Harmony XB4, Illuminated double-headed push button, metal, Ø22, 1 green flush I + 1 pilot light + 1 red projecting O, 1 NO + 1 NC
- Manufactured by:
- Schneider Electric
- Price (VAT excluded)
- € 43.34
- Nuova Elva code
- XB4BW73731B5
- Manufacturer code
- XB4BW73731B5
- Availability
- 13 in stock
This Harmony XB4 double-headed modular push button has 1 red, 1 green button and 1 central white pilot light, operates with a spring return mechanism, is supplied with 24V AC/DC. It has a metal bezel. It is marked with "I" and "O" symbols. This illuminated push button provides an ergonomic and visual interface for controlling your machines. It is easily installed into standard 22mm diameter panel cut-outs and connected to control circuits with classic screw-clamp connections. It is clearly distinguishable visually at a distance thanks to a bright and long lasting LED illumination. It is impact resistant, dust resistant, water resistant and vibration resistant thanks to its IP66 / IP67 / IP69 / IP69K, making it ideal for operation in harsh environments.
Specifications
Bezel Material | Chromium Plated Metal |
---|---|
Certifications | BV |
Contact Material | Silver Alloy |
Current | 18 mA |
Net Weight | 0.13 kg |
Standard | CSA C22.2 No 14 |
Storage Temperature | -40-70 °C |
Warranty Length | 18 months |
Specifications | |
Range Of Product | Harmony XB4 |
Device Short Name | XB4 |
Light Source | protected LED |
Mounting Diameter | 22 mm |
Product Or Component Type | illuminated double-headed push-button |
Colour Of Marking | white marking when green, red or black caps || black marking when white caps |
Head Type | standard |
Device Presentation | complete product |
Bezel Material | chromium plated metal |
Light Source Colour | white |
Contractual warranty | |
Warranty | 18 months |
Complementary | |
Contacts Usage | standard contacts |
Shape Of Signaling Unit Head | rectangular |
Net Weight | 0.13 kg |
[Uimp] Rated Impulse Withstand Voltage | 6 kV EN 60947-1 |
Current Consumption | 18 mA |
Fixing Collar Material | zamak |
Operator Profile | 1 flush - 1 projecting push-buttons - 1 central pilot light |
Resistance To High Pressure Washer | 7000000 Pa 55 °C 0.1 m |
Electrical Durability | 1000000 cycles, AC-15, 2 A 230 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C || 1000000 cycles, AC-15, 3 A 120 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C || 1000000 cycles, AC-15, 4 A 24 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C || 1000000 cycles, DC-13, 0.2 A 110 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C || 1000000 cycles, DC-13, 0.5 A 24 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C |
Connections - Terminals | screw clamp terminals, <= 2 x 1.5 mm² with cable end EN/IEC 60947-1 || screw clamp terminals, >= 1 x 0.22 mm² without cable end EN/IEC 60947-1 |
Contacts Type And Composition | 1 NO + 1 NC |
Short-Circuit Protection | 10 A cartridge fuse gG EN/IEC 60947-5-1 |
Service Life | 100000 h at rated voltage and 25 °C |
Surge Withstand | 1 kV IEC 61000-4-5 |
[Ui] Rated Insulation Voltage | 600 V 3)EN 60947-1 |
Signalling Type | steady |
[Ie] Rated Operational Current | 3 A 240 V, AC-15, A600 EN/IEC 60947-5-1 || 6 A 120 V, AC-15, A600 EN/IEC 60947-5-1 || 0.1 A 600 V, DC-13, Q600 EN/IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q600 EN/IEC 60947-5-1 || 0.55 A 125 V, DC-13, Q600 EN/IEC 60947-5-1 || 1.2 A 600 V, AC-15, A600 EN/IEC 60947-5-1 |
Contact Operation | slow-break |
Supply Voltage Limits | 19.2-30 V DC || 21.6-26.4 V AC |
Operator Profile | green flush, I white) || red projecting, O white) |
Mechanical Durability | 1000000 cycles |
Compatibility Code | XB4 |
Operating Force | 3.5 N NC changing electrical state || 3.8 N NO changing electrical state |
Electrical Reliability | λ < 10exp(-6) 5 V 1 mA in clean environment EN/IEC 60947-5-4 || λ < 10exp(-8) 17 V 5 mA in clean environment EN/IEC 60947-5-4 |
Tightening Torque | 0.8-1.2 N.m EN 60947-1 |
Shape Of Screw Head | cross JIS No 1 || cross Philips no 1 || cross pozidriv No 1 || slotted flat Ø 4 mm || slotted flat Ø 5.5 mm |
[Us] Rated Supply Voltage | 24 V AC/DC 50/60 Hz |
Bulb Base | integral LED |
Operating Travel | 1.5 mm NC changing electrical state) || 2.6 mm NO changing electrical state) || 4.3 mm total travel) |
Contacts Material | silver alloy (Ag/Ni) |
Positive Opening | with EN/IEC 60947-5-1 appendix K |
Type Of Operator | spring return |
Operators Description | green ''I'' - red ''O'' |
[Ith] Conventional Free Air Thermal Current | 10 A EN/IEC 60947-5-1 |
Offer Sustainability | |
Rohs Exemption Information | Yes |
Circularity Profile | ENVEOLI1808008EN |
Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Mercury Free | Yes |
Environmental Disclosure | ENVPEP1808008EN |
Sustainable Offer Status | Green Premium product |
Reach Regulation | Free of Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Reach Free Of Svhc | Yes |
Weee | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins. |
China Rohs Regulation | X |
Environment | |
Product Certifications | DNV || LROS (Lloyds register of shipping) || CSA || BV || UL Listed || GL |
Nema Degree Of Protection | NEMA 13 || NEMA 4X |
Resistance To Electrostatic Discharge | 6 kV on contact (on metal parts) IEC 61000-4-2 || 8 kV in free air (in insulating parts) IEC 61000-4-2 |
Electrical Shock Protection Class | class I IEC 60536 |
Protective Treatment | TH |
Resistance To Fast Transients | 2 kV IEC 61000-4-4 |
Electromagnetic Emission | class B IEC 55011 |
Ik Degree Of Protection | IK06 IEC 50102 |
Ambient Air Temperature For Operation | -40-70 °C |
Resistance To Electromagnetic Fields | 10 V/m IEC 61000-4-3 |
Standards | EN/IEC 60947-1 || EN/IEC 60947-5-1 || CSA C22.2 No 14 || JIS C8201-5-1 || EN/IEC 60947-5-5 || EN/IEC 60947-5-4 || UL 508 || JIS C8201-1 |
Shock Resistance | 30 gn 18 ms) half sine wave acceleration IEC 60068-2-27 || 50 gn 11 ms) half sine wave acceleration IEC 60068-2-27 |
Vibration Resistance | 5 gn 2-500 Hz)IEC 60068-2-6 |
Ip Degree Of Protection | IP66 IEC 60529 || IP69K IEC 60529 || IP69 IEC 60529 |
Ambient Air Temperature For Storage | -40-70 °C |