Modular smart relay, Zelio Logic, 26 I/O, 24 V DC, clock, display

Manufactured by:
Schneider Electric
Schneider electric

05c5a15b3167954ea71d16f9b44a15751e01eb9a medium
Price (VAT excluded)
€ 260.93
Nuova Elva code
SR3B262BD
Manufacturer code
SR3B262BD
Availability
Standard lead time: 7 days

This Zelio Logic SR3 compact smart relay / programmable controller uses a supply voltage of 24V direct current. It has 26 inputs / outputs with screw-clamp terminals. It has compact design, allowing installation on DIN rail. It also offers simple programming, display and diagnosing of malfunctions display and navigation buttons. Its simple ladder programming makes it adapted for non-specialists.

Specifications

CertificationsC-tick
Net Weight0.3 kg
Number of Outputs10
Output Voltage24 V
StandardEN/IEC 60068-2-27 Ea
Storage Temperature-40-70 °C
Warranty Length18 months

Specifications

Range Of ProductZelio Logic
Product Or Component Typemodular smart relay

Contractual warranty

Warranty18 months

Complementary

Output Voltage24 V transistor output
Backup Time10 years 25 °C
Clock Drift12 min/year 0-55 °C || 6 s/month 25-25 °C
Analogue Input Typecommon mode
Overload Protectionwith transistor output
Discrete Input Current4 mA
Current State 1 Guaranteed>= 1.2 mA IB...IG used as discrete input circuit) || >= 2.2 mA I1...IA and IH...IR discrete input circuit)
Response Time<= 1 ms from state 0 to state 1)transistor output || <= 1 ms from state 1 to state 0)transistor output
Clockwith
Overvoltage Protectionwith transistor output
Power Dissipation In W10 W with extensions || 5 W without extension
Input Impedance12 kOhm IB...IG used as analogue input circuit || 12 kOhm IB...IG used as discrete input circuit || 7.4 kOhm I1...IA and IH...IR discrete input circuit
Local Displaywith
Net Weight0.3 kg
[Uimp] Rated Impulse Withstand Voltage4 kV EN/IEC 60947-1 and EN/IEC 60664-1
Voltage State 0 Guaranteed<= 5 V I1...IA and IH...IR discrete input circuit || <= 5 V IB...IG used as discrete input circuit
Output Voltage Limits19.2...30 V DC transistor output)
Conversion Timesmart relay cycle time analogue input circuit
Connections - Terminalsscrew terminals, 1 x 0.2...1 x 2.5 mm² AWG 25...AWG 14) semi-solid || screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 25...AWG 14) solid || screw terminals, 1 x 0.25...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end || screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) solid || screw terminals, 2 x 0.25...2 x 0.75 mm² AWG 24...AWG 18) flexible with cable end
Analogue Input Number6
Voltage State 1 Guaranteed>= 15 V I1...IA and IH...IR discrete input circuit || >= 15 V IB...IG used as discrete input circuit
Input Compatibility3-wire proximity sensors PNP discrete input
Discrete Input Typeresistive
Current State 0 Guaranteed<= 0.5 mA IB...IG used as discrete input circuit) || <= 0.75 mA I1...IA and IH...IR discrete input circuit)
Supply Voltage Limits19.2-30 V
Short-Circuit Protectionwith transistor output
Operating Distance10 m between stations, with screened cable (sensor not isolated) analogue input circuit
Overvoltage CategoryIII EN/IEC 60664-1
Maximum Supply Current180 mA with extensions) || 70 mA without extension)
Tightening Torque0.5 N.m
Temperature Probe TypeNTC 10k 25 °C || NTC 1000k 25 °C || KTY81 210/220/221/222/250 || Pt 500
Load Current0.5-0.625 A transistor output
Analogue Input Resolution8 bits
Number Of Outputs10 transistor
Counting Frequency1 kHz discrete input
[Ures] Residual Voltage2 V at state 1 transistor output
Discrete Input Number16 EN/IEC 61131-2 type 1
Cycle Time6-90 ms
Reverse Polarity Protectionwith
Maximum Permissible Voltage30 V analogue input circuit
Repeat Accuracy+/- 2 % 55 °C analogue input circuit
[Us] Rated Supply Voltage24 V
Checksprogram memory on each power up
Analogue Input Range0...24 V || 0...10 V
Conversion Error+/- 5 % 25 °C analogue input circuit || +/- 6.2 % 55 °C analogue input circuit
Discrete Input Voltage24 V DC
Number Or Control Scheme Lines0-500 FBD || 0-240 ladder
Lsb Value39 mV analogue input circuit

Offer Sustainability

Rohs Exemption InformationYes
Circularity ProfileENVEOLI0604006EN
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)
Mercury FreeYes
Environmental DisclosureENVPEP060406EN
Sustainable Offer StatusGreen Premium product
Pvc FreeYes
Reach RegulationReference contains Substances of Very High Concern above the threshold
California Proposition 65WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
WeeeThe product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs RegulationX

Environment

Product CertificationsC-tick || GOST || UL || CSA || GL
Relative Humidity95-95 % without condensation or dripping water
Maximum Altitude Transport3048 m
Operating Altitude6561.68 ft (2000 m)
StandardsEN/IEC 60068-2-27 Ea || EN/IEC 61000-4-5 || EN/IEC 61000-4-11 || EN/IEC 61000-4-6 level 3 || EN/IEC 61000-4-12 || EN/IEC 61000-4-4 level 3 || EN/IEC 61000-4-3 || EN/IEC 61000-4-2 level 3 || EN/IEC 60068-2-6 Fc
Disturbance Radiated/Conductedclass B EN 55022-11 group 1
Ambient Air Temperature For Operation-20-40 °C in non-ventilated enclosure IEC 60068-2-1 and IEC 60068-2-2 || -20-55 °C IEC 60068-2-1 and IEC 60068-2-2
Immunity To Microbreaks1 ms
Environmental CharacteristicEMC directive EN/IEC 61000-6-2 || EMC directive EN/IEC 61000-6-3 || EMC directive EN/IEC 61000-6-4 || EMC directive EN/IEC 61131-2 zone B || low voltage directive EN/IEC 61131-2
Ip Degree Of ProtectionIP20 IEC 60529 terminal block) || IP40 IEC 60529 front panel)
Pollution Degree2 EN/IEC 61131-2
Ambient Air Temperature For Storage-40-70 °C

Docs