This Harmony RE48 timing relay can be set between 0.2 seconds and 300 hours, has an output rating of 5A, is 22.5mm wide and can be supplied with 24V to 240V AC. It is a plug-in device, meaning it is quick and easy to install with the need for tools. It also offers a sealable cover, simple and precise settings with rotary trimmers. This relay offers L, Li flashing functions. It is designed for both panel mooting or socket plug in, this gives more flexibility in designing installations and stocking spares. Single function timer for a simple integration in hard-wired logic schematics, ideal for refurbishment of old installations without using a PLC. Status display with 2 LEDs, visually inspect the status of you system without specialized tools. 0 0 0 0 0 0 0 0 0 0 0 0
Specifications
Certifications | C-tick |
---|---|
Line Rated Current | 5 A |
Net Weight | 0.14 kg |
Output Voltage | 2 A |
Standard | 73/23/EEC |
Storage Temperature | -40-70 °C |
Warranty Length | 18 months |
Specifications | |
Voltage Range | 0.85...1.1 Us AC || 0.9...1.1 Us DC |
Electrical Connection | plug-in sub-base 11 |
Time Delay Type | asymmetrical flashing |
Contacts Type And Composition | 2 C/O timed contacts, AgNi (cadmium free) |
Discrete Output Type | relay |
Range Of Product | Harmony Timer Relays |
Product Or Component Type | dual function relay |
Component Name | RE48A |
[Us] Rated Supply Voltage | 24...240 V AC/DC 50/60 Hz |
Time Delay Range | 0.2...12 min || 5...300 s || 0.02...1.2 s || 0.5...30 min || 5...300 h || 0.2...12 h || 0.2...12 s || 0.5...30 s || 2...120 s || 0.05...3 s || 2...120 min || 5...300 min || 0.5...30 h || 2...120 h |
Line Rated Current | 5 A |
Contractual warranty | |
Warranty | 18 months |
Complementary | |
Output Voltage | 240 V 5 A AC-12 || 30 V 2 A DC-13 || 240 V 1.5 A AC-15 |
Product Front Plate Size | 48 x 48 mm |
Net Weight | 0.14 kg |
Minimum Pulse Duration | 20 ms |
Reset Time | 25 ms on de-energisation |
Power Consumption In Va | 1.1 VA 24 V || 4.8 VA 240 V |
Maximum Switching Voltage | 250 V AC/DC |
Surge Withstand | 1 kV differential mode IEC 61000-4-5 level 3 || 2 kV common mode IEC 61000-4-5 level 3 |
Voltage Drift | +/- 0.2 %/V of the maximum setting value 48...240 V || +/- 1 %/V of the maximum setting value 24...48 V |
Electrical Durability | 100000 cycles |
Minimum Switching Current | 100 mA |
Power Consumption In W | 0.5 W 24 V || 1.7 W 240 V |
Local Signalling | for output relay state 1 LED (yellow) || for flashing: relay energised timing in progress LED indicator (green) || for on steady: relay energised, no timing in progress LED indicator (green) |
Mechanical Durability | 30000000 cycles |
On-Load Factor | 100 % |
Housing Material | self-extinguishing |
Breaking Capacity | 1250 VA |
Repeat Accuracy | +/- 0.2 % of the maximum setting value IEC 61812-1 |
Setting Accuracy Of Time Delay | +/- 5 % of full scale 25 °C IEC 61812-1 |
Control Type | selector switch front panel |
Mounting Support | base mounted: socket || panel mounted: system supplied with the product |
Temperature Drift | +/- 0.02 %/°C of the maximum setting value IEC 61812-1 |
Pick Up Duration | 55 ms |
Maximum Switching Current | 5 A |
Marking | CE |
Offer Sustainability | |
Rohs Exemption Information | Yes |
Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Mercury Free | Yes |
Environmental Disclosure | ENVPEP1512002EN |
Sustainable Offer Status | Green Premium product |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Weee | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
China Rohs Regulation | X |
Circularity Profile | ENVEOLI1512002EN |
Environment | |
Product Certifications | UL || C-tick || cULus || CSA |
Ip Degree Of Protection | IP40 IEC 60529 housing) || IP50 IEC 60529 front face) |
Ambient Air Temperature For Storage | -40-70 °C |
Relative Humidity | 93-93 % without condensation IEC 60068-2-3 |
Resistance To Electrostatic Discharge | 6 kV in contact EN/IEC 61000-4-2 level 3 || 8 kV in air EN/IEC 61000-4-2 level 3 |
Humidity Drift | +/- 0.05 %/%RH of the maximum setting value IEC 61812-1 |
Immunity To Radioelectric Fields | 10 V 0.15...80 MHz)EN/IEC 61000-4-6 level 3 |
Resistance To Fast Transients | 2 kV EN/IEC 61000-4-4 level 4 capacitive connecting clip) || 4 kV EN/IEC 61000-4-4 level 4 direct) |
Dielectric Strength | 1 kV 1 mA/1 minute IEC 61812-1 |
Ambient Air Temperature For Operation | -20-50 °C |
Resistance To Electromagnetic Fields | 10 V/m 26 MHz to 1 GHz EN/IEC 61000-4-3 level 3 |
Standards | EN 50081-1/2 || EN 50082-1/2 || IEC 61812-1 || 93/68/EEC || 89/336/EEC || IEC 60669-2-3 || 73/23/EEC |
Disturbance Radiated/Conducted | class B 0.15...30 MHz EN 55022 (EN 55011 group 1) |
Immunity To Microbreaks | 10 ms |
Protection Against Electric Shocks | 4 kV class III IEC 60664-1 || 4 kV class III IEC 61812-1 |
Immunity To Voltage Dips | 30 % / 10 ms EN/IEC 61000-4-11 || 60 % / 100 ms EN/IEC 61000-4-11 || 95 % / 5 s EN/IEC 61000-4-11 |
Vibration Resistance | 0.35 mm 10-55 Hz)IEC 60068-2-6 |