Solid state relay, Harmony, 50A, panel mount, zero voltage switching, thermal pad, input 90…280V AC, output 24…300V AC
- Manufactured by:
- Schneider Electric
- Price (VAT excluded)
- € 46.73
- Nuova Elva code
- SSP1A150M7T
- Manufacturer code
- SSP1A150M7T
- Availability
- Send request for quotation
This Harmony SSP solid state panel mount single-phase relay is rated 50A, is controlled with a 90V to 280V AC input, has a rated load voltage of 24V to 300V AC with zero voltage switching, ideal for resistive loads. It has a visual indicator showing the status of its input and a alarm output enabling a quick response to unexpected events. It also has a test button for easy debugging, testing and commissioning. It is also silent and reliable thanks to the absence of moving contacts. 0 0 0 0 0 0 0 0 0 0 0 0
Specifications
Certifications | CE |
---|---|
Line Rated Current | 50 A |
Net Weight | 89.2 g |
Number of Phases | 1 |
Output Voltage | 24-300 V |
Standard | CSA C22.2 No 14-13 |
Storage Temperature | -40-125 °C |
Specifications | |
Range Of Product | Harmony Solid State Relays |
Output Switching Mode | zero voltage switching |
Product Or Component Type | solid state relay up to 50 A |
Phase | 1 phase |
Solid State Output Type | zero voltage switching || SCR output |
Provided Equipment | thermal pad |
Line Rated Current | 50 A |
Device Short Name | SSP1 |
Complementary | |
Safety Reliability Data | MTTFd = 1875.9 years || B10d = 1731395 |
Maximum Voltage Drop | <1.15 V on-state |
Connections - Terminals | screw terminals 0.2...3.3 mm², AWG 24...AWG 12) with cable end input || screw terminals 0.5...5.26 mm², AWG 20...AWG 10) with cable end output || screw terminals 0.2...3.3 mm², AWG 24...AWG 12) without cable end input || screw terminals 0.5...8.26 mm², AWG 20...AWG 8) without cable end output || forked type tag connectors 9.2 x 4 mm input || ring lugs 9.2 x 4 mm input || forked type tag connectors 11.7 x 4.5 mm output || ring lugs 11.7 x 4.5 mm output |
Dielectric Strength | 4 kV AC for input/output || 4 kV AC for input or output to case |
Response Time | 30 ms (turn-off) || 25 ms (turn-on) |
Surge Current | 625 A 16.6 ms |
Load Current | 0.15-50 A |
Local Signalling | LED, green input |
Net Weight | 89.2 g |
[Uimp] Rated Impulse Withstand Voltage | 6 kV output to case || 6 kV input to output |
Minimum Switching Voltage | 90 V AC turn-on |
Cos Phi | 0.5-0.5 (with maximum load) |
Maximum Leakage Current | 1 mA off-state |
Thermal Impedance | 0.48 °C-in²/W at 25 psi |
Ip Degree Of Protection | IP20 |
Device Presentation | complete product |
Absolute Maximum Voltage | 600 V |
Dv/Dt | 500 V/µs off-state at maximum voltage |
Maximum Switching Voltage | 10 V AC turn-off |
Capacitance Unbalance | 8 pF for input/output |
Input Current Limits | 5-10 mA |
Protection Device Type | type 1 - 40 A miniature circuit breaker (MCB) B || type 2 - 32 A miniature circuit breaker (MCB) B |
[Uc] Control Circuit Voltage | 90...280 V AC |
Output Voltage | 24...300 V AC |
Maximum Horse Power Rating | 0.75 hp 120 V AC || 2 hp 240 V AC |
Tightening Torque | 1.5...1.7 N.m for input || 2...2.2 N.m for output |
Insulation Resistance | 1000 MOhm at 500 V DC |
Thermal Resitance | 0.45 °C/W junction to case |
Maximum I²T For Fusing | 1621 A².s for 8.33 ms at 60 Hz || 1770 A².s for 10 ms at 50 Hz |
Offer Sustainability | |
Rohs Exemption Information | Yes |
Mercury Free | Yes |
Environmental Disclosure | ENVPEP1505006EN |
Sustainable Offer Status | Green Premium product |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
China Rohs Regulation | X |
Circularity Profile | ENVEOLI1505006EN |
Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Environment | |
Product Certifications | UL || CSA || CE || EAC |
Ambient Air Temperature For Operation | -40-80 °C |
Standards | UL 508 || CSA C22.2 No 14-13 || EN/IEC 60950-1 || EN/IEC 62314 |
Pollution Degree | 2 |
Marking | CE || UL || CSA || EAC |
Ambient Air Temperature For Storage | -40-125 °C |
Overvoltage Category | III |