This XCSLF Key Operated Safety Switch for guard doors with locking by solenoid has an adjustable turret head and a robust red coated slim Zamak body with 3 x M20 cable gland entries, allowing for flexible installation. It has 1 normally open and 2 normally closed break-before-make (slow break) main contacts actuated by key, contact states given when the key is inserted. And it has 1 normally open and 2 normally closed auxiliary contacts actuated by the solenoid, contact states given when the solenoid is not powered. Its B10D reliability data is 5 500 000. Its IP66 degree of protection makes it ideal for heavy duty use in harsh conditions. It also complies with EN/ISO 14119, EN/IEC 60204-1, EN/IEC 60947-5-1, UL 508, CSA C22.2 No 14 standards. When associated and correctly connected to an appropriate safety control unit, it conforms to Category 4, performance level PL e, SIL 3 as described in EN/ISO 13849-1, EN/IEC 61508.

Specifications

CertificationsCSA
Chain/Cable Diameter7-13 mm
Depth113 mm
Height205-205 mm
MaterialMetal
Net Weight1.2 kg
Number of Poles3
StandardCSA C22.2 No 14
Storage Temperature-40-70 °C
Warranty Length18 months
Width44 mm

Specifications

[Us] Rated Supply Voltage24 V - 15...10 %
Designslim
Materialmetal
Head Typekey operated turret head
Contacts Type And Composition2 NC + 1 NO
Contact Operationslow-break, break before make
Local Signallingfor actuator withdrawn 1 LED (orange) || for actuator inserted and locked 1 LED (green)
Electromagnet Interlockinglocking on de-energisation and unlocking on energisation of solenoid || by mushroom head push-button turn to release for escape release
Cable Outer Diameter7-13 mm
Number Of Poles3
Range Of ProductTelemecanique Safety switches XCS
Cable Entry3 entries tapped M20 x 1.5
Electrical Connectionspring terminal 1 x 1.5 mm² flexible or solid cable || spring terminal 2 x 0.5 mm² flexible cables with 13 mm bared ends
Locking Options Descriptionwith interlocking, locking by solenoid
Solenoid Contacts Type And Composition2 NC + 1 NO slow-break, break before make)
Product Or Component Typesafety switch
Signalling Circuit Voltage24 V
Component NameXCSLF

Contractual warranty

Warranty18 months

Complementary

Minimum Switching Current10 mA at 20 °C
Net Weight1.2 kg
[Uimp] Rated Impulse Withstand Voltage4 kV EN/IEC 60947-5-1
Maximum Operating Rate10 cyc/mn for maximum durability
[Ui] Rated Insulation Voltage300 VUL 508 || 300 VCSA C22.2 No 14 || 250 V 3)EN/IEC 60947-1
Positive Openingwith NC contact
Load Factor1
[Ie] Rated Operational Current0.55 A 24 V, DC-13, R300 EN/IEC 60947-5-1 || 0.75 A 240 V, AC-15, C300 EN/IEC 60947-5-1
Minimum Actuator Force For Extraction20 N
Mechanical Durability30000 cycles
Maximum Actuation Speed0.5 m/s
Height205-205 mm
Body Materialzamak
Safety Reliability DataB10d = 5500000 value given for a life time of 20 years limited by mechanical or contact wear
Width44 mm
Depth113 mm
Minimum Switching Voltage17 V
Maximum Actuator Forcible Withdrawal Rtc3000 N
Resistance To Mechanical Impact9.6 J against the partition || 6.4 J without partition
Supply Frequency50/60 Hz
Safety Levelcan reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 EN/IEC 61508
Maximum Load Current<= 15 A
Short-Circuit Protection4 A cartridge fuse gG (gl) || 6 A fast blow
Minimum Actuation Speed0.01 m/s
[Ithe] Conventional Enclosed Thermal Current4 A
Supply Voltage TypeAC/DC
Head Materialzamak
Signalling Circuit TypeAC/DC

Offer Sustainability

Rohs Exemption InformationYes
Mercury FreeYes
Environmental DisclosureENVPEP110916EN
Sustainable Offer StatusGreen Premium product
Reach RegulationReference contains Substances of Very High Concern above the threshold
California Proposition 65WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Circularity ProfileENVEOLI110903EN
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)

Environment

Product CertificationsCSA || TÜV || UL
Ambient Air Temperature For Operation-25-60 °C
StandardsUL 508 || EN 1088/ISO 14119 || EN/IEC 62061 || EN/IEC 60204-1 || CSA C22.2 No 14 || EN/IEC 60947-5-1 || EN/ISO 13849-1
Shock Resistance10 gn 11 ms IEC 60068-2-27
Vibration Resistance5 gn 10-500 Hz)IEC 60068-2-6
Ip Degree Of ProtectionIP66 conforming to EN/IEC 60529 and EN/IEC 60947-5-1
Ambient Air Temperature For Storage-40-70 °C
Electrical Shock Protection Classclass I EN/IEC 61140
Protective TreatmentTC