[Us] Rated Supply Voltage | 24 V - 20...10 % |
---|
Electromagnet Interlocking | locking on de-energisation and unlocking on energisation of solenoid |
---|
Product Or Component Type | safety switch |
---|
Signalling Circuit Voltage | 24/48 V 20...52 V) |
---|
Component Name | XCSE |
---|
Cable Outer Diameter | 9-12 mm |
---|
Material | metal |
---|
Design | rectangular |
---|
Number Of Poles | 3 |
---|
Head Type | key operated turret head |
---|
Contacts Type And Composition | 2 NC + 1 NO |
---|
Range Of Product | Telemecanique Safety switches XCS |
---|
Cable Entry | 2 entries tapped Pg 13.5 |
---|
Electrical Connection | terminal 1 x 0.5...2 x 1.5 mm² with or without cable end |
---|
Locking Options Description | with interlocking, locking by solenoid |
---|
Contact Operation | slow-break, break before make |
---|
Local Signalling | for guard open/guard closed and locked 2 LEDs (green or orange) |
---|
Solenoid Contacts Type And Composition | 1 NC + 1 NO slow-break, simultaneous) |
---|
Height | 146-146 mm |
---|
Minimum Actuator Force For Extraction | 20 N |
---|
Mechanical Durability | 1000000 cycles |
---|
Maximum Actuation Speed | 0.5 m/s |
---|
Body Material | zamak |
---|
[Ithe] Conventional Enclosed Thermal Current | 6 A |
---|
Safety Reliability Data | B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear |
---|
Power Consumption In Va | 10 VA inrush || 10 VA sealed |
---|
Supply Voltage Type | AC/DC |
---|
Width | 98 mm |
---|
Actuator Forcible Withdrawal Rtc | 2000 N |
---|
Maximum Operating Rate | 10 cyc/mn for maximum durability |
---|
Depth | 44 mm |
---|
Head Material | zamak |
---|
Signalling Circuit Type | AC/DC |
---|
Protection Type | overvoltage protection signalling circuit |
---|
Net Weight | 1.14 kg |
---|
[Uimp] Rated Impulse Withstand Voltage | 6 kV EN/IEC 60947-5-1 |
---|
Supply Frequency | 50/60 Hz |
---|
Safety Level | can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508 |
---|
[Ui] Rated Insulation Voltage | 50 VEN/IEC 60947-1 signalling circuit |
---|
Short-Circuit Protection | 10 A cartridge fuse gG (gl) |
---|
Positive Opening | with NC contact |
---|
Load Factor | 1 |
---|
Minimum Actuation Speed | 0.01 m/s |
---|
[Ie] Rated Operational Current | 0.55 A 125 V, DC-13, Q300 EN/IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 || 3 A 120 V, AC-15, B300 EN/IEC 60947-5-1 || 1.5 A 240 V, AC-15, B300 EN/IEC 60947-5-1 |
---|
Signalling Circuit Consumption | 7 mA |
---|