Modular timing relay, Harmony, 8A, 2CO, 0.3s…30s, star delta, 24...240V AC DC

Manufactured by:
Schneider Electric
Schneider%20electric

39c8392dfe2680455672a6e3a2cd75af8d277760 medium
Price (VAT excluded)
€ 56.93
Nuova Elva code
RE22R2QEMR
Manufacturer code
RE22R2QEMR
Availability
Send request for quotation

This Harmony RE22 modular single function timer can be set between 1 seconds and 300 hours." "It provides function Qe and it is mountable on DIN rail." "This modular single function timing relay is ideal for providing timing control in automation systems such as automatic door opening, alarm, lighting in toilets and car park barriers." "It has one of market slimmest form-factors with 22.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 2-pole DIN device." "It also offers a sealable cover, simple and precise settings with rotary trimmers." "Selectable timing range offers a one stop solution for your power management system." "Single function timer for a simple integration in hard-wired logic schematics, ideal for refurbishment of old installations without using a PLC." 0 0 0 0 0 0 0 0 0

Specifications

CertificationsCCC
Input Voltage2.4 V
Net Weight0.09 kg
StandardIEC 61812-1
Storage Temperature-40-70 °C
Width22.5 mm

Specifications

Discrete Output Typerelay
Range Of ProductHarmony Timer Relays
Product Or Component Typesingle function relay
Nominal Output Current8 A
Device Short NameRE22

Complementary

Power Consumption In W1.5 W 240 V DC
Power Consumption In Va3-3 VA 240 V AC
Switching Capacity In Va2000 VA
Maximum Switching Current8 A
Voltage Range0.85...1.1 Us
Net Weight0.09 kg
Mounting Positionany position
Voltage Drift+/- 0.2 %/V
Reset Time120 ms on de-energisation
Maximum Switching Voltage250 V AC
Connections - Terminalsscrew terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end || screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end || screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end || screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end
Safety Reliability DataB10d = 320000 || MTTFd = 353.8 years
[Us] Rated Supply Voltage24...240 V AC/DC 50/60 Hz
Temperature Drift+/- 0.05 %/°C
Time Delay Range0.3...30 s
Minimum Switching Current10 mA 5 V DC
Overvoltage CategoryIII IEC 60664-1
Input Voltage<= 2.4 V
Mounting Support35 mm DIN rail conforming to EN/IEC 60715
Electrical Durability100000 cycles, 8 A at 250 V, AC-1 || 100000 cycles, 2 A at 24 V, DC-1
Mechanical Durability10000000 cycles
Housing Materialself-extinguishing
Contacts Type And Composition2 C/O timed contact, cadmium free
Status LedGreen LED backlight steady)dial pointer indication || Yellow LED steady)output relay energised || Yellow LED fast flashing)timing in progress and output relay de-energised || Yellow LED slow flashing)timing in progress and output relay energised
[Uimp] Rated Impulse Withstand Voltage5 kV 1.2-50 µs IEC 60664-1
Width22.5 mm
Time Delay Typestar-delta
Tightening Torque0.6-1 N.m IEC 60947-1
Supply Frequency50...60 Hz +/- 5 %
Repeat Accuracy+/- 0.5 % IEC 61812-1
Setting Accuracy Of Time Delay+/- 10 % of full scale 25 °C IEC 61812-1
Creepage Distance4 kV/3 IEC 60664-1
Maximum Delay Response100 ms
Control Typerotary knob || diagnostic button
Insulation Resistance100 MOhm 500 V DC IEC 60664-1
Immunity To Microbreaks10 ms

Offer Sustainability

Rohs Exemption InformationYes
Mercury FreeYes
Environmental DisclosureENVPEP1401008EN
Sustainable Offer StatusGreen Premium product
Reach RegulationReference contains Substances of Very High Concern above the threshold
California Proposition 65WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
China Rohs RegulationX
Circularity ProfileENVEOLI1401008EN
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)

Environment

Product CertificationsCE || CSA || GL || EAC || UL || RCM || CCC
Ambient Air Temperature For Storage-40-70 °C
Relative Humidity95-95 % 25-55 °C
Ip Degree Of Protectionhousing IP40 IEC 60529 || terminals IP20 IEC 60529 || front panel IP50 IEC 60529
Ambient Air Temperature For Operation-20-60 °C
StandardsIEC 61812-1 || UL 508
Electromagnetic Compatibilityfast transients immunity test 1 kV capacitive connecting clip)level 3 IEC 61000-4-4 || surge immunity test 1 kV differential mode)level 3 IEC 61000-4-5 || surge immunity test 2 kV common mode)level 3 IEC 61000-4-5 || electrostatic discharge 6 kV contact discharge)level 3 IEC 61000-4-2 || electrostatic discharge 8 kV air discharge)level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test 10 V/m 80 MHz...1 GHz)level 3 IEC 61000-4-3 || conducted RF disturbances 10 V 0.15...80 MHz)level 3 IEC 61000-4-6 || fast transient bursts 2 kV direct contact)level 3 IEC 61000-4-4 || immunity to microbreaks and voltage drops 30 % 500 ms) IEC 61000-4-11 || immunity to microbreaks and voltage drops 100 % 20 ms) IEC 61000-4-11
Dielectric Strength2.5 kV 1 mA/1 minute 50 Hz between relay output and power supply basic insulation IEC 61812-1
Shock Resistance15 gn not operating 11 ms IEC 60068-2-27 || 5 gn in operation 11 ms IEC 60068-2-27
Vibration Resistance20 m/s² 10-150 Hz)IEC 60068-2-6
Pollution Degree3 IEC 60664-1
Directives2006/95/EC - low voltage directive || 2004/108/EC - electromagnetic compatibility

Docs


Other Schneider Electric items

Request a quote