Contact block, Harmony XAC, single contact, spring return, front mounting, 40mm horizontal/30mmVertical fixing centres, 2NC
- Manufactured by:
- Schneider Electric
- Price (VAT excluded)
- € 17.20
- Nuova Elva code
- XACS414
- Manufacturer code
- XACS414
- Availability
- Standard lead time: 7 days
This spring return contact block is a separate component for double insulated, XACB pendant control station. It is designed for front mounting and features 2 NC contacts.
Specifications
Net Weight | 0.07 kg |
---|---|
Standard | CSA C22.2 No 14 |
Storage Temperature | -40-70 °C |
Warranty Length | 18 months |
Specifications | |
Mounting Of Block | front mounting |
Component Name | XACS |
Product Compatibility | ZA2B... head || XACA |
Contacts Type And Composition | 2 NC |
Range Of Product | Harmony XAC |
Contact Operation | slow-break |
Mechanical Interlocking | without mechanical interlock |
Type Of Operator | spring return |
Contact Block Type | single |
Electrical Circuit Type | control circuit |
Product Or Component Type | contact block |
Contractual warranty | |
Warranty | 18 months |
Complementary | |
Vertical Fixing Centres | 30 mm |
[Ithe] Conventional Enclosed Thermal Current | 10 A |
Short-Circuit Protection | 10 A fuse protection cartridge gG |
Contact Code Designation | A300 AC-15, Ue = 240 V, Ie = 3 A IEC 60947-5-1 appendix A || Q300 DC-13, Ue = 250 V, Ie = 0.27 A IEC 60947-5-1 appendix A |
Net Weight | 0.07 kg |
Rated Operational Power In W | 42 W DC-13 1000000 cycles 60 cyc/mn 120 V 0.5 inductive IEC 60947-5-1 appendix C || 45 W DC-13 1000000 cycles 60 cyc/mn 48 V 0.5 inductive IEC 60947-5-1 appendix C || 60 W DC-13 1000000 cycles 60 cyc/mn 24 V 0.5 inductive IEC 60947-5-1 appendix C |
[Uimp] Rated Impulse Withstand Voltage | 6 kV IEC 60947-1 |
Terminal Identifier | (13-14)NO || (11-12)NC |
Connections - Terminals | screw clamp terminals, 1 x 2.5 mm² with or without cable end || screw clamp terminals, 2 x 1.5 mm² with or without cable end |
Terminals Description Iso N°1 | (21-22)NC || (11-12)NC |
[Ui] Rated Insulation Voltage | 500 V 3)IEC 60947-1 |
Rated Operational Power In Va | 140 VA AC-15 1000000 cycles 60 cyc/mn 24 V 50/60 Hz 0.5 inductive || 385 VA AC-15 1000000 cycles 60 cyc/mn 48 V 50/60 Hz 0.5 inductive || 455 VA AC-15 1000000 cycles 60 cyc/mn 230 V 50/60 Hz 0.5 inductive || 525 VA AC-15 1000000 cycles 60 cyc/mn 127 V 50/60 Hz 0.5 inductive |
Maximum Resistance Across Terminals | 25 MOhm |
Mechanical Durability | 1000000 cycles |
Horizontal Fixing Centres | 40 mm |
Offer Sustainability | |
China Rohs Regulation | X |
Rohs Exemption Information | Yes |
Mercury Free | Yes |
Toxic Heavy Metal Free | Yes |
Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Reach Regulation | Free of Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Reach Free Of Svhc | Yes |
Weee | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
Environment | |
Ambient Air Temperature For Operation | -25-70 °C |
Ambient Air Temperature For Storage | -40-70 °C |
Standards | CSA C22.2 No 14 || IEC 60947-5-1 || EN 60947-5-1 |
Shock Resistance | 100 gn IEC 60068-2-27 |
Vibration Resistance | 15 gn 10-500 Hz)IEC 60068-2-6 |