM) and control panel builders in indisutrial and tertiary buildings. It is compliant with IEC/EN 61008-1 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 1500A. The (Inc/IΔc) conditional rated short circuit current is 10kA. It has a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 240VAC. The Ui rated insulation voltage is 440VAC. The Uimp rated impulse withstand voltage is 6kV. The frequency is 50Hz or 60Hz. It is DIN rail mountable. The width in 9mm pitches is 8. The product colour is light grey (RAL7035). The dimensions are (W) 72mm x (H) 81mm x (D) 60mm. The weight is 0.45kg. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is from -25°C to 60°C. The storage temperature is from -40°C to 70°C.

Specifications

CertificationsIEC
ColorGray
Depth60 mm
Height81 mm
Line Rated Current40 °C
Mounting TypeClip-On
Net Weight0.45 kg
StandardEN/IEC 61008-1
Storage Temperature-40-70 °C
Strip Length14 mm
Width72 mm

Specifications

Line Rated Current25 A 40 °C EN/IEC 61008-1
Poles Description4P
Neutral Positionleft
Device Applicationdistribution
Device Short NameGFP
Network TypeAC
Earth-Leakage Protection Classtype A-SI (Super Immunised)
Earth-Leakage Sensitivity86 mA UL 1053 || 100 mA EN/IEC 61008-1
Product Or Component Typeresidual current circuit breaker (RCCB)
Product NameMulti9 GFP
Utilisation CategoryAC-23A EN/IEC 61008-1
RangeMulti9
Earth-Leakage Protection Time Delayinstantaneous

Complementary

Network Frequency50/60 Hz
Control Typetoggle
Residual Current Tripping Technologyvoltage independent
[Ui] Rated Insulation Voltage440 V AC 50/60 Hz
Mounting Modeclip-on
Rated Breaking And Making CapacityIdm 1500 A EN/IEC 61008-1
Mechanical Durability20000 cycles
Local SignallingON, OFF, fault trip
[Uimp] Rated Impulse Withstand Voltage6 kVEN/IEC 61008-1
ColorGray
Width72 mm
Height81 mm
Depth60 mm
Tightening Torque3.5-3.5 N.m top or bottom
Rated Conditional Short-Circuit CurrentInc 10 kA 100 A gG
[Ue] Rated Operational Voltage415 V AC 50 Hz || 480Y/277 V AC 60 Hz
Contact Position Indicatoryes
Locking Options Descriptionpadlocking in OFF position
Mounting SupportDIN rail
9 Mm Pitches8
Connections - Terminalstunnel type terminals top or bottom) 1-25 mm² AWG 18...AWG 3) - flexible || tunnel type terminals top or bottom) 1-35 mm² AWG 18...AWG 2) - rigid || tunnel type terminals top or bottom) 1-25 mm² AWG 18...AWG 3) - flexible with ferrule
Net Weight0.45 kg
Wire Stripping Length14 mm top or bottom

Offer Sustainability

WeeeThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Eu Rohs DirectiveUnder investigation

Environment

Ambient Air Temperature For Operation-25-60 °C
Tropicalisation2 IEC 60068-1
StandardsEN/IEC 61008-1 || UL 1053
Product CertificationsIEC || UL
Electromagnetic Compatibility8/20 µs impulse withstand, 3000 A EN/IEC 61008-1
Ip Degree Of ProtectionIP20 conforming to IEC 60529 || IP40 (modular enclosure) conforming to IEC 60529
Pollution Degree3
Ambient Air Temperature For Storage-40-70 °C
Relative Humidity95-95 % 55-55 °C

Docs


Other Schneider Electric items

Request a quote