Safety switch, Telemecanique Safety switches XCS, metal 2NC + 1 NO, slow break, 2 entries tapped M20, 24 V
- Manufactured by:
- Schneider Electric
- Price (VAT excluded)
- € 426.92
- Nuova Elva code
- XCSE7412
- Manufacturer code
- XCSE7412
- Availability
- Send request for quotation
This product is part of the XCS range, an offer of safety switches. The safety switch is an electrical switch that makes or breaks contact in the presence of a magnetic field. It has 2 normally closed + 1 normally opened, slow break contacts, normally closed contact with positive opening operation. It is a switch with a rated operational current of 1.5A at 240V AC, 3A at 120V AC, 0.27A at 250V DC, 0.55 at 125V DC and a conventional enclosed thermal current of 6A. It is designed to operate in hazardous environments. It is furnished with screw clamp terminals for electrical connection and 2 cable entry tapped for M20 x 1.5 cable gland. The electromagnet interlocking by solenoid. It offers long mechanical durability which is about 1 million operating cycles. It is an IP67 rated product. The key operated turret head limit switch has a rectangular metal body which is made of Zamak. Its dimensions are 98mm (Width) x 44mm (Depth) x 146mm (Height) and weighs 1.14kg. It is intended as far as safety is concerned all dangerous machines in all sectors are involved. Such as packaging, handling, robotics, machine tools, presses, automotive sector. This product is certified by UL, CSA and TUV. It meets CSA C22.2 No 14, EN 60947-5-1, EN/ISO 13849-1, EN/IEC 62061, EN 1088/ISO 14119 and UL 508 standards. One of the most comprehensive ranges of industrial safety switches on the market. These safety interlock switches are suitable for protecting operators of potentially dangerous machines with inertia. Safety switches for the protection of operators, by controlling the safe opening and interlocking of guards and covers in your installations.
Specifications
Certifications | CSA |
---|---|
Chain/Cable Diameter | 9-12 mm |
Depth | 44 mm |
Height | 146-146 mm |
Material | Metal |
Net Weight | 1.14 kg |
Number of Poles | 3 |
Standard | CSA C22.2 No 14 |
Storage Temperature | -40-70 °C |
Width | 98 mm |
Specifications | |
[Us] Rated Supply Voltage | 24 V - 20...10 % |
Material | metal |
Design | rectangular |
Head Type | key operated turret head |
Contacts Type And Composition | 2 NC + 1 NO |
Contact Operation | slow-break, break before make |
Local Signalling | for guard open/guard closed and locked 2 LEDs (green or orange) |
Cable Outer Diameter | 9-12 mm |
Number Of Poles | 3 |
Range Of Product | Telemecanique Safety switches XCS |
Cable Entry | 2 entries tapped M20 x 1.5 |
Electrical Connection | terminal 1 x 0.5...2 x 1.5 mm² with or without cable end |
Locking Options Description | with interlocking, locking by solenoid |
Solenoid Contacts Type And Composition | 1 NC + 1 NO slow-break, simultaneous) |
Product Or Component Type | safety switch |
Signalling Circuit Voltage | 24/48 V 20...52 V) |
Component Name | XCSE |
Complementary | |
Height | 146-146 mm |
Net Weight | 1.14 kg |
[Uimp] Rated Impulse Withstand Voltage | 6 kV EN/IEC 60947-5-1 |
Maximum Operating Rate | 10 cyc/mn for maximum durability |
[Ui] Rated Insulation Voltage | 50 VEN/IEC 60947-1 signalling circuit |
Positive Opening | with NC contact |
Load Factor | 1 |
[Ie] Rated Operational Current | 0.55 A 125 V, DC-13, Q300 EN/IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 || 3 A 120 V, AC-15, B300 EN/IEC 60947-5-1 || 1.5 A 240 V, AC-15, B300 EN/IEC 60947-5-1 |
Minimum Actuator Force For Extraction | 20 N |
Mechanical Durability | 1000000 cycles |
Maximum Actuation Speed | 0.5 m/s |
Short-Circuit Protection | 10 A cartridge fuse gG (gl) |
Body Material | zamak |
Safety Reliability Data | B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear |
Width | 98 mm |
Actuator Forcible Withdrawal Rtc | 2000 N |
Depth | 44 mm |
Protection Type | overvoltage protection signalling circuit |
Supply Frequency | 50/60 Hz |
Safety Level | can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508 |
Minimum Actuation Speed | 0.01 m/s |
Signalling Circuit Consumption | 7 mA |
[Ithe] Conventional Enclosed Thermal Current | 6 A |
Power Consumption In Va | 10 VA inrush || 10 VA sealed |
Supply Voltage Type | AC/DC |
Head Material | zamak |
Signalling Circuit Type | AC/DC |
Offer Sustainability | |
Rohs Exemption Information | Yes |
Mercury Free | Yes |
Environmental Disclosure | ENVPEP110916EN |
Sustainable Offer Status | Green Premium product |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Circularity Profile | ENVEOLI110903EN |
Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Environment | |
Product Certifications | UL || CSA |
Ambient Air Temperature For Operation | -25-40 °C |
Standards | CSA C22.2 No 14 || EN/ISO 12100 || EN/IEC 60947-5-1 || EN/IEC 60204-1 || UL 508 || EN 1088/ISO 14119 |
Shock Resistance | 10 gn 11 ms IEC 60068-2-27 |
Vibration Resistance | 5 gn 10-500 Hz)IEC 60068-2-6 |
Ip Degree Of Protection | IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1 |
Ambient Air Temperature For Storage | -40-70 °C |
Electrical Shock Protection Class | class I EN/IEC 61140 |
Protective Treatment | TC |