Limit switch, Limit switches XC Standard, XCR, metal stay put T rods lever square rod 6 mm, 2X(1NC+NO)

Manufactured by:
Schneider Electric
Schneider electric

4fd5a697f424ffb2196d4b01cfe02f0b87cd757a medium
Price (VAT excluded)
€ 227.39
Nuova Elva code
XCRF17
Manufacturer code
XCRF17
Availability
Send request for quotation

This product is part of the XC Special range, an offer of limit switches. This limit switch is a device that converts a mechanical motion into an electrical control signal. It has 2 x (1 normally closed + 1 normally opened), snap action contacts with positive opening operation and provides switch actuation by any moving part. It has a metal square rods lever stay put crossed and supports lateral approach in 2 directions. The movement of operating head is rotary. It is furnished with screw clamp terminals for electrical connection and 1 entry tapped for PG13.5 cable gland. It is an IP54 rated product. It has a rated operational current of 3A at 240V AC, 0.27A at 250V AC and a conventional enclosed thermal current of 10A. Its mechanical durability is about 10 million operating cycles, electrical durability is 5 million operating cycles. This limit switch has a fixed type body which is made of zinc alloy. Its dimensions are 85mm (Width) x 75mm (Depth) x 95mm (Height) and weighs 1.135kg. It is suitable for hoisting and mechanical handling applications. This product is certified by CCC and CSA. It meets NF C 79-130, CSA C22.2 No 14, EN 60947-5-1, EN 60204-1, IEC 60204-1 and IEC 60947-5-1 standards. Special format limit switches for severe environments.

Specifications

CertificationsCCC
Depth75 mm
Height95-95 mm
MaterialMetal
Net Weight1.135 kg
Number of Poles4
Number of Steps1
StandardCSA C22.2 No 14
Storage Temperature-40-70 °C
Warranty Length18 months
Width85 mm

Specifications

Movement Of Operating Headrotary
Type Of Approachlateral approach, 2 directions
Series Namespecial format
Contacts Type And Composition2 x (1 NC + 1 NO)
Body Typefixed
Positive Openingwith
Contact Block Per Direction [Control Circuit]1 per direction
Contact Operationsnap action
Product Specific Applicationfor hoisting and mechanical handling applications
Device Short NameXCR
Number Of Poles4
Range Of ProductOsiSense XC
Electrical Connectionscrew-clamp terminals 1 x 0.34...2 x 1.5 mm²
Fixing Modeby the body
Type Of Operatorstay put crossed rods lever metal square rod 6 mm
Product Or Component Typelimit switch
Materialmetal
Head Typerotary head

Contractual warranty

Warranty18 months

Complementary

Maximum Displacement Angle-90 ° || 90 °
Switch Actuationby any moving part
[Ui] Rated Insulation Voltage300 VUL 508 || 500 V 3)IEC 60947-1 || 500 V 3)VDE 0110 || 300 VCSA C22.2 No 14
Electrical Durability5000000 cycles, DC-13, inductive, 120 V, 4 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, inductive, 24 V, 7 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, inductive, 48 V, 10 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
Contacts Insulation FormZb
Positive Opening Minimum Torque0.7 N.m
Mechanical Durability10000000 cycles
Maximum Actuation Speed1.5 m/s
Body Materialzinc alloy
Contact Code DesignationA300, AC-15 (Ue = 240 V), Ie = 3 A EN/IEC 60947-5-1 appendix A || Q300, DC-13 (Ue = 250 V), Ie = 0.27 A EN/IEC 60947-5-1 appendix A
Width85 mm
Height95-95 mm
Depth75 mm
Minimum Torque For Tripping0.6 N.m
Maximum Resistance Across Terminals25 MOhm IEC 60255-7 category 3
Terminals Description Iso N°1(13-14)NO || (21-22)NC
Short-Circuit Protection10 A cartridge fuse gG
Minimum Actuation Speed0.01 m/min
Number Of Steps1
Cable Entry1 entry tapped for Pg 13.5 cable gland 9-12 mm NF C 68-300
Net Weight1.135 kg
[Uimp] Rated Impulse Withstand Voltage6 kV IEC 60664 || 6 kV IEC 60947-1

Offer Sustainability

Rohs Exemption InformationYes
Mercury FreeYes
Environmental DisclosureENVPEP111136EN
Sustainable Offer StatusGreen Premium product
Reach RegulationReference contains Substances of Very High Concern above the threshold
California Proposition 65WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)

Environment

Product CertificationsCCC || CSA
Ambient Air Temperature For Operation-25-70 °C
StandardsEN 60204-1 || IEC 60204-1 || IEC 60947-5-1 || CSA C22.2 No 14 || NF C 79-130 || EN 60947-5-1
Shock Resistance68 gn IEC 60068-2-27
Vibration Resistance9 gn 10-500 Hz)IEC 60068-2-6
Ip Degree Of ProtectionIP54 conforming to IEC 60529
Ambient Air Temperature For Storage-40-70 °C
Overvoltage Categoryclass I IEC 61140 || class I NF C 20-030
Protective TreatmentTC

Docs


Frequently bought together


Other Schneider Electric items

Request a quote