Limit switch, Limit switches XC Standard, XCKD, metal end plunger, 1NC+1 NO, snap, Pg11

Manufactured by:
Schneider Electric
Schneider electric

2826dbc508bc4b2d2086747c5696c9817a367638 medium
Price (VAT excluded)
€ 25.83
Nuova Elva code
XCKD2110G11
Manufacturer code
XCKD2110G11
Availability
Send request for quotation

This XCKD compact format (CENELEC EN 50047) limit switch has a metal end plunger and a Zamak body. This limit switch has a robust Zamak body and head, a modular design allowing easier maintenance and a compact CENELEC EN50047 format. It is ideal for all industrial machines like packaging, materials handling, conveyors, machining, food and beverage. It is fixed on the machine by its body, and has a typical 5 million cycles electrical durability in DC-13 utilization category. It complies with CCC, EN/IEC 60947.-5-1, CSA C22.2 No.14, EN/IEC 60204-1, UL 508 standards and is also RoHS compliant. Compatible with the well distributed range of common XCK heads, allowing quick replacement in case of damage. Variable composition design allows late modifications on the switch, for example change of connection type or head.

Specifications

CertificationsCCC
Depth30 mm
Height65-65 mm
MaterialMetal
Net Weight0.18 kg
Number of Poles2
StandardCSA C22.2 No 14
Storage Temperature-40-70 °C
Warranty Length18 months
Width31 mm

Specifications

Movement Of Operating Headlinear
Type Of Approachvertical approach, 1 direction
Series Namestandard format
Contacts Type And Composition1 NC + 1 NO
Body Typefixed
Contact Operationsnap action
Body Materialzamak
Device Short NameXCKD
Number Of Poles2
Range Of ProductTelemecanique Limit switches XC Standard
Fixing Modeby the body
Type Of Operatorspring return plunger metal
Sensor Designcompact form B CENELEC EN 50047
Product Or Component Typelimit switch
Head Materialzamak
Materialmetal
Head Typeplunger head

Contractual warranty

Warranty18 months

Complementary

Height65-65 mm
[Ui] Rated Insulation Voltage300 VUL 508 || 500 V 3)IEC 60947-1 || 300 VCSA C22.2 No 14
Electrical Durability5000000 cycles, DC-13, 120 V, 4 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, 24 V, 10 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, 48 V, 7 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
Positive Opening Minimum Force45 N
Positive Openingwith
Contacts Insulation FormZb
Mechanical Durability15000000 cycles
Maximum Actuation Speed0.5 m/s
Minimum Force For Tripping15 N
Contact Code DesignationA300, AC-15 (Ue = 240 V), Ie = 3 A 10 A EN 60947-5-1 || A300, AC-15 (Ue = 240 V), Ie = 3 A 10 A IEC 60947-5-1 appendix A || Q300, DC-13 (Ue = 250 V), Ie = 0.27 A EN 60947-5-1 || Q300, DC-13 (Ue = 250 V), Ie = 0.27 A IEC 60947-5-1 appendix A
Width31 mm
Terminals Description Iso N°1(21-22)NC || (13-14)NO
Depth30 mm
Repeat Accuracy0.1 mm on the tripping points with 1 million operating cycles
Maximum Resistance Across Terminals25 MOhm IEC 60255-7 category 3
Short-Circuit Protection10 A cartridge fuse gG
Minimum Actuation Speed0.01 m/min
Electrical Connectionscrew-clamp terminals 1 x 0.34...2 x 1.5 mm²
Cable Entry1 entry tapped for Pg 11 cable gland
Net Weight0.18 kg
[Uimp] Rated Impulse Withstand Voltage6 kV IEC 60664 || 6 kV IEC 60947-1
Switch Actuationon end

Offer Sustainability

Rohs Exemption InformationYes
Mercury FreeYes
Environmental DisclosureENVPEP110614EN
Sustainable Offer StatusGreen Premium product
Reach RegulationReference contains Substances of Very High Concern above the threshold
California Proposition 65WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)

Environment

Product CertificationsUL || CCC || CSA
Protective TreatmentTC
Ik Degree Of ProtectionIK06 EN 50102
Ambient Air Temperature For Operation-25-70 °C
StandardsEN 60947-5-1 || UL 508 || IEC 60204-1 || EN 60204-1 || IEC 60947-5-1 || CSA C22.2 No 14
Ip Degree Of ProtectionIP66IEC 60529 || IP67IEC 60529
Shock Resistance50 gn 11 ms IEC 60068-2-27
Vibration Resistance25 gn 10-500 Hz)IEC 60068-2-6
Ambient Air Temperature For Storage-40-70 °C
Electrical Shock Protection Classclass I IEC 61140 || class I NF C 20-030