Preventa XCS, safety switches, plastic safety switch, 1 NC and 1 NO, slow break, 1 entry tapped 0.5 inch NPT
- Manufactured by:
- Schneider Electric
- Price (VAT excluded)
- € 32.46
- Nuova Elva code
- XCSPA593
- Manufacturer code
- XCSPA593
- Availability
- Standard lead time: 9 days
Preventa safety switches are for controlling the safe opening and interlocking of guards and covers to installations. Protection of operators by stopping the machine when the actuator attached to the machine guard is withdrawn from the head of the switch. Preventa switches with metal housings are designed for heavy duty industrial machines with quick rundown time (key operated switches XCSA, XCSB, XCSC) or with slow rundown time (Key operated switches with solenoid XCSLF, XCSE). Preventa switches with plastic housings are designed for light industrial machines with quick rundown time (key operated switches XCSMP, XCSPA, XCSTA) or with slow rundown time (key operated switches with solenoid XCSLE, XCSTE). As far as safety is concerned all dangerous machines in all sectors are involved. Preventa safety switches can be used in packaging, handling, robotics, machine tools, presses, and automotive sectors. It secures the machine and system operation with a key, only available to authorized operators.
Specifications
Certifications | CSA |
---|---|
Depth | 30 mm |
Height | 107-107 mm |
Material | Plastic |
Net Weight | 0.11 kg |
Number of Poles | 2 |
Standard | CSA C22.2 No 14 |
Storage Temperature | -40-70 °C |
Warranty Length | 18 months |
Width | 30 mm |
Specifications | |
Range Of Product | Telemecanique Safety switches XCS |
Contacts Type And Composition | 1 NC + 1 NO |
Contact Operation | slow-break, break before make |
Number Of Poles | 2 |
Cable Entry | 1 entry tapped 1/2" NPT |
Electrical Connection | terminal 1 x 0.5...2 x 1.5 mm² with or without cable end |
Locking Options Description | without locking of actuator |
Product Or Component Type | safety switch |
Component Name | XCSPA |
Material | plastic |
Design | compact |
Head Type | key operated turret head |
Contractual warranty | |
Warranty | 18 months |
Complementary | |
Height | 107-107 mm |
Positive Opening Minimum Force | 15 N |
Insulation | double insulated |
Positive Opening | with NC contact |
[Ie] Rated Operational Current | 6 A 120 V, AC-15, A300 EN/IEC 60947-5-1 || 3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 || 0.55 A 125 V, DC-13, Q300 EN/IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 |
Mechanical Durability | 1000000 cycles |
Maximum Actuation Speed | 0.5 m/s |
Body Material | PA (polyamide) |
Safety Reliability Data | B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear |
Width | 30 mm |
Actuator Forcible Withdrawal Rtc | 10 N |
Short-Circuit Protection | 10 A cartridge fuse gG (gl) |
Depth | 30 mm |
Safety Level | can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508 |
Minimum Actuation Speed | 0.01 m/s |
[Ithe] Conventional Enclosed Thermal Current | 10 A |
Head Material | PA (polyamide) |
Net Weight | 0.11 kg |
[Uimp] Rated Impulse Withstand Voltage | 6 kV EN/IEC 60947-5-1 |
Maximum Operating Rate | 10 cyc/mn for maximum durability |
[Ui] Rated Insulation Voltage | 300 VUL 508 || 500 VEN/IEC 60947-1 || 300 VCSA C22.2 No 14 |
Offer Sustainability | |
Rohs Exemption Information | Yes |
Mercury Free | Yes |
Environmental Disclosure | ENVPEP110606EN |
Sustainable Offer Status | Green Premium product |
Reach Regulation | Reference contains Substances of Very High Concern above the threshold |
California Proposition 65 | WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
Circularity Profile | ENVEOLI110603EN |
Eu Rohs Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
Environment | |
Product Certifications | CSA || UL |
Ambient Air Temperature For Operation | -25-70 °C |
Standards | EN/ISO 12100 || UL 508 || EN/IEC 60204-1 || EN 1088/ISO 14119 || EN/IEC 60947-5-1 || CSA C22.2 No 14 |
Shock Resistance | 10 gn 11 ms IEC 60068-2-27 |
Vibration Resistance | 5 gn 10-500 Hz)IEC 60068-2-6 |
Ip Degree Of Protection | IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1 |
Ambient Air Temperature For Storage | -40-70 °C |
Electrical Shock Protection Class | class II EN/IEC 61140 |
Protective Treatment | TC |