Preventa XCS, safety switches, plastic safety switch, 1 NC and 1 NO, slow break, 1 entry tapped 0.5 inch NPT

Manufactured by:
Schneider Electric
Schneider%20electric

672659e5624a8d4fca0659b1ea8aa01fe2384fc5 medium
Price (VAT excluded)
€ 32.46
Nuova Elva code
XCSPA593
Manufacturer code
XCSPA593
Availability
Standard lead time: 9 days

Preventa safety switches are for controlling the safe opening and interlocking of guards and covers to installations. Protection of operators by stopping the machine when the actuator attached to the machine guard is withdrawn from the head of the switch. Preventa switches with metal housings are designed for heavy duty industrial machines with quick rundown time (key operated switches XCSA, XCSB, XCSC) or with slow rundown time (Key operated switches with solenoid XCSLF, XCSE). Preventa switches with plastic housings are designed for light industrial machines with quick rundown time (key operated switches XCSMP, XCSPA, XCSTA) or with slow rundown time (key operated switches with solenoid XCSLE, XCSTE). As far as safety is concerned all dangerous machines in all sectors are involved. Preventa safety switches can be used in packaging, handling, robotics, machine tools, presses, and automotive sectors. It secures the machine and system operation with a key, only available to authorized operators.

Specifications

CertificationsCSA
Depth30 mm
Height107-107 mm
MaterialPlastic
Net Weight0.11 kg
Number of Poles2
StandardCSA C22.2 No 14
Storage Temperature-40-70 °C
Warranty Length18 months
Width30 mm

Specifications

Range Of ProductTelemecanique Safety switches XCS
Contacts Type And Composition1 NC + 1 NO
Contact Operationslow-break, break before make
Number Of Poles2
Cable Entry1 entry tapped 1/2" NPT
Electrical Connectionterminal 1 x 0.5...2 x 1.5 mm² with or without cable end
Locking Options Descriptionwithout locking of actuator
Product Or Component Typesafety switch
Component NameXCSPA
Materialplastic
Designcompact
Head Typekey operated turret head

Contractual warranty

Warranty18 months

Complementary

Height107-107 mm
Positive Opening Minimum Force15 N
Insulationdouble insulated
Positive Openingwith NC contact
[Ie] Rated Operational Current6 A 120 V, AC-15, A300 EN/IEC 60947-5-1 || 3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 || 0.55 A 125 V, DC-13, Q300 EN/IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1
Mechanical Durability1000000 cycles
Maximum Actuation Speed0.5 m/s
Body MaterialPA (polyamide)
Safety Reliability DataB10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
Width30 mm
Actuator Forcible Withdrawal Rtc10 N
Short-Circuit Protection10 A cartridge fuse gG (gl)
Depth30 mm
Safety Levelcan reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508
Minimum Actuation Speed0.01 m/s
[Ithe] Conventional Enclosed Thermal Current10 A
Head MaterialPA (polyamide)
Net Weight0.11 kg
[Uimp] Rated Impulse Withstand Voltage6 kV EN/IEC 60947-5-1
Maximum Operating Rate10 cyc/mn for maximum durability
[Ui] Rated Insulation Voltage300 VUL 508 || 500 VEN/IEC 60947-1 || 300 VCSA C22.2 No 14

Offer Sustainability

Rohs Exemption InformationYes
Mercury FreeYes
Environmental DisclosureENVPEP110606EN
Sustainable Offer StatusGreen Premium product
Reach RegulationReference contains Substances of Very High Concern above the threshold
California Proposition 65WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Circularity ProfileENVEOLI110603EN
Eu Rohs DirectivePro-active compliance (Product out of EU RoHS legal scope)

Environment

Product CertificationsCSA || UL
Ambient Air Temperature For Operation-25-70 °C
StandardsEN/ISO 12100 || UL 508 || EN/IEC 60204-1 || EN 1088/ISO 14119 || EN/IEC 60947-5-1 || CSA C22.2 No 14
Shock Resistance10 gn 11 ms IEC 60068-2-27
Vibration Resistance5 gn 10-500 Hz)IEC 60068-2-6
Ip Degree Of ProtectionIP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1
Ambient Air Temperature For Storage-40-70 °C
Electrical Shock Protection Classclass II EN/IEC 61140
Protective TreatmentTC

Docs


Frequently bought together


Other Schneider Electric items

Request a quote